• Title/Summary/Keyword: AC7A

Search Result 878, Processing Time 0.03 seconds

Electrical Properties of Conducting Blends for AC & DC (전도성 블랜드의 AC와 DC에 대한 전기적 특성)

  • Lee, Tae-Hee;Kim, Jong-Eun;Kim, Yun-Sang;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1481-1483
    • /
    • 2003
  • Molecular motions of polyaniline conducting blends were prepared. Surface resistance of its blends was investigated by a Surface Resistance Meter. DC electrical properties were investigated by Thermally Stimulated Currents(TSC) method and AC dielectric properties were investigated by Dielectric Thermal Analyzer (DETA) in the temperature range from $-50^{\circ}C$ to $120^{\circ}C$ at 1E0 Hz $^{\sim}$ 1E7 Hz for a comparative study of molecular relaxation. Using Scanning Electron Microscopy(SEM), relations of both microstructure and conduction behaviors was observed.

  • PDF

Operation of NMOSFET-only Scan Driver IC for AC PDP (NMOSFET으로 구성된 AC PDP 스캔 구동 집적회로의 동작)

  • 김석일;정주영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.7
    • /
    • pp.474-480
    • /
    • 2003
  • We designed and tested a new scan driver output stage. Compared to conventional CMOS structured scan driver IC′s, the new NMOSFET-only scan driver circuit can reduce the chip area and therefore, the chip cost considerably. We confirmed the circuit operation with open drain power NMOSFET IC′s by driving 2"PDP test panel. We defined critical device parameters and their optimization methods lot the best circuit performance.

A novel in-situ vacuu encapsulted lateral field emitter triode (자체적으로 진공을 갖는 수평형 전계 방출 트라이오드)

  • 임무섭;박철민;한민구;최연익
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.12
    • /
    • pp.65-71
    • /
    • 1996
  • A novel lateral field emitter triode has been designed and fabricated. It has self-vacuum environmets and low turn-on voltage, so that the chief problems of previous field emission devices such as additional vacuum sealing process and high turn-on voltage are settled. An in-situ vaccum encapsulation empolying recessed cavities by isotropic RIE (reactive ion etch) method and an electron beam evaporated molybdenum vacuum seals are implemented to fabricate the new field emitter triode. The device exhibits low turn-on voltage of 7V, stabel current density of 2.mu.A/tip at V$_{AC}$ = 30V, and high transconductance (g$_{m}$) of 1.7$\mu$S at V$_{AC}$ = 22V. The superb device characteristics are probably due to sub-micron dimension device structure and the pencil type lateral cathode tip employing upper and lower LOCOS oxidation.

  • PDF

Kinetics and Mechanism of the Pyridinolysis of Dimethyl Isothiocyanophosphate in Acetonitrile

  • Adhikary, Keshab Kumar;Lee, Hai-Whang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2260-2264
    • /
    • 2012
  • The kinetics and mechanism of the pyridinolysis ($XC_5H_4N$) of dimethyl isothiocyanophosphate are investigated in acetonitrile at $55.0^{\circ}C$. The Hammett and Br$\ddot{o}$nsted plots for substituent X variations in the nucleophiles exhibit two discrete slopes with a break region between X = 3-Ac and 4-Ac. These are interpreted to indicate a mechanistic change at the break region from a concerted to a stepwise mechanism with a rate-limiting expulsion of the isothiocyanate leaving group from the intermediate. The relatively large ${\beta}x$ values imply much greater fraction of frontside nucleophilic attack TSf than that of backside attack TSb. The steric effects of the two ligands play an important role to determine the pyridinolysis rates of isothiocyanophosphates.

Mass Production of a Recombinant Baculovirus Expressing CpBV-ELP1 and Control of the Beet Armyworm, Spodoptera exigua (CpBV-ELP1 발현 재조합 벡큘로바이러스의 대량 증식과 파밤나방 방제 기술)

  • Park, Arum;Kim, Yonggyun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.279-286
    • /
    • 2015
  • Cotesia plutellae bracovirus (CpBV) is a polydnavirus symbiotic to C. plutellae parasitizing young larvae of the diamondback moth, Plutella xylostella. Several CpBV genes play important roles in suppressing immune responses of the parasitized larvae. This study tested a hypothesis that the CpBV genes inducing host immunosuppression could be applied to develop a potent recombinant baculovirus. Based on a previous study, a recombinant baculovirus expressing CpBV-ELP1 (AcMNPV-ELP1) was selected and multiplied using larvae of the beet armyworm, Spodoptera exigua. The recombinant viruses were produced in a yield of $5{\times}10^{10}$ polyhedral inclusion body (PIB)/larva. The cultured AcMNPV-ELP1 exhibited a much higher pathogenicity against S. exigua larvae. However, its insecticidal activity was varied among larval instars of S. exigua, in which first and late instars were high susceptible. Spray of the recombinant baculovirus ($5{\times}10^6PIB/mL$) exhibited higher control efficacy (${\approx}$ 88%) against S. exigua larvae infesting cabbage than a chemical insecticide, tebufenozide, at 7 days after treatment. These results indicate that AcMNPV-ELP1 mass-cultured using host insect system is highly pathogenic and can be applied to develop a novel microbial control agent.

