• Title/Summary/Keyword: 4DCT

Search Result 316, Processing Time 0.024 seconds

A Study on the Flow Path Position Design of Waviness Friction Pad for Drag Torque Reduction in Wet Type DCT (파형 습식클러치의 드래그 토크 저감을 위한 파형내 유로 위치 설정 설계 연구)

  • Cho, Junghee;Han, Juneyeol;Kim, Woojung;Jang, Siyoul
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Drag torque reduction in a wet clutch pack is a key aspect of the design process of the dual clutch transmission (DCT) system. In order to reduce the drag torque caused by lubricant shear resistance, recently developed wet clutch pack systems of DCT, as well as automatic transmission and other four-wheel drive (4WD) couplings, frequently utilize wavy wet clutch pads. Therefore, wavy shape of friction pad are made on the groove patterns like waffle pattern for the reduction of drag torque. Additionally, the groove patterns are designed with larger channels at several locations on the friction pad to facilitate faster outflow of lubricant. However, channel performance is a function of the waviness of the friction pad at the location of the particular channel. This is because the discharge sectional area varies according to the waviness amplitude at the location of the particular channel. The higher location of the additional channel on the friction pad results in a larger cross-sectional area, which allows for a larger flow discharge rate. This results in reduction of the drag torque caused by the shear resistance of DCTF, because of marginal volume fraction of fluid (VOF) in the space between the friction pad and separator. This study computes the VOF in the space between the friction pad and separator, the hydrodynamic pressure developed, and the shear resistance of friction torque, by using CFD software (FLUENT). In addition, the study investigates the dependence of these parameters on the location and waviness amplitude of the channel pattern on the friction pad. The paper presents design guidelines on the proper location of high waviness amplitude on wavy friction pads.

The Analysis of Predictive Factors for the Identification of Patients Who Could Benefit from Respiratory-Gated Radiotherapy in Non-Small Cell Lung Cancer (비소세포성 폐암에서 호흡동기방사선치료 적용 환자군의 선택을 위한 예측인자들의 분석)

  • Jang, Seong-Soon;Park, Ji-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.228-239
    • /
    • 2009
  • Purpose: 4DCT scans performed for radiotherapy were retrospectively analyzed to assess the possible benefits of respiratory gating in non-small cell lung cancer (NSCLC) and established the predictive factors for identifying patients who could benefit from this approach. Materials and Methods: Three treatment planning was performed for 15 patients with stage I~III NSCLC using different planning target volumes (PTVs) as follows: 1) PTVroutine, derived from the addition of conventional uniform margins to gross tumor volume (GTV) of a single bin, 2) PTVall phases (patient-specific PTV), derived from the composite GTV of all 6 bins of the 4DCT, and 3) PTVgating, derived from the composite GTV of 3 consecutive bins at end-exhalation. Results: The reductions in PTV were 43.2% and 9.5%, respectively, for the PTVall phases vs. PTVroutine and PTVgating vs. PTVall phases. Compared to PTVroutine, the use of PTVall phases and PTVgating reduced the mean lung dose (MLD) by 18.1% and 21.6%, and $V_{20}$ by 18.2% and 22.0%, respectively. Significant correlations were seen between certain predictive factors selected from the tumor mobility and volume analysis, such as the 3D mobility vector, the reduction in 3D mobility and PTV with gating, and the ratio of GTV overlap between 2 extreme bins and additional reductions in both MLD and $V_{20}$ with gating. Conclusion: The additional benefits with gating compared to the use of patient-specific PTV were modest; however, there were distinct correlations and differences according to the predictive factors. Therefore, these predictive factors might be useful for identifying patients who could benefit from respiratory-gated radiotherapy.

Zigbee Transmitter Using a Low-Power High-Gain Up-Conversion Mixer (저 전력 고 이득 주파수 상향변환기를 이용한 Zigbee 송신기 설계)

  • Baik, Seyoung;Seo, Changwon;Jin, Ho Jeong;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.9
    • /
    • pp.825-833
    • /
    • 2016
  • This paper introduces a direct-conversion CMOS RF transmitter for the IEEE 802.15.4 standard with a low-power high-gain up-conversion mixer designed in $0.18{\mu}m$ process. The designed RF DCT(Direct Conversion Transmitter) is composed of differential DAC(Digital to Analog Converter), passive low-pass filter, quadrature active mixer and drive amplifier. The most important characteristic in designing RF DCT is to satisfy the 2.4 GHz Zigbee standard in low power. The quadrature active mixer inside the proposed RF DCT provides enough high gain as well as sufficient linearity using a gain boosting technique. The measurement results for the proposed transmitter show very low power consumption of 7.8 mA, output power more than 0 dBm and ACPR (Adjacent Channel Power Ratio) of -30 dBc.

Design of EPG Information Player System using DCT based Blind Watermark (DCT기반의 블라인드 워터마크를 이용한 EPG 정보 재생기 설계)

  • Kim, Dae-Jin;Choi, Hong-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.1-10
    • /
    • 2011
  • While the broadband network and multimedia technologies have been developing, the commercial market of digital contents has also been widely spreading with recently starting IPTV. Generally, PC player can display digital contents obtained through middleware like a settop box and can only bring the informations about contents like CODEC, bitrate etc. useful for only experts. But general users want to know more optional informations like content's subject, description etc. So unlike previous PC player, we proposed a player system that can get inserted informations, namely EPG(Electronic Program Guide), without database after bringing contents to PC through settop box. In addition, we also proposed DCT(Discrete Cosine Transform) based blind watermark generating method to insert EPG informations. We can extract watermark without original image and insert robust watermark in proportion to coefficients in frequency domain. And we analyzed and parsed PSI data from MPEG-TS. So we could insert wanted information using watermark from EPG. And we composed UI by extracting EPG information from watermark interted contents. Finally we modularized whole system into the watermark insert/extract application and directshow filter based player. So we tried to design this system so that the general developer can do in a way that is easier and faster.

