새로운 유지구동전압 반감형 AC PDP 구동회로 (A New Sustaining Driver for AC PDPs with Reduced Sustain Voltage by Half)

  • 임승범;조필용;채수용;강경우;유종걸;고종선;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.452-455
    • /
    • 2005
  • This paper proposes a new sustaining driver for AC PDP(Plasma Display Panel), which improves the performance of conventional circuit with reduced sustain voltage such as TERES(TEchnology of REciprocal Sustainer). In the TERES circuit, the sustain voltage is the half of general sustaining driver and there is no energy recovery circuit. The circuit proposed in his paper has an energy recovery circuit and removes surge currents. Although the energy recovery circuit is added, the number of active switching elements is the same as the TERES circuit. The operations of the proposed circuit are analyzed for each mode and its validity is verified by the simulations using PSpice program.

  • PDF

Micro-discharged plasma density, electron temperature and excited xenon density for enhancement of vacuum ultraviolet luminous efficiency in alternating current plasma display panel

  • Choi, Eun-Ha;Oh, Phil-Yong;Seo, Yoon-Ho;Cho, Guang-Sup;Uhm, Han-S
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.161-166
    • /
    • 2005
  • The plasma ion density in AC-PDP has shown to be increased from $5.6{\times}10^{11}cm^{-3}$ to $9.0{\times}10^{11)cm^{-3}$ as the Xe mixture ratio to neon increase from 1 % to 10 %, respectively, at fixed pressure of 400 Torr, by using the micro-Langmuir probe. It is noted that the plasma ion density is density increases as the gas pressure increases in this experiment. The electron temperature decreases from 2.3 to 1.2 eV as the Xe mole fraction increases from 1 % to 10 % at fixed pressure of 400 Torr, which is measured by the micro Langmuir probe and high-speed ICCD camera in this experiment. It is noted that the electron temperature decreases as the gas pressure increases from 150 to 400 Torr in this experiment. It is also observed that the exited Xe atom density and the plasma ion density are in strong correlation sharp between each other in this experiment. It is noted that $5.2{\times}10^{12}cm^{-3}$ in the $1s_5$ metastable state and $1.2{\times}10^{12}cm^{-3}$ in the $1s_4$ resonance state for the PDP cell with gap of 50 um distances under the fixed gas pressure of 400 Torr and Xe content ratio of 10 %.

  • PDF

The Effect of Dielectric Thickness and Barrier Rib Height on Addressing Time of Coplanar ac PDP

  • Lee, Sung-Hyun;Kim, Young-Dae;Shin, Joong-Hong;Cho, Jung-Soo;Park, Chung-Hoo
    • Journal of KIEE
    • /
    • 제11권1호
    • /
    • pp.41-45
    • /
    • 2001
  • The addressing time should be reduced by modifying cell structure and/or driving method in order to replace the dual scan system by single scan and increase the luminance in large ac plasma display panel(PDP). In this paper, the effects of the dielectric layer thickness and the barrier rib height on the addressing time of ac PDP are investigated. It is found out that the addressing time was decreased with decreasing thickness of dielectric layer on the front glass and thickness of white dielectric layer on the rear glass. The decreasing rate were 160ns/10${\mu}{\textrm}{m}$ and 270nsd/10${\mu}{\textrm}{m}$, respectively. Also in case of decreasing the height of barrier rib, addressing time was decreased at the rate of 550ns/10${\mu}m$.

