• Title/Summary/Keyword: ADC Value

Search Result 83, Processing Time 0.057 seconds

The quantitative analysis of Diffusion Weighted Imaging in Breast MRI (유방 MRI 검사에서 확산강조영상의 정량적 분석)

  • Cho, Jae-Hwan;Kim, Hyeon-Ju;Hong, Yin-Sik;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of diffusion weighted images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, diffusion weighted images and ADC map images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The diffusion weighted images showed higher SNR and CNR at the lesion area. In addition, the ADC values were lower at the lesion area.

Diffusion tensor imaging of the C1-C3 dorsal root ganglia and greater occipital nerve for cervicogenic headache

  • Wang, Lang;Shen, Jiang;Das, Sushant;Yang, Hanfeng
    • The Korean Journal of Pain
    • /
    • v.33 no.3
    • /
    • pp.275-283
    • /
    • 2020
  • Background: Previous studies showed neurography and tractography of the greater occipital nerve (GON). The purpose of this study was determining diffusion tensor imaging (DTI) parameters of bilateral GONs and dorsal root ganglia (DRG) in unilateral cervicogenic headache as well as the grading value of DTI for severe headache. The correlation between DTI parameters and clinical characteristics was evaluated. Methods: The fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values in bilateral GONs and cervical DRG (C2 and C3) were measured. Grading values for headache severity was calculated using a receiver operating characteristics curve. The correlation was analyzed with Pearson's coefficient. Results: The FA values of the symptomatic side of GON and cervical DRG (C2 and C3) were significantly lower than that of the asymptomatic side (all the P < 0.001), while the ADC values were significantly higher (P = 0.003, P < 0.001, and P = 0.003, respectively). The FA value of 0.205 in C2 DRG was considered the grading parameter for headache severity with sensitivity of 0.743 and specificity of 0.999 (P < 0.001). A negative correlation and a positive correlation between the FA and ADC value of the GON and headache index (HI; r = -0.420, P = 0.037 and r = 0.531, P = 0.006, respectively) was found. Conclusions: DTI parameters in the symptomatic side of the C2 and C3 DRG and GON were significantly changed. The FA value of the C2 DRG can grade headache severity. DTI parameters of the GON significantly correlated with HI.

Diagnostic Significance of Apparent Diffusion Coefficient Values with Diffusion Weighted MRI in Breast Cancer: a Meta-Analysis

  • Sun, Jiang-Hong;Jiang, Li;Guo, Fei;Zhang, Xiu-Shi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8271-8277
    • /
    • 2014
  • Aims: Apparent diffusion coefficient (ADC) values of nodes in diffusion-weighted imaging (DWI) are widely used in differentiating metastatic from non-metastatic lymph nodes. The purpose of this meta-analysis was to demonstrate whether DWI could contribute to the precise diagnosis of breast cancer (BC) with and without lymph node metastasis (LNM). Materials and Methods: English and Chinese electronic databases were searched for relevant studies followed by a comprehensive literature search. Two reviewers independently assessed the methodological quality of the included trials based on the quality assessment of diagnostic accuracy studies (QUADAS). Summary odds ratios (ORs) and corresponding 95% confidence intervals (95% CIs) were calculated. Results: Final analysis of 624 BC subjects (patients with LNM = 254, patients without LNM = 370) were incorporated into the current meta-analysis from 9 eligible cohort studies. Combined ORs of ADCs suggested that ADC values in BC patients without LNM were higher than in patients with LNM (OR=0.56, 95%CI: 0.11-1.01, p=0.015). Subgroup analysis stratified by country indicated a low ADC value in BC patients with LNM rather than those without LNM among Chinese (OR=1.27, 95%CI: 0.89-1.66, p<0.001), Italians (OR=0.75, 95%CI: 0.13-1.38, p=0.018), and Egyptians (OR=1.27, 95%CI: 0.71-1.84, p<0.001). The findings of subgroup analysis by MRI machine type revealed that ADC values from diffusion MRI may be potential diagnostic indicators for BC using Non-Philips 1.5T (OR=1.10, 95%CI: 0.84-1.36, p<0.001). Conclusions: The main findings of our meta-analysis demonstrated that increased signal intensity on DWI and decreased signals on ADC are helpful in diagnosis of BC patients with or without LNM. DWI could therefore be an important imaging investigation in patients suspected of BC.