An Evaluation Validity of the Silicone Replica Technique at Measurement on Fit of Fixed Dental Prostheses (고정성 보철물의 적합도 측정 시 사용하는 실리콘 복제본 기술의 정확도 평가)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.566-571
    • /
    • 2012
  • Marginal and internal fit are very important factor for the clinical long-term success of fixed dental prostheses (FDPs). A variety of methods have been applied to the measuring marginal and internal fit of FDPs. The purpose of this study was to compare the marginal and internal fit of 2 different measuring methods silicone replica technique [SRT] and die cutting technique (DCT). SRT, the space between die and FDPs were filled with light-body silicone, then stabilized by medium-body silicone. DCT, the FDPs were cemented on definitive dies and embedded into epoxy. The silicone replicas and epoxies were sectioned mesio-distal and measured 4 locations (margin, rounded chamfer, axial, occlusal) and using a digital microscope at a magnification $\times$160. For the SRT the mean${\pm}$SDs fit (${\mu}m$) recorded were: margin $88.7{\pm}22.2$, rounded chamfer $90.6{\pm}25.0$, axial wall $61.5{\pm}21.8$, occlusal $134.9{\pm}30.8$. For the DCT the mean${\pm}$SDs fit (${\mu}m$) recorded were: margin $85.3{\pm}18.0$, rounded chamfer $85.4{\pm}24.7$, axial wall $62.0{\pm}21.3$, occlusal $131.7{\pm}30.5$. The mean${\pm}$SDs size (${\mu}m$) of SRT margin was $88.7{\pm}22.2$ and of DCT margin was $85.3{\pm}18.0$. There were no statistically significant difference (p<0.05) of the four parts between SRT and DCT. It is considered an appropriate case to use SRT at fit of FDPs.

Digital Watermark Based Error Detection for MPEG-4 Bitstream Error

  • Hiroyuki Okada;Shiitev, Altan-Erdene;Song, Hak-Sop;Gen Fujita;Takao Onoye;Isao Shirakawa
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.152-155
    • /
    • 2002
  • In this paper, a new approach is proposed for the error detection dedicated to MPEG-4 video coding by using the digital watermarking. In the process of encoding, the proposed scheme abstracts the macroblock features of headers, motion vectors, and Discrete Cosine Transform (DCT) coefficients, which are embedded in the quantized DCT coefficients as the digital watermarks. The decoder performs the accurate error detection through the watermark extraction. Simulation results demonstrate that the error detection ability of the proposed approach can be significantly enhanced, and that digital watermark embedding incurs little degradation to the picture quality.

  • PDF

Development of Digital Watermark Inserting and Detecting System for MPEG-2 Codec (MPEG-2 Codec에 대한 디지털 워터마크 삽입 및 검출 시스템 개발)

  • Hwang, Seon-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.390-394
    • /
    • 2010
  • This paper describes a study on developing an insert and detect system of digital watermark to the MPEG-2 coder and decoder. Digital watermark inserting system substitutes a coefficient among the DCT coefficients for new one. This replacement performs in MPEG-2 PS format. Watermark detecting system analyzes the input data stream of MPEG-2 and detect the probability of occurrence of a specific code or watermarking code. Our inserting system had very high invisibility and the PSNR of the results was 130 dB around. And our detection rate of watermark was over 99% in digital format and over 85% in analog captured format according to the quality of contents.

Noise Reduction Algorithm of Digital Hologram Using Histogram Changing Method (히스토그램 변환기법을 이용한 디지털 홀로그램의 잡음제거 알고리듬)

  • Choi, Hyun-Jun;Seo, Young-Ho;Kim, Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.603-610
    • /
    • 2008
  • In this paper, we propose an efficient noise reduction algorithm for digital hologram during acquisition and transmission. The proposed algorithm segment a digital hologram with object region and background region after DCT. Then, we adopt a histogram transition method for object region and zero-value change method for background region. The experimental results show that our algorithm has beuer performance than a natural image denoising algorithm.

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

Parallel Inverse Transform and Small-sized Inverse Quantization Architectures Design of H.264/AVC Decoder (H.264/AVC 복호기의 병렬 역변환 구조 및 저면적 역양자화 구조 설계)

  • Jung, Hong-Kyun;Cha, Ki-Jong;Park, Seung-Yong;Kim, Jin-Young;Ryoo, Kwang-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.444-447
    • /
    • 2011
  • In this paper, parallel IT(inverse transform) architecture and IQ(inverse quantization) architecture with common operation unit for the H.264/AVC decoder are proposed. By using common operation unit, the area cost and computational complexity of IQ are reduced. In order to take four execution cycles to perform IT, the proposed IT architecture has parallel architecture with one horizontal DCT unit and four vertical DCT units. Furthermore, the execution cycles of the proposed architecture is reduced to five cycles by applying two state pipeline architecture. The proposed architecture is implemented to a single chip by using Magnachip 0.18um CMOS technology. The gate count of the proposed architecture is 14.3k at clock frequency of 13MHz and the area of proposed IQ is reduced 39.6% compared with the previous one. The experimental result shows that execution cycle the proposed architecture is about 49.09% higher than that of the previous one.

  • PDF