• Title/Summary/Keyword: Absolute Difference

Search Result 717, Processing Time 0.029 seconds

Impedance Changes of Living Tissue During Radiation Exposure Dose (방사선 피폭선량에 대한 생체 조직의 임피던스 변화)

  • Kil, Sang Hyeong;Lee, Moo Seok;Nam, Ji Ho;Lee, Yeong Hwa;Kim, Gun Do;Lee, Jong Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.202-207
    • /
    • 2013
  • Bioimpedance involves a lot of information related to living tissue. If there is alteration in bio tissue, its electrical characteristics also change. It is to study electrical characteristics of pork tenderlion in using a HP-4194A Impedance/Gain-phase analyzer instrument and electrical characteristics changes by graded radiation exposure dose. The results were as follow 1. Electrical characteristics of pork tenderlion in repeated measurement had high precision within ${\pm}5$% of coefficiency of variability. 2. During the measurement impedance absolute value and phase alteration did not show statistically significant difference.(p>0.05) 3. While impedance phase of electrical characteristics associated with frequency change was almost stable, impedance absolute value was in inverse proportion to frequency that means high inverse correlation of -0.096(r). 4. Impedance absolute value dropped in radiation exposure dose. The alteration of the value did not show statistically significant difference in 1 Gy, 2 Gy and 4 Gy.(p>0.05) However in radiation exposure dose of 10 Gy, the decrease of impedance absolute value was significantly different.(p<0.05) 5. Impedance phase according to radiation exposure dose change did not show statistically significant difference in 1 Gy, 2 Gy, 4 Gy, and 10 Gy(p>0.05).

Reduced-bit transform based block matching algorithm via SAD (영상의 저 비트 변환을 이용한 SAD 블록 정합 알고리즘)

  • Kim, Sang-Chul;Park, Soon-Yong;Chien, Sung-Il
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.107-115
    • /
    • 2014
  • The reduced-bit transform based bit-plane matching algorithm (BPM) can obtain the block matching result through its simple calculation and hardware design compared to the conventional block matching algorithms (BMAs), but the block matching accuracy of BPMs is somewhat low. In this paper, reduced-bit transform based sum of the absolute difference (R-SAD) is proposed to improve the block matching accuracy in comparison with the conventional BPMs and it is shown that the matching process can be obtained using the logical operations. Firstly, this method transforms the current and the reference images into their respective 2-bit images and then a truth table is obtained from the relation between input and output 2-bit images. Next, a truth table is simplified by Karnaugh map and the absolute difference is calculated by using simple logical operations. Finally, the simulation results show that the proposed R-SAD can obtain higher accuracy in block matching results compared to the conventional BPMs through the PSNR analysis in the motion compensation experiments.

A Study on the Effect Analysis Influenced on the Advanced System of Moving Object (이동물체가 정밀 시스템에 미치는 영항분석에 관한 연구)

  • Shin, Hyeon-Jae;Kim, Soo-In;Choi, In-Ho;Shon, Young-Woo;An, Young-Hwan;Kim, Dae-Wook;Lee, Jae-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.87-95
    • /
    • 2007
  • In this paper, we analyzed the mr detection and the stability of the object tracking system by an adaptive stereo object hacking using region-based MAD(Mean Absolute Difference) algorithm and the modified PID(Proportional Integral Derivative)-based pan/tilt controller. That is, in the proposed system, the location coordinates of the target object in the right and left images are extracted from the sequential stereo input image by applying a region-based MAD algorithm and the configuration parameter of the stereo camera, and then these values could effectively control to pan/tilt of the stereo camera under the noisy circumstances through the modified PID controller. Accordingly, an adaptive control effect of a moving object can be analyzed through the advanced system with the proposed 3D robot vision, in which the possibility of real-time implementation of the robot vision system is also confirmed.

