• 제목/요약/키워드: 5 large load

검색결과 671건 처리시간 0.03초

지하대수층을 이용한 축열시스템의 설계 (I) : 등온해석 (Design of an Aquifer Thermal Energy Storage System (I) : Isothermal Analysis)

  • 송영길;이관수;이태희;김양현
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.102-110
    • /
    • 1993
  • An isothermal analysis was conducted to develop the design tool of an aquifer thermal energy storage system. Taejeon aquifer was chosen for the analysis, and the variation of FRE(Fluid Recovery Efficiency) with respect to the aquifer natural velocity and thermal load were investigated. The analysis results were compared with those of ATESSS(Aquifer Thermal Energy Storage System Simulator) and agreed within 2% of discrepancy. It is recommended, based on the result of this study, that the system may be suitable for a large volume of hot or chill thermal energy storage system, such as for district heating or cooling.

  • PDF

건축물의 내진설계에서 정적 비선형해석의 적용과 오차에 대한 고찰 (State-of-art on Its Application and Errors in Pushover Analysis of Building Structures)

  • 전대한;송호산
    • 한국공간구조학회논문집
    • /
    • 제5권1호
    • /
    • pp.99-105
    • /
    • 2005
  • The pushover analysis is becoming a popular tool for seismic design of building structures. In this paper the state-of-art on static nonlinear analysis of building structures is presented with the emphasis on the effects of analysis parameters; i. e., lateral load patterns, modeling of members, and analysis computer programs. The analysed results may have variation even if a same structure is analysed. This paper is to investigate how large the variation is and what the main causes of the variation are. The difference of analysed results, the resultant variation of lateral story shear force and flexural strength of structural members are discussed. The pushover analysis procedure are routinely used in the seismic design of building structures, but some problems must yet be clarified, such as the effects to evaluate the parameters of analysis on the basis of a lateral load patterns and modeling of members.

  • PDF

디젤기관의 속도제어성능 개선에 관한 연구 (A Study on the Improvement of the Speed Control Performance in a Diesel Engine)

  • 김병덕;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권5호
    • /
    • pp.33-43
    • /
    • 1993
  • Recent marine propulsion diesel engines tend to become slower in speed and longer in stroke for the higher engine efficiency, and in these long stroke and slow speed engines the digital governors are highly recommended to be used. But, in the present digital governors only the feedback of the engine rpm-signal is used for the engine speed control and it does not work so effectively when the load variation is large. In this paper, a new method is proposed to improve the speed control performance in a diesel engine, by adding the torque feedback loop to the present digital governor which uses the rpm feedback PID controller only. And also a method is proposed to adjust the parameters of the PID controller optimally.

  • PDF

Floating offshore wind turbine system simulation

  • ;박현철;정진화;김창완;김영찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.466-472
    • /
    • 2009
  • Offshore wind energy is gaining more and more attention during this decade. For the countries with coast sites, the water depth is significantly large. This causes attention to the floating wind turbine. Offshore wind turbines are designed and analyzed using comprehensive simulation codes that account for the coupled dynamics of the wind inflow, aerodynamics, elasticity and controls of the wind turbine, along with the incident waves, sea current, hydrodynamics, and foundation dynamics of the support structures. In this work, a three-bladed 5MW upwind wind turbine installed on a floating spar buoy in 320m of water is studied by using of fully coupled aero-hydro-servo-elastic simulation tool. Specifications of the structures are chosen from the OC3 (Offshore Code Comparison Collaboration) under "IEA Wind Annex XXIII-subtask2". The primary external conditions due to wind and waves are simulated. Certain design load case is investigated.

  • PDF

에스컬레이터의 구조적 진동 : (II) 분석 및 대책 (Structural vibration in Escalators :(II) Analysis and Countermeasure)

  • 임수영;권이석;박선용;홍성욱
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.830-837
    • /
    • 2000
  • This paper deals with an analysis and countermeasure of escalator vibration. The vibration characteristics of escalators are studied theoretically and experimentally to fine the main cause of severe vibration. The main source of vibration in escalators is found to be chordal effect due to the step chain and sprocket system. It is also found that the vibration become significantly large at so called no load condition, in which the load due to passengers, during down-moving, is equal to the resistive force in the driving system. Dynamic absorbers are implemented to suppress the vibration, A theoretical analysis is made to determine the appropriate dynamic absorber. Theoretical and experimental study shows that dynamic absorber is effective to suppress the vibration in escalators.

  • PDF

단조 반복하중이 작용하는 합성슬래브의 거동에 대한 실험적 연구 (An Experimental Study of the Composite Slab under a Repeated Loading)

  • 엄철환;김희철;박진영;서상훈
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.143-148
    • /
    • 2007
  • The application of metal deck floor system is increasing gradually and especially for office buildings. In the cases of large parking structures and storage structures, the construction period and the cost can be reduced. Also the steel deck system can prevent the crack of a floor and reduce the retrofit expenses. However, the floor should stand for the repeated truck load which is relatively heavier repeated loading. The mechanical behavior of a slab under repeated load is also different from the static loading state. An evaluation of a structural capacity was performed in this study through the dynamic capacity evaluation experiment for an application of a composite deck floor system as a parking structure slab. The period of repeated loadings were set up as 25years and 960,000 times monotone cyclic loads were applied at the center of the specimens. The tension crack propagation and patterns at the center of specimens were examined.

충돌에 의한 차체 박육구조부재의 에너지 흡수특성에 관한 연구 (An Energy Absorption Characteristic of Thin-Walled Structure Members by Crushing Load)

  • 양인영;심재기;김선규
    • 한국자동차공학회논문집
    • /
    • 제3권5호
    • /
    • pp.74-81
    • /
    • 1995
  • In this paper, the crushing tests of circular tubes under axial impact loading are conducted to investigate the energy absorption abilities. A cross head with 18kg launched by the compressed air collides against circular tubes. Circular tubes used for this experiment are Al and CFRP laminates, which have 8 ply with $15^{\circ}$ and $45^{\circ}$. The absorbed energy unit mass and volume of the CFRP specimen with $15^{\circ}$ are higher than those of aluminum specimen. CFRP specimen having small stacking angle have better energy absorption abilities than that of large stacking angle.

  • PDF

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

유량 및 부하가 변하는 상태에서의 양로드 유압실린더의 위치제어시스템 (Position Control System of a Double-end Rod Hydraulic Cylinder under Variable Flow Rate and Load Conditions)

  • 김대철;김동화;이재규;신범수
    • Journal of Biosystems Engineering
    • /
    • 제34권5호
    • /
    • pp.331-341
    • /
    • 2009
  • A double-end rod hydraulic cylinder is widely used with a steering valve for the steering control system in large tractors. For the development of automatic steering controller, the feasibility of using a proportional control valve replacing the conventional manual steering valve to control the position of hydraulic steering cylinder was investigated in terms of the max. overshoot, the steady-state error and the rise time. A simulation model for the electrohydraulic steering system with load using AMESim package was developed to be valid so that the proper control algorithm could be chosen through the computer simulation. It could be concluded that the P-control algorithm was sufficient to control the electrohydraulic steering system, where the control frequency should be no greater than 20 Hz at the P-gain of 5. In particular, the performance of the developed steering controller was satisfactory even at the conditions of varying flow rates and loads.

에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석 (An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment)

  • 박선효;권경우;손장열
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.392-397
    • /
    • 2010
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about 10.5~11.3%, and cooling loads are decreased about 29.1~38.3% on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades and the cooling peak load was reduced about 25.7~31.5%. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.