• Title/Summary/Keyword: 4-electrodes

Search Result 1,603, Processing Time 0.029 seconds

Measuring System of Visual Evoked Potential (VEP) in Mice using BioPAC Modules (BioPAC 모듈을 이용한 마우스 시각유발전위 측정 시스템 확립)

  • Lee, Wang Woo;Ahn, Jung Ryul;Goo, Yong Sook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.16-24
    • /
    • 2017
  • For the development of feasible retinal prosthesis, one of the important elements is acquiring proper judging tool if electrical stimulus leads to patient's visual perception. If evoked potential to electrical stimulus is recorded in primary visual (V1) cortex, it means that the stimulus effectively evokes visual perception. Therefore, in this study, we established VEP recording system on V1 cortex using BioPAC modules as the judging tool. And the measuring system was evaluated by recording VEP of mice. After anesthesia, normal mice (C57BL/6J strain; n = 6) were secured to stereotaxic apparatus (Harvard Apparatus, USA). For the recording of VEP, the stainless steel needle electrode (impedance: $2-5k{\Omega}$) was positioned on the surface of the cortex through the burr hole at 2.5 mm lateral and 4.6 mm caudal to bregma. DA 100C and EEG 100C BioPAC modules were used for the trigger signal and VEP recording, respectively. When left eye was blocked by black cover and right eye was stimulated by flash light using HMsERG (RetVet Corp, USA), VEP response at left V1 cortex was detected, but there was no response at right V1 cortex. Amplitudes and latencies of P2, N3 peaks of VEP recording varied according to the depths of the electrodes on V1 cortex. From the surface upto $600{\mu}m$ depth, amplitudes of P2 and N3 increased, while deeper than $600{\mu}m$, those amplitudes decreased. The deeper the insertion depth of the electrode, the latency of N1 peaks tends to be delayed. However, there was no statistically significant difference among the latencies of P2 and N3 peaks (P > 0.05, ANOVA). Our VEP recording data such as the insertion depth and the latency and amplitudes of peaks might be used as guidelines for electrically-evoked potential (EEP) recording experiment in near future.

Prediction of ground-condition ahead of tunnel face using electromagnetic wave - analytical study (전자기파를 이용한 터널전방 예측 -해석기법 중심으로)

  • Choi, Jun-Su;Cho, Gye-Chun;Lee, Geun-Ha;Yoon, Ji-Nam
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.4
    • /
    • pp.327-343
    • /
    • 2004
  • During tunnel construction, ground failures often occur due to existence of weak zones, such as faults, joints, and cavities, ahead of tunnel face. It is hard to detect effectively weak zones, which can lead underground structure to fail after excavation and before supporting, by using conventional characterization methods. In this study, an enhanced analytical method of predicting weak zones ahead of tunnel face is developed to overcome some problems in the conventional geophysical exploration methods. The analytical method is based on Coulomb's and Gauss' laws with considering the characteristics of electric fields subjected to rock mass. Using the developed method, closed form solutions are obtained to detect a spherical shaped zone and an oriented fault ahead of tunnel face respectively. The analytical results suggest that the presence of weak zones and their sizes, location, and states can be accurately predicted by combining a proper inversion process with resistance measured from several electrodes on the tunnel face. It appears that the skin depth or resistivity in rock mass is affected by the diameter of tunnel face, natural electric potential and noises induced by experimental measurement and spatial distribution of uncertain properties. The developed analytical solution is verified through experimental tests. About 1800 concrete blocks of 5cm by 5cm by 5cm in size are prepared and used to model a joint rock mass around tunnel face. Weak zones are simulated ahead of tunnel face with a material which has relatively higher conductivity than concrete blocks. Experimental results on the model test show a good agreement with analytical results.

  • PDF

Study on Color and Oxidation Thickness for Titanium Spectacle Frames Colored by Anodization (양극산화방법으로 착색한 티타늄 안경테의 산화막 두께에 따른 색상 연구)

  • Hyun, Seung-Cheol;Jin, Moon-Seog;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.33-37
    • /
    • 2009
  • Purpose: To examine the coloring condition of titanium spectacle frames with various colors by using anodization method. Methods: We made an anodization coater. Platinum plate with $3{\times}3cm^2$ was used for a cathode and titanium spectacle frame specimens was mounted on an anode in an electrolyte. An electric source device were designed to supply steady state current. The color of the coated spectacle frame specimens were measured by a spectrophotometer equipped with an integrating sphere. We use CIE $L^*a^*b$ color system as chromaticity coordinates. Results: The thickness of $TiO_2$ of titanium spectacle frame specimens was varied as controlling current flow time for electrodes. The specimens with various kinds of color as a walnut, a yellow brown, a navy blue, a blue, a light blue, a mung bean, a yellowish green, a light purple, a purple, a flower pink, a bluish green, an emerald, and a green color etc. were obtained. The values of CIE $L^*a^*b^*$ for these specimens were measured and analyzed to be changed clockwise in chromaticity coordinates as the thickness of $TiO_2$ increases. Conclusions: We identified the coloring mechanism by anodization method in titanium spectacle frame specimens.