Fast Black Matching Algorithm Using The Lower and Upper Bound of Mean Absolute Difference (블록 평균 절대치 오차의 최소 및 최대 범위를 이용한 고속 블록 정합 알고리듬)

  • 이법기;정원식;이경환;최정현;김경규;김덕규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.9A
    • /
    • pp.1401-1410
    • /
    • 1999
  • In this paper, we propose a fast block matching algorithm using the lower and upper bound of mean absolute difference (MAD) which is calculated at the search region overlapped with neighbor blocks. At first, we calculate the lower bound of MAD and reduce the search point by using this lower bound. In this method, we can get good prediction error performance close to full search block matching algorithm (FSBMA), but there exists some computational complexity that has to be reduced. Therefore, we further reduce the computational complexity by using pixel subsampling besides the lower and upper bound of MAD. Experimental results show that we can remarkably reduce the computational complexity with good prediction error performance close to FSBMA.

  • PDF

Comparison of the Diagnostic Validity of Real and Absolute Skin Temperature Differences for Complex Regional Pain Syndrome (복합부위통증증후군 진단 시 좌우 체온 차이의 실제값과 절대값의 진단적 타당도 비교)

  • Nahm, Francis Sahngun;Lee, Pyung Bok;Park, Soo Young;Kim, Yong Chul;Lee, Sang Chul
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.146-150
    • /
    • 2009
  • Background: A skin temperature difference is one of the variables used in the diagnosis of complex regional pain syndrome. However, there have been no reports as to whether the real (${\Delta}T$) or absolute value ($|{\Delta}T|$) of skin temperature differences should be used in the diagnosis of complex regional pain syndrome. This study was conducted to compare the diagnostic validity of ${\Delta}T$ with $|{\Delta}T|$ for complex regional pain syndrome using receiver operating characteristic curves (ROC). Methods: Infrared thermographic images were obtained from the 144 patients who were suspected to have CRPS in a unilateral limb. After ${\Delta}T$ and $|{\Delta}T|$ calculation from the thermographic image, ROCs of ${\Delta}T$ and $|{\Delta}T|$ were developed, and the areas under the curve (AUC) for the ROC curves were compared. Results: AUCs of ${\Delta}T$ and $|{\Delta}T|$ were 0.520 and 0.746 respectively, this difference was statistically significant (P < 0.001). Conclusions: Absolute skin temperature difference shows greater validity in the diagnosis of CRPS than ${\Delta}T$. Therefore, $|{\Delta}T|$ is more useful when comparing the skin temperature of CRPS patients.

Clinical Risk Evaluation Using Dose Verification Program of Brachytherapy for Cervical Cancer (자궁경부암 근접치료 시 선량 검증 프로그램을 통한 임상적 위험성 평가)

  • Dong‑Jin, Kang;Young‑Joo, Shin;Jin-Kyu, Kang;Jae‑Yong, Jung;Woo-jin, Lee;Tae-Seong, Baek;Boram, Lee
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.553-560
    • /
    • 2022
  • The purpose of this study is to evaluate the clinical risk according to the applicator heterogeneity, mislocation, and tissue heterogeneity correction through a dose verification program during brachytherapy of cervical cancer. We performed image processing with MATLAB on images acquired with CT simulator. The source was modeled and stochiometric calibration and Monte-Carlo algorithm were applied based on dwell time and location to calculate the dose, and the secondary cancer risk was evaluated in the dose verification program. The result calculated by correcting for applicator and tissue heterogeneity showed a maximum dose of about 25% higher. In the bladder, the difference in excess absolute risk according to the heterogeneity correction was not significant. In the rectum, the difference in excess absolute risk was lower than that calculated by correcting applicator and tissue heterogeneity compared to the water-based calculation. In the femur, the water-based calculation result was the lowest, and the result calculated by correcting the applicator and tissue heterogeneity was 10% higher. A maximum of 14% dose difference occurred when the applicator mislocation was 20 mm in the Z-axis. In a future study, it is expected that a system that can independently verify the treatment plan can be developed by automating the interface between the treatment planning system and the dose verification program.

ON THE FINITE DIFFERENCE OPERATOR $l_{N^2}$(u, v)

  • Woo, Gyung-Soo;Lee, Mi-Na;Seo, Tae-Young
    • East Asian mathematical journal
    • /
    • v.16 no.1
    • /
    • pp.97-103
    • /
    • 2000
  • In this work, we consider a finite difference operator $L^2_N$ corresponding to $$Lu:=-(u_{xx}+u_{yy})\;in\;{\Omega},\;u=0\;on\;{\partial}{\Omega}$$, in $S_{h^2,1}$. We derive the relation between the absolute value of the bilinear form $l_{N^2}$(u, v) on $S_{h^2,1}{\times}S_{h^2,1}$ and Sobolev $H^1$ norms.

