• Title/Summary/Keyword: A-PDA

Search Result 1,756, Processing Time 0.028 seconds

Remote Devices Data Monitoring System based on Wireless PDA (무선 PDA 기반의 원격 장치 데이터 모니터링 시스템)

  • Seo, Jung-Hee;Kim, Kil-Young;Park, Hung-Bog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.611-614
    • /
    • 2007
  • This paper suggests a TCP/IP-based remote data monitoring system, which combines PDA (Personal Digital Assistant) and WLAN (Wireless Local Area Network) technologies. Wireless PDA devices are used for remote monitoring of wireless communication by continuously collecting remote device data transmitted from servers such as temperature, humidity and device status, and displaying them on mobile devices. Therefore, remote data monitoring systems that integrate wireless and wired services provide data collection adaptive to administrators and efficient identification of device status.

  • PDF

Shear-induced color transition of PDA (polydiacetylene) liposome in polymeric solutions

  • Lee, Sung-Sik;Chae, Eun-Hyuk;Ahn, Dong-June;Ahn, Kyung-Hyun;Yeo, Jong-Kee
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.1
    • /
    • pp.43-47
    • /
    • 2007
  • The polydiacethylene (PDA) is known to change its color by mechanical shear. The shear-induced color transition has been reported with elastomer or film type of PDA. In this paper, we newly investigated the transition with liposome type of PDAs in polymeric solutions. The liposomes were dispersed in Poly(vinyl alcohol) 2% + Sodium borate 1%, Poly(vinyl alcohol) 15% and Hyaluronic acid 1% (PVA/B, PVA, HA). The shear stress was continuously imposed to each solution by stress control type rheometer with coni-cylinder fixture. The degree of color transition was quantified with the characteristic absorbance peak at 540 nm (blue) and 640 nm (red). As a result, PDA liposome in PVA/B solution changed the color from blue to red upon increasing the magnitude of shear (from 0 to 100 Pa) and the duration of shear-imposed time (from 0 to 5400 sec). Meanwhile, PDA liposome in HA or PVA solution did not noticeably change the color, even though the low shear viscosities of the solutions were kept almost constant. This color transition of PDA liposome is expected to measure the magnitude of shear, and to distinguish different responses of polymeric solutions to the applied shear.

Microfluidic Fabrication of Conjugated Polymer Sensor Fibers (미세유동을 이용한 공액 고분자 센서 섬유 제작)

  • Yoo, Imsung;Song, Simon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.853-858
    • /
    • 2014
  • We propose a fabrication method for polydiacetylene (PDA)-embedded hydrogel microfibers on a microfluidic chip. These fibers can be applied to the detection of cyclodextrines (CDs), which are a family of sugar and aluminum ions. PDA, a family of conjugated polymers, has unique characteristics when used for a sensor, because it undergoes a blue-to-red color transition and nonfluorescence-to-fluorescence transition in response to environmental stimulation. PDAs have different sensing characteristics depending on the head group of PCDA. By taking advantage of ionic crosslinking-induced hydrogel formation and the 3D hydrodynamic focusing effect on a microfluidic chip, PCDA-EDEA-derived diacetylene (DA) monomer-embedded microfibers were successfully fabricated. UV irradiation of the fibers afforded blue-colored PDA, and the resulting blue PDA fibers underwent a phase transition to red and emitted red fluorescence upon exposure to CDs and aluminum ions. Their fluorescence intensity varied depending on the CDs and aluminum ion concentrations. This phase transition was also observed when the fibers were dried.

Development of the PDA Based Mobile System for Body Fat Measurement and Diagnosis Using Bioelectrical Impedance Method (체임피던스 방법을 이용한 PDA 기반의 휴대용 체지방 측정 및 진단 시스템 개발)

  • 권세윤;이상민;김재환;우지환;김인영;이형기;방석원;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Recently, many people want to know their state of health, such as a body fat rate, anywhere and anytime. The Personal Digital Assistance(PDA) is the portable wireless apparatus that has become widely popular. There are many application areas of the IDA to be in mobile care devices. In this study, we developed the PDA based body fat measurement system, composed of a cradle type measurement module and a WindowCE operated software module, a regression equation for predicting lean body mass (LBM). Sixty-three weight-stable subjects (53 men, 10 women) aged 20∼32yr participated in this study. A regression model, LBM = (0.0005*Height2 - 0.0160*Impedance + 0.3920*Weight - 0.0684*Age - 5.8141*Sex + 25.984, was found. The correlation coefficient( r) of body fat rate between developed system and HTM1000plus(BionetTM) was 0.928. HTM1000plus is a commercially available and approved by KFDA. These results indicated that developed system is reliable for estimation of body fat rate. Although developed system is the PDA based miniaturized, it shows good performance comparing with other commercial product.

Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus (원통형 모양 동맥관의 경피적 폐쇄술에서의 Amplatzer Vascular Plug 의 사용)

  • Choi, Eun-Young;Jang, So-Ick;Kim, Soo-Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.9
    • /
    • pp.1035-1037
    • /
    • 2009
  • Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tubular-type PDAs are difficult to close with ordinary detachable coils or the Amplatzer Duct Occluder; thus, these lesions remain a challenge for transcatheter closure. We attempted to occlude a tubular-type PDA by using an oversized Amplatzer Vascular Plug, which allowed intraluminal packing of the ductus. By using this treatment method, PDA occlusion was achieved safely with an excellent final outcome. We suggest that this approach may be a good option for transcatheter closure of a tubular-type PDA.