A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection (조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI (자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.991-998
    • /
    • 2021
  • The purpose of this study is to investigate the image quality of the SE-EPI and SSH-TSE technique for MR DWI. Datum were analyzed for 35 PACS transmission datum(Normal part: 12 males, 13 females, Cerebral Infarction: 10(5males and 5females), and average age 68±7.32), randomly selected patients who underwent MRDWI tests. The equipment used was Ingenia CX 3.0T, SSH_TSE and SE-EPI pulse sequence and 32 Ch. head coil were used for data acquisition. Image evaluation was performed on the paired t-test and Wilcoxon tests, and was considered significant when the p value was 0.05 or less. As a result of quantitative analysis of SNR for DWI images, the mean and standard deviation values of 4 parts (WM, GM, BG, Cerebellum) in ADC (s/mm2), Diffusion b=0, 1000 images were higher in SE-EPI techniques(ADC: 120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63) than in SSH-TSE techniques(ADC: 99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85)(p<0.05). The CNR values for GM-WM, BG-WM sites were also higher in SE-EPI technique (ADC: 116.08 ± 43.30, b=0:27.23 ± 09.10, b=1000: 78.50 ± 16.56) than in SSH-TSE(ADC: 101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22). As a visual evaluation of observers, ghost artifact, magnetic susceptibility artifacts and overall image quality for SE-TSE and SSH-TSE all yielded high results from SSH-TSE techniques(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). In conclusion, the SE-EPI technique obtained an superiority in SNR and CNR measurements using SSH-TSE, SE-EPI. In the qualitative analysis, the SSH-TSE pulse sequence was obtained a high result according to the pulse sequence characteristics.

Diffusion Weighted Imaging in Musculoskeletal MRI: Analysis on Optimal Number of Excitations Providing better Differentiation of Maglignant Tumor (악성종양의 감별진단을 위한 근골격의 확산강조영상 검사 시 최적의 여기횟수)

  • Choi, Kwan-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.338-344
    • /
    • 2018
  • The purpose of this study was to determine the optimal number of excitations(NEX) of diffusion weighted imaging(DWI) which is clinically useful in patients with musculoskeletal diseases while the scan time is relatively long. In this study, 30 patients underwent knee MRI using diffusion weighted image sequence using b values targeted on the bone and muscle. The NEX were varied from 1 to 5 and the ADC values were measured and analyzed. As a result of the study, 4 NEX and 2 NEX showed an statistically identical effect with the existing NEX on the bone and muscle diffusion weighted images, respectively. Also, it proved that the scan time could be significantly reduced by 21.2 % and 59.6 % compared to the established NEX which meant the optimal NEX could replace the existing NEX. In conclusion, applying the optimal NEX on the musculoskeletal bone and soft tissue DWI could improve the problems caused by the long scan time.

Assessment of solid components of borderline ovarian tumor and stage I carcinoma: added value of combined diffusion- and perfusion-weighted magnetic resonance imaging

  • Kim, See Hyung
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.3
    • /
    • pp.231-240
    • /
    • 2019
  • Background: We sought to determine the value of combining diffusion-weighted (DW) and perfusion-weighted (PW) sequences with a conventional magnetic resonance (MR) sequence to assess solid components of borderline ovarian tumors (BOTs) and stage I carcinomas. Methods: Conventional, DW, and PW sequences in the tumor imaging studies of 70 patients (BOTs, n=38; stage I carcinomas, n=32) who underwent surgery with pathologic correlation were assessed. Two independent radiologists calculated the parameters apparent diffusion coefficient (ADC), $K^{trans}$ (vessel permeability), and $V_e$ (cell density) for the solid components. The distribution on conventional MR sequence and mean, standard deviation, and 95% confidence interval of each DW and PW parameter were calculated. The inter-observer agreement among the two radiologists was assessed. Area under the receiver operating characteristic curve (AUC) and multivariate logistic regression were performed to compare the effectiveness of DW and PW sequences for average values and to characterize the diagnostic performance of combined DW and PW sequences. Results: There were excellent agreements for DW and PW parameters between radiologists. The distributions of ADC, $K^{trans}$, and $V_e$ values were significantly different between BOTs and stage I carcinomas, yielding AUCs of 0.58 and 0.68, 0.78 and 0.82, and 0.70 and 0.72, respectively, with ADC yielding the lowest diagnostic performance. The AUCs of the DW, PW, and combined PW and DW sequences were $0.71{\pm}0.05$, $0.80{\pm}0.05$, and $0.85{\pm}0.05$, respectively. Conclusion: Combining PW and DW sequences to a conventional sequence potentially improves the diagnostic accuracy in the differentiation of BOTs and stage I carcinomas.

