Root-Cause Investigation of Abnormal Sound from a Heat Exchanger of Condensate Water System in a Nuclear Power Plant

원전 복수계통 열교환기의 이음발생 원인규명

  • 이준신 (한전전력연구원 원자력발전연구소) ;
  • 김태룡 (한전전력연구원 원자력발전연구소) ;
  • 이욱륜 (한전전력연구원 원자력발전연구소) ;
  • 손석만 (한전전력연구원 원자력발전연구소) ;
  • 윤석본 (한수원 울진원자력 제 2 발전소 기계부) ;
  • 김만희 (한수원 울진원자력 제 2 발전소 기계부)
  • Published : 2006.05.01

Abstract

The root cause of abnormal sound from a heat exchanger of condensate water system in a nuclear power plant is investigated by using the impact signal-processing methodology based on the Hertz theory. The predicted results for the location of impact force and the loose part size meet good agreement with the identified materials during the overhaul period in the plant. Nuclear power plants have experienced several loose parts and the frequency of the loose part will be increased along the aging of the plants. So, this analysis methodology for the impact signal will be widely utilized for the primary and secondary side of the nuclear power plant.

Keywords