Efficient RBAC based on Block Chain for Entities in Smart Factory (스마트 팩토리 엔터티를 위한 블록체인 기반의 효율적인 역할기반 접근제어)

  • Lee, YongJoo;Lee, Sang-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.69-75
    • /
    • 2018
  • The key technology of Industry 4.0, Smart factory is evaluated as the driving force of our economic development hereafter and a lot of researches have been established. Various entities including devices, products and managers exist in smart factory, but roles of these entities may be continuous or variable and can become extinct not long after. Existing methods for access control are not suitable to adapt to the variable environment. If we don't consider certain security level, important industrial data can be the targets of attacks. We need a new access control method satisfying desired level of efficiency and security without excessive system loads. In this paper, we propose a new RBAC-PAC which extend AC defined for PKC to the authority attribute of roles. We distribute PACs for roles through block chain method to provide the efficient access control. We verified that RBAC-PAC is more efficient in the smart factory with large number of entities which need a frequent permission update.

A Regeneration Inverter for Traction Applications with a Active Power Filter (능동전력필터를 가진 지하철 회생인버터 시스템)

  • Won, Chung-Yuen;Jang, Su-Jin;Kim, Yuen-Chung;Lee, Byoung-Kuk;Bae, Chang-Hwan;Kim, Yong-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.25-32
    • /
    • 2006
  • This paper proposes a regeneration inverter system, which can regenerate the excessive power form do bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are included to ac current source. The regeneration inverter is operated as two modes. In the regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and in the active power filter mode, it can compensate harmonic distortion produced by the rectifier substation. In this paper, the regeneration inverter uses PWM DC/AC inverter algorithm and the active power filter uses p-q theory. From the informative simulation and experimental results, which are performed wiith a prototype rated 3.7[kw], it can expected that the proposed system can be effectively applied in the real traction system rated 100[kw].

The Characteristics on Transport Current of Bi-2223 Based Prototype HTS Cable (Bi-2223계 Prototype 고온 초존도 케이블의 전류 통전 특성)

  • 김영석;이병성;곽민환;장현만;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.630-635
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-T$\sub$2/ superconductor(HTS). Thus we investigated previously the electrical and mechanical characteristics on Bi-2223 Ag sheathed tape. And a prototype HTS cable have been designed constructed and tested. In case of 19-filament type transport losses agree with the results of norris theory(strip). The critical current of HTS cable(1, 19-filament) in LN$_2$was 116[A], 240[A] and degradation coefficient(k) was 0.71, 0.73 respectively. In case of 19-filament cable critical current was decreased because of mechanical strain at pitch. And AC loss of HTS cable(19-filament) was 0.7 [W/m] in 240[A] loading

  • PDF

Reliability Analysis of AC Railway Substation by using FTA (FTA를 이용한 교류전철변전소의 신뢰도 분석)

  • Ku, Bon-Hui;Cha, Jun-Min;Kim, Hyung-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.248-254
    • /
    • 2008
  • Electric railway system consists of traction power system, rolling stock, track, and overhead line system. A railway substation transforms the electric power transmitted from a electric power company and supply it to the railway power system for the operation of traction system.. It is very important to prevent a possible accident and keep the security of electric power system. This paper proposes a reliability analysis of AC railway substation by using Fault Tree Analysis(FTA). Failure rates of each equipment of railway substation are used to evaluate the reliability of railway substation. The analyzed results can be used to improve the system reliability. FTA is performed by the commercialized program of Relex(Ver. 7.7).

  • PDF

A Study on the Harmonics Measurement and Assessment of the Electrolyzer Loads (전해조 부하의 고조파 측정 및 평가에 관한 연구)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Park, Sang-Young;Lee, Il-Moo;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.29-37
    • /
    • 2006
  • Heavy chemical industries have nonlinear loads including elecrolyzers. AC-DC converters are the most widely used in an elecrolysis in a chemical plant. The electrolysis consists of AC-DC converter groups connected in parallel at the DC side. The converter operations cause harmonic currents and create distortions on the sinusoidal voltage of the AC power system. This paper provides an in depth analysis on harmonics field measurement for the electrolyzer loads and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE 519-1992.