Analysis of a Comparability Test between LX Detergent Cleaning Solution and OC Detergent Cleaning Solution Using OC Sensor PLEDIA (OC Sensor PLEDIA를 이용한 LX Detergent Cleaning Solution과 OC Detergent Cleaning Solution의 동등성 평가)

  • Cha, Kyung Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.19-31
    • /
    • 2021
  • This study aimed at comparing the performance of imported LX detergent cleaning solution (LX-CS) and the self-manufactured OC cleaning solution (OC-CS), based on functional and quantitative analysis. The functional analysis was carried out using apparent diffusion coefficient (ADC) values. For quantitative analysis, precision, linearity, and carry-over rates were measured with commercial control materials according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Using OC-Sensor PLEDIA (Eiken Chemical, Japan), the ADC value of all cuvettes satisfied the acceptance criteria. For quantitative analysis, precision was less than 5.0% for the two products, and carry-over rates were less than ±1.00%. The linearity slopes and r2 values were 1.0017 and 0.9982 in the LX-CS, and 0.9924 and 0.9996 in the OC-CS, respectively. The correlation coefficient (r) was found to be 0.9997. Also, the percent difference in correlation with 40 artificial-stool specimens was less than 10% and the p-value was less than 0.1. The result of standard deviation ratio (D: ±1 SD ratio) was similar for both products. In conclusion, the functional and quantitative analyses of the two products were compared and showed similar results. In the future, the self-manufactured OC-CS will be able to provide a much more stable and faster supply than the imported LX-CS.

Prediction of Axillary Lymph Node Metastasis in Early Breast Cancer Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging and Diffusion-Weighted Imaging

  • Jeong, Eun Ha;Choi, Eun Jung;Choi, Hyemi;Park, Eun Hae;Song, Ji Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.125-135
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI), and diffusion-weighted imaging (DWI) variables, for axillary lymph node (ALN) metastasis in the early stage of breast cancer. Materials and Methods: January 2011-April 2015, 787 patients with early stage of breast cancer were retrospectively reviewed. Only cases of invasive ductal carcinoma, were included in the patient population. Among them, 240 patients who underwent 3.0-T DCE-MRI, including DWI with b value 0 and $800s/mm^2$ were enrolled. MRI variables (adjacent vessel sign, whole-breast vascularity, initial enhancement pattern, quantitative kinetic parameters, signal enhancement ratio (SER), tumor apparent diffusion coefficient (ADC), peritumoral ADC, and peritumor-tumor ADC ratio) clinico-pathologic variables (age, T stage, multifocality, extensive intraductal carcinoma component (EIC), estrogen receptor, progesterone receptor, HER-2 status, Ki-67, molecular subtype, histologic grade, and nuclear grade) were compared between patients with axillary lymph node metastasis and those with no lymph node metastasis. Multivariate regression analysis was performed, to determine independent variables associated with ALN metastasis, and the area under the receiver operating characteristic curve (AUC), for predicting ALN metastasis was analyzed, for those variables. Results: On breast MRI, moderate or prominent ipsilateral whole-breast vascularity (moderate, odds ratio [OR] 3.45, 95% confidence interval [CI] 1.28-9.51 vs. prominent, OR = 15.59, 95% CI 2.52-96.46), SER (OR = 1.68, 95% CI 1.09-2.59), and peritumor-tumor ADC ratio (OR = 6.77, 95% CI 2.41-18.99), were independently associated with ALN metastasis. Among clinico-pathologic variables, HER-2 positivity was independently associated, with ALN metastasis (OR = 23.71, 95% CI 10.50-53.54). The AUC for combining selected MRI variables and clinico-pathologic variables, was higher than that of clinico-pathologic variables (P < 0.05). Conclusion: SER, moderate or prominent increased whole breast vascularity, and peritumor-tumor ADC ratio on breast MRI, are valuable in predicting ALN metastasis, in patients with early stage of breast cancer.

Added Value of Diffusion Weighted Imaging for Detecting Pancreatic Abnormality in Patients with Clinically Suspected Acute Pancreatitis

  • Nam, In Chul;Kim, Seung Ho;Kim, Seon-Jeong;Lim, Yun-jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • Purpose: To evaluate the added value of diffusion weighted imaging (DWI) to computed tomography (CT) for detecting pancreatic abnormality in patients with clinically suspected acute pancreatitis (AP). Materials and Methods: 203 patients who underwent abdomen CT and subsequent DWI to do a workup for epigastric pain were analyzed. Two blinded radiologists independently performed an interval reading based on CT image sets first, then based on combined CT and DWI image sets. The diagnostic criterion on DWI was the increased signal intensity in the pancreas to that of the spleen. For quantitative analysis, the third radiologist measured ADC value of the pancreas in each patient. Results: For AP (n = 43), the sensitivity for detecting pancreatic abnormality increased, from 42% to 70% for reader 1 (P < 0.05) and from 44% to 72% for reader 2 (P < 0.05). For borderline pancreatitis (n = 42), the sensitivity also increased, from 10% to 26% for reader 1 (P < 0.05) and from 7% to 29% for reader 2 (P < 0.05). The mean ADC values (unit, ${\times}10^{-3}mm^2/s$) were significantly different among the three groups (for AP, $1.09{\pm}0.16$; for borderline pancreatitis, $1.28{\pm}0.2$; for control, $1.46{\pm}0.15$, P < 0.05). Conclusion: Sensitivity for detecting pancreatic abnormality increased significantly after adding DWI to CT in patients with clinically suspected AP.