열수축형을 이용한 XLPE케이블 종단부의 전기적 특성 (Electrical Properties of XLPE Cable Termination using Thermal Contraction Type)

  • 백승명;최재형;최진욱;김상현;김영석;김선구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.395-396
    • /
    • 2009
  • For investigation of electrical properties of XLPE cable termination, we prepared a thermal contraction type kit and 6.6kV XLPE cable. The cable termination that have simulated defect by badness construction have been manufactured and their insulation characteristics such as ac and impulse withstand test have been measured. The influence of defects such as thickness decrease and heating time have been studied. When thickness decreased 1mm, the decreased of AC breakdown voltage value is not very distinctive. However, when thickness decreased 2mm, the insulation AC breakdown voltage value was very low down to 43kV. When approved heat for 300s than 60s, AC Breakdown voltage value appeared high. And also, after insulation breakdown took place, the sample was observed before and after disassembly, and the insulation breakdown hole was observed by means of optical microscope.

  • PDF

고압 적층 칩 캐패시터의 유전체 두께 및 내부전극 형상에 따른 AC, DC 절연 파괴 특성 (The AC, DC Dielectric Breakdown Characteristics according to Dielectric Thickness and Inner Electrode Pattern of High Voltage Multilayer Ceramic Capacitor)

  • 윤중락;김민기;이석원
    • 한국전기전자재료학회논문지
    • /
    • 제21권12호
    • /
    • pp.1118-1123
    • /
    • 2008
  • High voltage multilayer ceramic capacitors (MLCCs) are classified into two classes-those for temperature compensation (class I) and high dielectric constant materials (class II). We manufactured high voltage MLCC with temperature coefficient characteristics of C0G and X7R and studied the characteristics of electric properties. Also we studied the characteristics of dielectric breakdown voltage (V) as the variation of thickness in the green sheet and how to pattern the internal electrodes. The dielectric breakdown by electric field was caused by defects in the dielectric materials and dielectric/electrode interface, so the dielectric thickness increased, the withstanding voltage per unit (E) thickness decreased. To overcome this problem, we selected the special design like as floating electrode and this design affected the increasing breakdown voltage(V) and realized the constant withstanding voltage per unit thickness(E). From these results, high voltage application of MLCCs can be expanded and the rated voltage can also be develop.

모의 GIS 내에서 파티클의 재질에 따른 절연파괴 특성 (The Breakdown Characteristics due to Particles in GIS Chamber)

  • 이재걸;곽희로;이강수;김경화;조국희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1997년도 추계학술발표회논문집
    • /
    • pp.67-69
    • /
    • 1997
  • Abstract - In this paper, the behaviour and effect of various particles made of conducting wires( Fe, Cu, Al ) in a SF6 insulated electrode system, are presented. It is shown that the ac breakdown voltage of compressed SF6 is influenced by different conducting particles. The breakdown voltage due to the particle is dependent of a class of particle. The breakdown voltage due to Cu particle was the highest and the breakdown voltage due to Al particle was the lowest.

  • PDF

침전극 곡률 반경에 따른 절연유의 절연파괴 특성 (Breakdown Characteristic of Transformer Oil Depending on Tip Radius)

  • 이종섭;정수현;이흥규;임기조;김현후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1478-1480
    • /
    • 1997
  • We investigated the breakdown characteristic of mineral oil according to applied voltage and tip radius. In this experiment, electrode system was point-plane geometry. The tip radius of needle was 5, 10, 20 and $25{\mu}m$, respectively. Applied voltage was AC and DC. We measured breakdown voltage for each tip radius with increasing electrode gap, 2mm to 10mm. Under nonuniform electric field, breakdown strength was higher when needle was negative than when needle was positive. Because it is polarity effects due to space charge. And the more sharp tip radius, whether we applied AC or DC, the higher breakdown strength. As tip radius increase, breakdown strength decreases exponentially.

  • PDF

고온초전도 한류기의 절연설계를 위한 과냉각 액체질소의 절연내력 특성 (Dielectric Characteristics of Subcooled $LN_2$ for Insulation Design of HTS Fault Current Limiters)

  • 백승명;정종만;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.46-50
    • /
    • 2003
  • In the dielectric insulation design of any high temperature superconducting (HTS) apparatus as well as HTS fault current limiter in the electrical power systems, the breakdown characteristics of cryogenic coolants such as liquid nitrogen ($LN_2$) are an important factor of the insulating engineering. Previous reports concerned with the breakdown characteristics of liquid nitrogen have pointed out that bubbles and gaseous nitrogen have a treat influence on their breakdown phenomena, However, useful data for practical insulation design of HTS fault CUITent limiter operating at subcooled L$N_2$ have not been obtained enough. Therefore, this paper presents an experimental investigate of breakdown phenomena in liquid nitrogen under AC voltage, And, we observed the breakdown voltage (BDV) of liquid nitrogen with lowering temperature. The Weibull plots of the breakdown voltage of subcooled $LN_2$ for the needle-plane electrode with d= 10 mm are studied, The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated, The relationship between the AC breakdown characteristics and the temperature were clarified.