  • PDF

교류형 플라즈마 표시키의 발광 효율 개설을 위한 실 구조의 방전 특성 분석 (Analysis on the Discharge Characteristics of New Cell Structure for Luminous Efficacy Improvement in an AC Plasma Display Panel)

  • 배현숙;황기웅
    • 조명전기설비학회논문지
    • /
    • 제22권6호
    • /
    • pp.7-13
    • /
    • 2008
  • 본 논문은 수치 해석을 이용한 교류형 플라즈마 표시기의 발광 효율 개선에 대한 연구를 주 내용으로 하고 있으며, 긴 전극 간격을 가지는 유지 전극들 사이에 2개의 보조 전극을 삽입한 5전극 신 구조에서의 방전 특성에 대해 분석하였다. 2차원의 수치 해석 결과에 의하면 어드레스 전극에 보조 펄스가 인가되는 구동 파형을 적용했을 때, 신 구조는 일반적인 3전극 면방전 구조에 비해 대략 52[%]의 효율 증가를 보였다. 결과적으로 방전 초기에 보조 전극 사이에서 일어나는 방전의 크기는 축소되고 주방전에 해당하는 유지 전극 사이의 긴 간격에서의 방전은 확장될수록 플라즈마 표시기의 유지 방전에 있어서 VU V생성 효율의 개선 효과는 커진다고 볼 수 있다. 이와 같은 수치 해석 결과에 대한 신뢰성은 실험 결과를 제시함으로써 검증할 수 있다.

Long Electrode Gap을 가진 Macro Cell에서의 고효율 PDP 특성 연구 (High Efficacy Plasma Display Utilizing Macro Discharge Cell Structure with Long Electrodes Gap)

  • 김민태;허준;김윤기;김동현;이해준;이호준
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1314-1318
    • /
    • 2012
  • Recently, applications of plasma display to the large public display and transparent display gain much attention. With this background, we report characteristics of opposite electrodes discharge cell with long electrode gap in comparison with conventional co-planar surface discharge. The cell size of test panel is $2950{\mu}m{\times}840{\mu}m$, which corresponds to that of the display having diagonal size of 130" with XGA resolution. Electrode gap of co-planar and opposite electrode structure are $240{\mu}m$ and $500{\mu}m$ respectively. These gap dimensions provide similar driving voltage windows. Experimental results show that opposite discharge provides approximately four fold higher luminous efficacy compared with that of the surface discharge. Resulting efficacy is found to be higher than 19 lm/W in green phosphor with 10 KHz continuous pulse operation.

산소 이온 빔 보조 증착된 AC PDP용 MgO 보호막의 특성 연구 (Structural and Discharge Characteristics of MgO Deposited by Oxygen-Ion-Beam-Assisted Deposition in AC PDP)

  • 이조휘;김광호;안민형;홍성재;임승혁;권상직
    • 한국진공학회지
    • /
    • 제16권5호
    • /
    • pp.338-342
    • /
    • 2007
  • MgO는 플라즈마 디스플레이 패널 (Plasma Display Panel, PDP)의 보호막으로 널리 쓰이고 있다. 본 실험에서는 산소 이온 빔을 이용하여 증착된 MgO 보호막의 특성을 조사하였다. MgO 증착 시 보조 산소 이온 빔의 에너지를 변화시킴에 따라 MgO 보호막의 특성과 PDP 패널 발광특성에 미치는 영향을 분석하였다. 본 연구에서는 산소 이온 에너지가 300 eV 일 때 소자의 방전개시전압이 가장 낮게 나타났고, 발광 휘도 및 발광 효율은 가장 높게 나타났다. 또한 산소 이온 빔의 조사에너지에 따라 MgO 박막의 결정성 및 표면조도가 크게 영향을 받는 것을 확인할 수 있었다. 산소 이온 빔 보조 증착 방법을 이용하여 패널의 발광 휘도와 발광 효율 등 발광특성을 개선하였다.

AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법 (A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP)

  • 조병권
    • 전자공학회논문지
    • /
    • 제51권2호
    • /
    • pp.168-172
    • /
    • 2014
  • 교류형 플라즈마 디스플레이에서 유지기간 중에 자기소거 방전을 발생시켜서 휘도효율을 향상시키기 위한 새로운 유지 구동방법이 제안된다. 일반적인 AC PDP에서 하나의 서브필드 시간은 초기화, 기입, 유지기간으로 나누어져 있다. 그 중 유지기간 동안에 2개의 상판 전극인 X와 Y 전극에 교대로 사각 유지파형이 인가되어 화상을 표시하기 위한 유지기간 중의 플라즈마 방전이 연속적으로 발생된다. 그러나 일반적인 구동방법에 있어서 하판의 A전극에는 기입기간에서 종래의 구동방법에서는 셀을 선택할 때만 기입파형이 구동되고 유지기간 중에는 접지 상태로 놓여있으므로 유지 방전에 관여하지 않는다. 본 실험에서는 유지기간 중에 자기소거 방전을 발생시켜 휘도효율을 상승시키기 위하여 유지펄스의 뒷부분에서 음의 펄스를 A전극에 인가하였다. A전극의 음의 펄스는 주 유지방전이 발생된 후 셀 내부의 공간전하들을 벽전하로 전환시켜서 3전극의 전위가 접지 상태가 될 때 재 축적된 벽전하로 인하여 방전을 한번 더 유도시켰다. 그 결과, 유지기간 중 A 전극의 전압 높이에 따른 휘도 효율을 측정하였고 최적의 구동전압을 적용했을 때 휘도효율을 측정한 결과 종래와 비교해서 약 40 % 향상되었다.

PLD를 사용한 PDP용 구동실험장치의 개발 (Development of the Experimental Driving System with PLD for PDPs)

  • 손현성;임찬호;염정덕
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.48-54
    • /
    • 2004
  • 플라즈마 디스플레이 패널의 구동실험을 용이하게 할 수 있는 구동실험장치를 개발하였다. 이 장치는 펄스의 타이밍을 컴퓨터상에서 설계하고 시뮬레이션 할 수 있고 이렇게 설계된 타이밍을 사용하여 PLD에 프로그래밍하고 고전압 FET 스위치들을 제어할 수 있다. 이 장치는 기존의 로직 gate IC를 이용하여 하드웨어적으로 스위칭 로직을 구현하는 것 보다 펄스로직의 설계시간을 단축시킬 수 있으며 구동방식의 변경에 따른 펄스의 타이밍 변경도 용이하다. 이 구동장치를 가지고 상용화 되어있는 ADS 구동방식을 구현하여 3전극 AC PDP의 계조구현 실험을 하였다.

Integrated DC-DC Converter Based Energy Recovery Sustainer Circuit for AC-PDP

  • Park, Jae-Sung;Shin, Yong-Saeng;Hong, Sung-Soo;Han, Sang-Kyoo;Roh, Chung-Wook
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.878-885
    • /
    • 2012
  • A new sustainer with primary-side integration of DC/DC converters and energy recovery(SPIDER) circuits is proposed. The proposed circuit operates as a DC-DC converter during address period and energy recovery circuit during sustain period. Therefore, the conventional three electronic circuits composed of the power supply, X-driver, and Y-driver can be reduced to one circuit. As a result, it has desirable advantages such as a simple structure, less mass, fewer devices and cost reduction. Moreover, since the Zero Voltage Switching (ZVS) of all power switches can be guaranteed, a switching loss can be considerably decreased. To confirm the operation, validity, and features of the proposed circuit, experimental results from a prototype for 42-inch PDP are presented.

AC PDP의 Ramp 파형 개선에 따른 Contrast ratio 향상에 관한 연구 (Ramp Waveform Generating Circuit for Improving the Contrast Ratio in AC Plasma Display Panel)

  • 이성현;김동현;김영기;허정은;신중홍;이호준;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1588-1590
    • /
    • 2001
  • The voltage controlled ramp waveform(VCR) has recently been used in the reset period prior to addressing for plasma display. However, in this paper, the current controlled ramp waveform(CCR) which may prevent the oscillation of gap voltage cause current growth and decrease the background luminance has been suggested. As a result, in case of CCR method, the contrast ratio was about 14% increased compared with VCR method, whereas the addressing and sustainin discharge characteristics of CCR method were same with those of VCR method.

  • PDF