Measurement and Control of Abnormal Sound for Refrigerator (냉장고의 이상소음에 관한 사례연구)

  • 주재만;김중래;이동현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.380-384
    • /
    • 2001
  • The household reftigerator's noise which is closely related with resident environment can hardly be evaluated its sound quality using the Korean Standards. Radiation characteristics of compressor noise consist of tonal noise in low frequency range and, or narrow band noise in high frequency range. In this study, measuring method for detecting the abnormal and low-level noise in high frequency band is presented, and control method for its reduction is proposed. After installing wall which is similar to living condition, we determined a major concerning frequency band of noise. It can be found the directivity of high frequency noise radiated from compressor by using experiment and analysis. According to isolation of noise transfer path, remarkable noise reduction is achieved.

  • PDF

Root-Cause Investigation of Abnormal Sound from a Heat Exchanger of Condensate Water System in a Nuclear Power Plant (원전 복수계통 열교환기의 이음발생 원인규명)

  • Lee, Jun-Shin;Kim, Tae-Ryong;Lee, Wook-Ryun;Sohn, Seok-Man;Yoon, Seok-Bon;Kim, Man-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1306-1311
    • /
    • 2006
  • The root cause of abnormal sound from a heat exchanger of condensate water system in a nuclear power plant is investigated by using the impact signal-processing methodology based on the Hertz theory. The predicted results for the location of impact force and the loose part size meet good agreement with the identified materials during the overhaul period in the plant. Nuclear power plants have experienced several loose parts and the frequency of the loose part will be increased along the aging of the plants. So, this analysis methodology for the impact signal will be widely utilized for the primary and secondary side of the nuclear power plant.

  • PDF

Abnormal Resonance Noise Phenomenon and Effect through Exhaust Gas Passageway in Urban Combined Power Plant (도심지 복합화력 배가스 통로에서의 이상 소음 현상과 영향)

  • Kim, Yeon-Whan;Lee, Young-Shin;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.866-869
    • /
    • 2004
  • Power transformers, air-intakes and stacks in the urban combined power plant are main noisy sources. Because of Inhabitant complaint by abnormal noise transferred from the power plant. the noise was investigated at power plant and uptown area. The result of diagnosis made the acoustic resonance phenomenon by 580Hz's combustion dynamic pressure with the standing wave mode of sound fields in exhaust passageway of gas turbine into main noise source of public complain. The abnormal noise is caused by the resonance exhaust noise transferred through stacks of power plant.

  • PDF

Improving Stability of Motor Generator Set of the Power Supply System for CEDM in Korean Standard Nuclear Power Plants (한국표준형 원전 제어봉구동장치 전원공급계통의 전동발전기 세트 안정성 개선)

  • Choi, Il Young;Kim, Jin Weon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2016
  • This paper analyzed a root cause of abnormality in the temperature and vibration at generator-side bearing of motor generator set (MG Set), which is a power supply system to control element drive mechanism (CEDM) of nuclear power plants (NPPs), and modified the design of roller-type and sealing method to improve the abnormalities. From the inspection of MG Set and analysis of temperature variation during service, it was found that the abnormal temperature transition was basically associated with original design of generator-side bearing, whose roller was axially restrained by inner race, and that the abnormal vibration level was caused by inserting small chips of cage and V-ring, which were generated due to the abnormal temperature transition at roller bearing. Type of bearing and sealing method were modified based on these analyses. The temperature and vibration level measured at roller bearing showed that the modifications clearly improved the operational stability of MG Set.

Classification of Normal/Abnormal Conditions for Small Reciprocating Compressors using Wavelet Transform and Artificial Neural Network (웨이브렛변환과 인공신경망 기법을 이용한 소형 왕복동 압축기의 상태 분류)

  • Lim, Dong-Soo;An, Jin-Long;Yang, Bo-Suk;An, Byung-Ha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.796-801
    • /
    • 2000
  • The monitoring and diagnostics of the rotating machinery have been received considerable attention for many years. The objectives are to classify the machinery condition and to find out the cause of abnormal condition. This paper describes a signal classification method for diagnosing the rotating machinery using the artificial neural network and the wavelet transform. In order to extract salient features, the wavelet transform are used from primary noise signals. Since the wavelet transform decomposes raw time-waveform signals into two respective parts in the time space and frequency domain, more and better features can be obtained easier than time-waveform analysis. In the training phase for classification, self-organizing feature map(SOFM) and learning vector quantization(LVQ) are applied, and the accuracies of them are compared with each other. This paper is focused on the development of an advanced signal classifier to automatise the vibration signal pattern recognition. This method is verified by small reciprocating compressors, for refrigerator and normal and abnormal conditions are classified with high flexibility and reliability.

  • PDF

Source identification of abnormal noise caused in diesel railcars through spectrum analysis (스펙트럼 분석을 통한 디젤동차 애상소음 원인규명)

  • 이용관;강명석
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.208-217
    • /
    • 1999
  • This paper presents spectrum analysis technique to identify abnormal noise produced in diesel railcars. Coherence and coherent power spectrum are very useful in determining source identifications. Experiments are applied to two different cars with similar phenomena about the case of stop and running condition. Metal contact in mounting bracket part which is excited by excessive transmission vibration is found to cause abnormal noise.

  • PDF

Noise & Vibration Evaluation and Analysis for Propeller Fan System of Air Conditioner Outdoor Unit (에어컨 실외기 프로펠러 홴계의 진동소음 평가 및 해석)

  • Park, Deug-Yong;Mo, Jin-Yong;Lee, Jin-Kyo;Koo, Hyoung-Mo;Choi, Weon-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1405-1409
    • /
    • 2000
  • The electro-magnetic noise generated from fan-driving motor is one of important items in view of abnormal noise which affect the quality of air conditioner noise. The electro-magnetic noise of the outdoor unit is identified by the serial experiments for related parts, whose effects are verified to give proper measures for reduced noise level. The weight of fan appears to be the most important factor, and the stiffness of the frame, such as motor bracket is shown to be important also.

  • PDF

Cause Analysis of abnormal in Low Pressure Turbine Casing in Thermal Power Plant (화력발전소 저압터빈 케이싱 이상진동 원인분석)

  • Koo, Jae Raeyang;Lee, Doo Young;Lee, Wook Ryun;Kim, Hee Soo;Kim, Dong Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.300-302
    • /
    • 2014
  • 발전기 출력의 약 60%을 담당하는 저압터빈의 케이싱은 복수기와 연결되어 있으며 외부케이싱과 내부 케이싱으로 구성되어 있다. 저압터빈 케이싱은 사용연수의 증가에 다른 경년열화로 인하여 터빈 기초 지지대의 침하, 케이싱 볼트의 느슨해짐 등 외부의 여러 가지 환경변화에 의하여 고유진동수가 저하된다. 본고에서는 우리나라 화력발전소 저압터빈 케이싱의 고유진동수 변화에 의하여 터빈 운전 주파수와 일치하는 공진현상이 발생하고 발전설비 운전 신뢰성에 영향을 미치고 있는데 이에 대한 원인 분석과 최소한의 비용으로 공진현상을 저감하고 운전 신뢰성을 확보한 사례에 대하여 기술한다