170[kV] GIB 내에서 건조공기(Dry Air)의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 170[kV] GIB)

  • 한기선;윤진열;주형준
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.136-142
    • /
    • 2010
  • In this paper, we changed $SF_6$ insulation gases used already in the GIB(Gas Insulated Bus, gas insulated busbar) of switching appliances of power grid 170[kV] GIS(Gas Insulated Switchgear, Gas Insulated Switchgear) with green insulation dry air gases and studied dielectric breakdown voltage characteristics by the AC voltage withstand test. Withstand test AC voltage applied to the standard KEPCO's 170[kV] GIB with dry air insulation and and the equivalent of dry air and $SF_6$ gas were examined. Breakdown voltage of dry air, using an expression of the experiments were calculated and AC Withstand criterion of dry air insulation for the AC voltage test was derived. Using the criterion, dry air gases can be used instead of the $SF_6$ gas was confirmed in the factory acceptance test at 170[kV] GIB.

고압전동기 고정자 권선에서 비파괴와 파괴시험의 비교 (Comparison of Nondestructive and Destructive Tests in High Voltage Motor Stator Windings)

  • 주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2097-2100
    • /
    • 1999
  • Nondestructive and destructive tests were performed the stator windings of three high voltage motors prior to the rewind. Nondestructive tests included ac current increase rate($\Delta$I), dissipation factor(${\Delta}tan{\delta}$), and maximum partial discharge(Qm) The destructive tests included breakdown at three phases with ac voltage. Flashover occurred between the connected winding of endwinding and the stator flame. In two cases creeping discharge occurred between the individual phase windings and the wedges In the stator ends. The results of destructive tests could rarely be determined the breakdown voltage.

  • PDF

에폭시/고무 거시계면에서 장시간 절연파괴전압에 대한 연구 (Study on the Long Time Breakdown Voltage in the Macro Interface between Epoxy and Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.1003-1008
    • /
    • 2002
  • In this paper, the estimation of lifetime with the various conditions of the interface between toughened epoxy and rubber which are consisting materials of underground power delivery system has been studied. After the measurement of the short time AC interfacial breakdown strength on macro interfaces at room temperature, the breakdown time at several voltages were measured under the constant voltages lower than the short time breakdown voltage. The long time breakdown voltage was calculated by using Inverse Power Law. Two types of interfaces was studied. One was the interface between toughened epoxy and EPDM(Ethylene Prorylene Diene Terpolymer). The other was the interface between toughened epoxy and silicon rubber. Interfacial pressure and roughness of interfaces was determined through the characteristic of short time AC interfacial breakdown strength. Oil condition was no oiled, low viscosity oiled and high viscosity oiled. High viscosity oiled interface between Toughened epoxy and silicon rubber had the best lifetime exponent, 20.69. and the breakdown voltage of this interface after 30 years was evaluated 19.27㎸.

불평등 전계에서 $SF_6/N_2$의 초고압 AC전압 절연내력 시뮬레이션

  • 허창수;이병택;최순호;심명섭;안정식;황청호;장용무
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.37-37
    • /
    • 2010
  • In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. In this paper, breakdown experiment values and breakdown simulation value are compared. Streamer theory was used for predicting breakdown voltage. For accurate simulation, this simulation apply utilization factor using CST program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. But with gap lengths increasing, the breakdown voltage is saturated. So simulation need surface roughness factor.

  • PDF

저항형 고온초전도 한류기용 절연체의 절연 특성 (Breakdown Characteristics of Insulators for a Resistor Type HTS Fault Current Limiter)

  • 백승명;류엔반둥;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.48-52
    • /
    • 2004
  • Breakdown characteristics of insulator-liquid nitrogen ($LN_2$) composite insulation for resistor type High $T_c$/ superconducting fault current limiter (HTSFCL) under ac and impulse voltage in $LN_2$ has been studied using model electrode systems. Electrodes for model electrode systems were made of SUS 304 contacted fiberglass reinforced plastic (FRP) and Au coated sapphire. The breakdown characteristics of model electrode systems were investigated experimentally for FRP thickness ranging from 1 mm to 5 mm. surface distance ranging from 2.5 mm to 7 mm and electrode gap ranging from 1 to 5 mm. The experimental data suggested that the breakdown voltage of model electrode systems in $LN_2$ is highly dependent on the surface distance, electrode gap as well as on the FRP thickness. Also, we had observed discharge traces and puncture due to high-voltage 60-Hz AC stress.