PDA-Based Software Development for Forest Inventory Data (PDA기반의 산림자원조사용 소프트웨어 개발에 관한 연구)

  • Lee, Heonho;Lee, Dohyung;Suk, Sooil
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.6
    • /
    • pp.690-695
    • /
    • 2006
  • This study was carried out to develop a system for forest resources inventory using PDA. The Forest Inventory Software running on PDA was developed based on a Forest Resources Inventory Method by Korea Forestry Service and 4th National Forest Inventory Method. The forest inventory data stored in PDA contains sea level and GPS positioning data. Forest inventory input items are 34 tree species, 18 diameter class by each tree species, number of trees, tree height per each diameter class, thickness of bark, and annual growth of tree. Application test of the software with the forest workers shorted that, hours of forest works were remarkably reduced. It is possible to do forest inventory effectively using Forest Inventory Software developed by this study. Therefore, investigation and management expenses can be reduced and labor productivity will be improved.

Pulmonary Hypertension in a Dog after Embolic Coil Placement for Interventional Occlusion of Patent Ductus Arteriosus (동맥관 개존증 개에서 색전 코일의 중재적 시술 후 발생한 폐성 고혈압)

  • Lee, Bareun;Kim, Jiyoun;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.507-510
    • /
    • 2014
  • An 8 month-old female Pomeranian dog was presented with major complaints of heart murmur and cardiomegaly. Diagnostic study found the left-to-right patent ductus arteriosus (PDA) with moderate heart failure (ISACHC II). The PDA occlusion was successfully accomplished using a $5mm{\times}3loops$ embolic coil through right femoral artery. Two months later, the dog came back to clinic with marked hypotension, severe diarrhea and pleural effusion. Diagnostic study found severe pulmonary hypertension and tricuspid regurgitation. The clinical condition was controlled by the administration of sildenafil (3 mg/kg, PO, TID). However, the dog was expired by dislodged embolic coil and inconsistent medication by the owner. Postmortem study found the pulmonary hypertension was occurred by the abnormally dislodged embolic coil. Although the embolic coil is widely used for PDA occlusion in toy dogs with PDA, the more careful evaluation for the size and shape of PDA is necessary to minimize the risk of dislodgement of pre-placed coil.

Measurement and Analysis of Performance to Transfer Data in a Wireless-Cum-Wired Intra-Network (유무선 통합 인트라넷 환경에서 데이터 전송 성능 측정 및 분석)

  • Hur Hye-Sun;Hong Youn-Sik;Woo Yo-Seop
    • Journal of Internet Computing and Services
    • /
    • v.5 no.3
    • /
    • pp.99-108
    • /
    • 2004
  • We have designed and implemented a Voice Messenger System(VMS) for sending and receiving voice data in order to measure and analyze the performance of a multimedia data transfer system using PDAs(Personal Digital Assistants) in a fast wireless LAN environment. The VMS has been configured as an infrastructure network by integrating a wireless intra-network based on IEEE 802,11 b standard with a wired network based on Ethernet. A sending time, a receiving time and a round-trip time(RTT) have been measured by varying its pecket size from 256 to 6656 bytes, Besides, we have performed the experiments to see which NIC is more stable between CF and PCMCIA type in such a wireless LAN environment, The results of such experiments show that the NIC with PCMClA type is better than that with CF type from the points of both efficiency and stability. The performance of a notebook computer with the attachment of a wireless NIC that is used as a VMS client is almost constant by varying its packet size when transferring voice data. However, with PDA client, in the case of receiving packets from the VMS server, the performance is the best when the pecket size is 6656 bytes, In addition, in the case of sending packets from PDA client to the VMS server, the performance is the best when the packet size is 4096 bytes. Even with the same pecket size, the time of receiving packets from the VMS server to PDA is longer than the time of sending packets from PDA to the VMS Server, Thus, we conclude that when PDA is used as a client by applying different pecket size when sending and receiving packets should be achieved a better performance over a wireless LAN environment.

  • PDF

Implementation of PACS using PDA System on Medical Images (PDA기반 의료영상의 전송시스템 구현)

  • Ji, Yeon-Sang;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.247-253
    • /
    • 2009
  • PACS(Picture archiving communication system) is a system that enables medical images such as X -ray, CT, MRI, PET to be stored electronically viewed on computer screens so that doctors and other authorized people can access search the information as needed. But if they are not in hospital area for example on holiday or at night, that are not able to access the PACS system instantly. We have to solve this problem for more efficient patient care. So we try to suggest a method that use the PDA system that wireless LAN and CDMA cellular phone are equipped. This system may help to access easier to PACS system regardless of the location and can also attribute the development of telemedicne.

I-PDA Controller Designed by CDM

  • Numsomran, Arjin;Sriratana, Witsarut;Julsereewong, Prasit;Kongratana, Viriya;Tirasesth, Kitti
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.284-287
    • /
    • 1999
  • A design of I-PDA controller for the third order plant by CDM is presented in this paper. Using CDM in the controller design procedures, the step responses of the controlled system with the I-PDA controller satisfied both transient and steady state response specifications without adjustment, and also satisfy the requirements of stability, faster response and robustness. The step responses of the controlled system using I-PDA controller are coiniciding to the ones using PIDA controller, and the integral gain of the I-PDA controller also equals to the prefilter gain of the PIDA controller designed by CDM. The effect of the disturbances can also be lastly eliminated. The fast step response of the controlled system can be obtained by reducing the equivalent time constant. MATLAB's numerical results show that the desired specifications of the controlled system using I-PDA controller is obtained. Furthermore, the results also show a good robustness that the desired performances of the controlled system have no significant changed when the plant parameters are varied.

  • PDF