• Title/Summary/Keyword: 48-V power supply system

Search Result 23, Processing Time 0.027 seconds

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.V.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3114-3116
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%] of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.902-904
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2462-2464
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a Practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1820-1822
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Power supply system of the telecommunication equipment with monitoring function (모니터 기능을 갖는 통신기기용 전원 시스템)

  • Lee, Jung-Kee;Kim, Young-Tae;Kim, Chang-Sun;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.309-311
    • /
    • 1995
  • Recently, a power supply system of the telecommunication equipments with monitoring function has been widely studied. In the power supply system which is apart from the central station, it is required to check and test the operating states of the system at the central station. In this paper, the power supply system with monitoring function is discussed. In the system, the Full-Bridge converter is designed as a power supply and it has the ratings of DC 280-340V input and DC 48V, 480W output. And the monitoring part of the system is composed of a voltage and current sensing unit A/D converter, I/O card, and a personal computer. The operating states of the system is monitored by checking the voltage and current variation at input and output, and it is represented by graphical modes. By conducting the experiment, it is confirmed that the operating states of the system is well monitored.

  • PDF

Performance Analysis of Heating Nonslip using Solar Power Energy (태양광 에너지를 이용한 발열논슬립의 성능분석)

  • Moon, Jong Wook;Choe, Jae Won;Yun, Seok Heon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.55-61
    • /
    • 2018
  • This study aims to analyze the performance of Heated-nonslip using renewable energy to prevent nonslip freezing during winter. For this purpose, power generation system and congratulatory devices using solar energy are designed, and it is designed to provide regular electricity to heat up nonslip through Electrical storage system(ESS). In this study, It is intended to analyze the level of electrical energy suitable for nonslip using 24V or 48V, and to measure the temperature changes and temperature distribution according to the location of the test object. As a result of the experiment, nonslip's frame temperature was measured at $-7.5{\sim}-5^{\circ}C$ on average, and $-1{\sim}-2^{\circ}C$ on the heating cable during the supply of 24V and this could not be the solution for defrosting freezing nonslip in the winter. As a result of heating nonslip by supplying 48V with an electrical power of 8W, the temperature of the nonslip was shown to be between $5^{\circ}C$ and $11^{\circ}C$ to $13^{\circ}C$. Even if the power supply was switched on and off every minute, the temperature did not drop below $4^{\circ}C$ and the frozen ice melted on the nonslip without freezing.

600W PV ESS with DC power supply function (DC전원공급 기능을 보유한 600W PV ESS)

  • Paeng, Seongil;Park, Unho;Lim, Yong-Bae;Choe, Gyu-ha
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.85-86
    • /
    • 2017
  • 본 논문에서는 DC 48V 전원 공급이 가능한 600W급 PV ESS( Energy Storage system)시스템에 대하여 제안한다. PV 입력부는 100V이하의 전압 입력에서 사용할 수 있도록 3레벨 부스트(Three level boost)컨버터로 구성하였다. 배터리는 양방향 DC/DC 컨버터를 사용하였고 DC48V부는 벅 컨버터로 구성하였다. 제안한 시스템의 검증하기 위하여 시뮬레이션과 600W PV ESS 시스템을 구성 실험을 진행하였다.

  • PDF

The Characteristics Analysis of New Dc 48[V] Telecommunication Power System using Forward Type three Phase Rectifier (포워드형 3선 PWM 정류기를 이용한 새로운 DC 48[V] 통신용 전원시스템의 특성 해석)

  • Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • This paper proposed power system for new DC 49[V] telecommunication using forward three-phase PWM rectifier power factor and efficiency for improvement of ripple voltage. Proposed power system for DC 48[V] telecommunication that consists of power conversion devices including switch, inductor and condenser were made between each line, in power inverter device of each switch control turn-on in period of continuity time control to get power factor '1' of sine wave current and on-off of switch lessens peak current that was happened and got conversion efficiency 92.1[%] composing in PWM rectifier of forward form instead of general PWM rectifier. Also, harmonic input regulation value(IEC61000-3-2 Class-As) satisfy input current and reduce ripple factor of output voltage in state that distortion of three-phase supply is overlapped each other.

A Fabrication and Testing of New RC CMOS Oscillator Insensitive Supply Voltage Variation

  • Kim, Jin-su;Sa, Yui-hwan;Kim, Hi-seok;Cha, Hyeong-woo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.2
    • /
    • pp.71-76
    • /
    • 2016
  • A controller area network (CAN) receiver measures differential voltage on a bus to determine the bus level. Since 3.3V transceivers generate the same differential voltage as 5V transceivers (usually ${\geq}1.5V$), all transceivers on the bus (regardless of supply voltage) can decipher the message. In fact, the other transceivers cannot even determine or show that there is anything different about the differential voltage levels. A new CMOS RC oscillator insensitive supply voltage for clock generation in a CAN transceiver was fabricated and tested to compensate for this drawback in CAN communication. The system consists of a symmetrical circuit for voltage and current switches, two capacitors, two comparators, and an RS flip-flop. The operational principle is similar to a bistable multivibrator but the oscillation frequency can also be controlled via a bias current and reference voltage. The chip test experimental results show that oscillation frequency and power dissipation are 500 kHz and 5.48 mW, respectively at a supply voltage of 3.3 V. The chip, chip area is $0.021mm^2$, is fabricated with $0.18{\mu}m$ CMOS technology from SK hynix.

Core Loss Effects on Electrical Steel Sheet of Wound Rotor Synchronous Motor for Integrated Starter Generator

  • Lee, Choong-Sung;Kim, Ji-Hyun;Hong, Jung-Pyo
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.148-154
    • /
    • 2015
  • 48-V ISG (Integrated Starter Generator) system has attracted attention to improve the fuel efficiency of ICE (Internal Combustion Engine) vehicle. One of the key components that significantly affects the cost and performance of the 48-V ISG system is the motor. In an ISG motor, the core and copper loss make the motor efficiency change because the motor has a broad driving operated range and more diverse driving modes compared with other motors. When designing an ISG motor, the selection of an electrical steel sheet is important, because the electrical steel sheet directly influences the efficiency of the motor. In this paper, the efficiency of the ISG motor, considering core loss and copper loss, is analyzed by testing different types of electrical steel sheets with respect to the driving speed range and mode. Using the results of a finite element method (FEM) analysis, a method to select the electrical steel sheet is proposed. This method considers the cost of the steel sheet and the efficiency according to driving mode frequency during the design process of the motor. A wound rotor synchronous machine (WRSM) was applied to the ISG motor in this study.