  • PDF

Autonomous Real-time Relative Navigation for Formation Flying Satellites

  • Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.59-74
    • /
    • 2009
  • Relative navigation system is presented using GPS measurements from a single-channel global positioning system (GPS) simulator. The objective of this study is to provide the real-time inter-satellite relative positions as well as absolute positions for two formation flying satellites in low earth orbit. To improve the navigation performance, the absolute states are estimated using ion-free GRAPHIC (group and phase ionospheric correction) pseudo-ranges and the relative states are determined using double differential carrier-phase data and singled-differential C/A code data based on the extended Kalman filter and the unscented Kalman filter. Furthermore, pseudo-relative dynamic model and modified relative measurement model are developed. This modified EKF method prevents non-linearity of the measurement model from degrading precision by applying linearization about absolute navigation solutions not about the priori estimates. The LAMBDA method also has been used to improve the relative navigation performance by fixing ambiguities to integers for precise relative navigation. The software-based simulation has been performed and the steady state accuracies of 1 m and 6 mm ($1{\sigma}$ of 3-dimensional difference errors) are achieved for the absolute and relative navigation using EKF for a short baseline leader/follower formation. In addition, the navigation performances are compared for the EKF and the UKF for 10 hours simulation, and relative position errors are mm-level for the two filters showing the similar trends.

A Study on Speaker Identification by Difference Sum and Correlation Coefficients of Narrow-band Spectrum (좁은대역 스펙트럼의 차이값과 상관계수에 의한 화자확인 연구)

  • Yang, Byung-Gon;Kang, Sun-Mee
    • Speech Sciences
    • /
    • v.9 no.3
    • /
    • pp.3-16
    • /
    • 2002
  • We examined some problems in speaker identification procedures: transformation of acoustic parameters into auditory scales, invalid measurement values, and comparability of spectral energy values across the frequency range. To resolve those problems, we analyzed the acoustic spectral energy of three Korean numbers produced by ten female students from narrow-band spectrograms at 19 proportional time points of each voiced segment. Then, cells of the first five spectral matrices were averaged to form a matrix model for each speaker. The correlation coefficients and sum of the absolute amplitude difference in each pair of the spectral models of the ten subjects were obtained. Also, some individual matrix models were compared to those of the same subject or the other subject with a similar spectral model. Results showed that in numbers '2' and '9' subjects could not be clearly distinguished from the others but in number '4' it shed some possibility of setting threshold values for speaker identification if we employed the coefficients and the sum of absolute difference. Further studies would be desirable on various combinations of the range of long-term average spectra and the degree of signal pre-emphasis.

  • PDF

Comparison of Model Results for Variation and Resolution of Meteorological Field Using HY-SPLIT (기상장의 종류와 해상도에 따른 HY-SPLIT 모델의 결과 비교)

  • Lee, Chong-Bum;Park, Sang-Jin;Kim, Jea-Chul;Jang, Yun-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.223-230
    • /
    • 2010
  • Trajectory dispersion models are used for the dispersion calculations in air quality assessments, Yellow-sand modeling, environmental planning and the emergency response. Meso-scale forcing and coastal circulations are calculated by trajectory model in the East Asia region. In this study the meteorological fields (GDAS and MM5) coupled to the trajectory model (HY-SPLIT) are applied to simulate the transport and the dispersion. Seoul is selected as a starting point of the HY-SPLIT. The sensitivity studies are performed by conducting an ensemble of simulations using the GDAS and the MM5 model for the same dispersion cases. The results in this study show a significant difference depending on the resolution of meteorological models. Additionally, in most cases of the compared tionally,results from MM5 and GDAS, the absolute and relative distance, shows significant difference and the difference increased with the increasing distance of HY-SPLIT. Therefore, for the case of small domai for twi d field distefbution over complex terrai, should be used only high model temporal or spatial resolution to improve the HY-SPLIT model results.