  • PDF

Development of Epoxy Based Stretchable Conductive Adhesive (신축 가능한 에폭시 베이스 전도성 접착제 개발)

  • Nam, Hyun Jin;Lim, Ji Yeon;Lee, Chang Hoon;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.3
    • /
    • pp.49-54
    • /
    • 2020
  • To attach a stretchable/flexible electrode to something or something to on electrode, conductive adhesives must be stretchable/flexible to suit the properties of the electrode. In particular, conductive adhesive require durability and heat resistance, and unlike conventional adhesives, they should also have conductivity. To this end, Epoxy, which has good strength and adhesion, was selected as an adhesive, and a plasticizer and a reinforcement were mixed instead of a two-liquid material consisting of a conventional theme and a hardener, and a four-liquid material was used to give stretchability/flexibility to high molecules. The conductive filler was selected as silver, a material with low resistance, and for high conductivity, three shapes of Ag particles were used to increase packing density. Conductivity was compared with these developed conductive adhesives and two epoxy-based conductive adhesives being sold in practice, and about 10 times better conductivity results were obtained than products being actually sold. In addition, conductivity, mechanical properties, adhesion and strength were evaluated according to the presence of plasticizers and reinforcement agent. There was also no problem with 60% tensile after 5 minutes of curing at 120℃, and pencil hardness was excellently measured at 6H. As a result of checking the adhesion of electrodes through 3M tape test, all of them showed excellent results regardless of the mixing ratio of binders. After attaching the Cu sheet on top of the electrode through conductive adhesive, the contact resistance was checked and showed excellent performance with 0.3 Ω.

Measurements and Modeling of the Activity Coefficients and Solubilities of L-alanine in Aqueous Electrolyte Solutions (전해질 수용액에서 L-Alanine의 활동도계수와 용해도의 측정 및 모델링)

  • Lee, Bong-Seop;Kim, Ki-Chang
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.519-533
    • /
    • 2010
  • Activity oefficients and solubilities of L-Alanine in aqueous solutions containing each of four electrolytes(NaCl, KCl, $NaNO_3$ and $KNO_3$) were measured at 298.15 K. The measurements of activity coefficients were carried out in the electrochemical cell coupled with two ion-selective electrodes(cation and anion), and the solubilities were measured by the gravimetric analysis of saturated solutions in equilibrium with the solid phase of L-alanine. To model the activity coefficients and solubilities of amino acid in the amino acid/electrolyte aqueous solutions, thermodynamic relations of the residual Helmholtz free energy in the amino acid/electrolyte aqueous solutions were developed based on the perturbed-chain statistical associating fluid theory(PC-SAFT) combined with the primitive mean spherical approximation(primitive-MSA). In the present model, it is assumed that the zwitterions of L-alanine are associated with each other and cross-associated with water molecules, and also cross-associated with the cation and anion dissociated from an electrolyte(inorganic salt). The activity coefficients and solubilities of L-Alanine calculated from the theoretical model proposed in this work are found to be well agreeable with experimental data.

Gait Phases Detection from EMG and FSR Signals in Walkingamong Children (근전도와 저항 센서를 이용한 보행 단계 감지)

  • Jang, Eun-Hye;Chi, Su-Young;Lee, Jae-Yeon;Cho, Young-Jo;Chun, Byung-Tae
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.207-214
    • /
    • 2010
  • The aim of this study was to investigate upper and lower limb muscle activity using EMG(electromyogram) sensors while walking and identify normal gait pattern using FSR(force sensing resistor) sensor. Fifteen college students participated in this study and their EMG and FSR signal were measured during stopping and walking trials. EMG signals from upper(pectoralis major and trapezius) and lower limbs(rectus femoris, biceps femoris, vastus medialis, vastus lateralis, semimembranosus, semitendinosus, soleus, peroneus longus, gastrocnemius medialis, and gastrocnemius lateralis) were obtained using the surface electrodes. FSR measured pressures on 8 areas of the sole of the foot during walking. EMG results showed that all muscle activities except for vastus lateralis and semimembranosus during walking had higher amplitudes than stopping. Additionally, muscle activities associated with stance and swing phase during walking were identified. Results on FSR showed that stance and swing phases were detected by FSR signals during a gait cycle. Eight gait phases-initial contact, loading response, mid stance, terminal stance, pre swing, initial swing, mid swing, and terminal swing- were classified.

  • PDF

Gene Transfer in Normal and Ischemic Tibialis Anterior Muscle of Rat by In Vivo Electroporation

  • Kim, Ji-Sook;Shim, Hyung-Jin;Kim, Hong-Jin;Choi, Kyung-Hee;Kim, Jung-Woong;Kwak, Byung-Kook
    • Biomedical Science Letters
    • /
    • v.13 no.3
    • /
    • pp.207-212
    • /
    • 2007
  • The purpose of this preliminary study is to improve the efficiency of gene transfer of nonviral plasmid DNA by in vivo electroporation in ischemic hindlimb muscle, tibialis anterior. Hindlimb ischemic model was aseptically made by excision of left femoral artery. Each $50\;{\mu}g$ of pEGFP-C1 and pGL3-control in $100\;{\mu}l$ 0.9% NaCl was injected in tibialis anterior muscle. In vivo electroporation was applied on the same site with 10 mm-distance 2 needle array electrodes and ECM830. In 3 groups of normal rat with different electric field strength 0, 200 and 800 V/cm, the expression of pEGFP-C1 was comparatively evaluated. In 8 groups of normal rats, the expression of pGL3-control was evaluated in 0, 40, 50, 80, 100, 150, 200 and 300 V/cm of electric field strength. In 5 groups of ischemic models, the expression of pGL3-control was analyzed on 0, 4, 7, 10 and 14 days elapsed after making ischemic models. In 9 groups of ischemic rats, the expression of pGL3-control was analyzed in the electric field strength 0, 60, 70, 80, 100, 150, 200, 250 and 300 V/cm. GFP expressions in normal tibialis anterior were high in the extent and degree in order of electric field strength of 200, 800 and 0 V/cm. Luciferase value was highest in $50{\sim}100\;V/cm$ electric field strength. In the case of ischemic models, luciferase expression was significantly increasing in the order elapsed time after making the model. The degree of luciferase expression was higher in cases of application of in vivo electroporation than in that of non-application and was highest in $100{\sim}150\;V/cm$. In conclusion, in vivo electroporation is effective in transfer and expression of plasmid DNA in normal and ischemic tibialis anterior of rat.

  • PDF

Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

Study of Oxygen Plasma Effects to Reduce the Contact Resistance of n-type GaN with Nitrogen Polarity (질소 분극면을 갖는 N형 질화물반도체의 접촉저항 감소를 위한 산소 플라즈마 효과에 관한 연구)

  • Nam, T.Y.;Kim, D.H.;Lee, W.H.;Kim, S.J.;Lee, B.G.;Kim, T.G.;Jo, Y.C.;Choi, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.10-13
    • /
    • 2010
  • We studied the effect of $O_2$ plasma treatments on the electrical property of Ti / Al ohmic contacts to N-face n-type GaN. The surface of N-face, n-type GaN has been treated with $O_2$ plasma for 120 s before the deposition of bilayered electrodes, Ti (50 nm) / Al (35 nm), and its contact resistance was compared with that of the reference sample without $O_2$ plasma. As a result, we found that the ohmic contact was reduced from $4.3\;{\times}\;10^{-1}\;{\Omega}cm^2$ to $1.25\;{\times}\;10^{-3}\;{\Omega}cm^2$ by applying $O_2$ plasma on the surface of n-type GaN, which was attributed to the reduction in the Schottky barrier height (SBH), caused by nitrogen vacancies formed during the $O_2$ plasma process.

Development of an Improved Numerical Methodology for Design and Modification of Large Area Plasma Processing Chamber

  • Kim, Ho-Jun;Lee, Seung-Mu;Won, Je-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.221-221
    • /
    • 2014
  • The present work proposes an improved numerical simulator for design and modification of large area capacitively coupled plasma (CCP) processing chamber. CCP, as notoriously well-known, demands the tremendously huge computational cost for carrying out transient analyses in realistic multi-dimensional models, because electron dissociations take place in a much smaller time scale (${\Delta}t{\approx}10-8{\sim}10-10$) than time scale of those happened between neutrals (${\Delta}t{\approx}10-1{\sim}10-3$), due to the rf drive frequencies of external electric field. And also, for spatial discretization of electron flux (Je), exponential scheme such as Scharfetter-Gummel method needs to be used in order to alleviate the numerical stiffness and resolve exponential change of spatial distribution of electron temperature (Te) and electron number density (Ne) in the vicinity of electrodes. Due to such computational intractability, it is prohibited to simulate CCP deposition in a three-dimension within acceptable calculation runtimes (<24 h). Under the situation where process conditions require thickness non-uniformity below 5%, however, detailed flow features of reactive gases induced from three-dimensional geometric effects such as gas distribution through the perforated plates (showerhead) should be considered. Without considering plasma chemistry, we therefore simulated flow, temperature and species fields in three-dimensional geometry first, and then, based on that data, boundary conditions of two-dimensional plasma discharge model are set. In the particular case of SiH4-NH3-N2-He CCP discharge to produce deposition of SiNxHy thin film, a cylindrical showerhead electrode reactor was studied by numerical modeling of mass, momentum and energy transports for charged particles in an axi-symmetric geometry. By solving transport equations of electron and radicals simultaneously, we observed that the way how source gases are consumed in the non-isothermal flow field and such consequences on active species production were outlined as playing the leading parts in the processes. As an example of application of the model for the prediction of the deposited thickness uniformity in a 300 mm wafer plasma processing chamber, the results were compared with the experimentally measured deposition profiles along the radius of the wafer varying inter-electrode gap. The simulation results were in good agreement with experimental data.

  • PDF