• 제목/요약/키워드: 4 inch)

검색결과 531건 처리시간 0.027초

레이저 간섭 리소그래피를 이용한 대면적 나노 구조체 제작 (Large Area Nanostructure Fabrication by Laser Interference Lithography)

  • 정일규;김종석;한재원;이성호
    • 반도체디스플레이기술학회지
    • /
    • 제11권1호
    • /
    • pp.7-11
    • /
    • 2012
  • One dimensional and two dimensional nano patterns were fabricated on a 4-inch substrate by Laser Interference Lithography (LIL). Mach-Zehnder interferometer was setup to obtain the interference patterns and adjusted the pattern sizes with change of incident angle. We could obtain a periodic structure with a period of 440 nm using 266 nm laser, and demonstrated a pattern size with $293{\pm}25nm$ over a 4-inch substrate.

미국면과 한국면의 생산량 및 특성 비교 (The Investigation compared with Productivity and Properties on American Cotton and Korean Cotton)

  • 이광우
    • 한국의류산업학회지
    • /
    • 제1권3호
    • /
    • pp.275-279
    • /
    • 1999
  • The purpose of this study was to investigate a specific character on products of Korean cotton and American cotton with cultivated in sangju city, Korea. The results of this study were as follows: Productivity of American cotton was nine times higher than those of Korean cotton. Spinning coefficient index (SCI: 140), strength (32.6 g/tex), fiber length (1.12 inch), uniformity index (83.4%), short fiber index (6.4), color grade (21) of American cotton was superior than SCI (122), strength (27.7 g/tex), fiber length (1.02 inch), uniformity index(81.1 %), short fiber index (10.6), color grade (23) of Korean cotton. Microaire (3.5), elongation (6.9%) of Korean cotton was superior than American cotton.

  • PDF

탕침 온도에 따른 닭고기의 저장성 및 품질 변화 (Effect of the Scalding Temperature at Slaughtering Process on Meat Quality and Storage Properties of Chicken)

  • 채현석;안종남;유영모;박범영;함준상;김동훈;이종문;최양일
    • 한국축산식품학회지
    • /
    • 제24권2호
    • /
    • pp.115-120
    • /
    • 2004
  • 도계과정에서 탕침 온도를 저온(53-55$^{\circ}C$), 중온(59-61$^{\circ}C$), 고온(65-67$^{\circ}C$)으로 변화시켰을 때 닭고기의 육질에 미치는 영향과 저장 특성을 구명하고자 실시하였다. 탕침 온도가 높을수록 피부의 황색도(b$^{*}$ )는 감소하는 경향을 나타냈으며, 물리적 변화에서 보수력은 저온(67.043%)에서 고온(69.26%)으로 온도가 높아질수록 증가하는 경향을 나타냈다. 전단력은 저온(1.70kg/0.5inch$^2$)보다 고온 (2.54kg/0.5 inch$^2$)으로 높아질수록 유의적으로(p<0.05) 증가하였다. 저장 3일에 저온 탕침 처리 닭고기의 지방산패도(TBARS) 값은 저온 0.25, 중온 0.24, 고온 0.27mg MA/kg으로 중, 저온에서는 비슷한 경향을 나타났으나 고온에서는 약간 증가한 것으로 나타났다. 총세균수는 저온에서 4.99, 중온 4.88, 고온 4.05 log CFU/mL를 나타나 탕침 온도가 높아질수록 감소하는 경향을 나타내었으나 유의적인 차이는 없었다(p<0.05). 도체 조사에서 깃털의 출현율은 탕침 온도가 높아지면서 큰 것(1cm 이상)은 중온(59-61$^{\circ}C$)부터 현저히 감소하는 경향을 나타냈으나 중온과 고온에서는 차이가 거의 없었다. 외상은 탕침 온도가 61$^{\circ}C$ 이하인 저온, 중온에서는 0.6cm를 나타냈으나 고온처리에서는 7 cm로 급격히 증가하여서 고온처리에 따른 피부의 손상이 심한 것으로 나타났다. 이상의 결과는 탕침 온도가 너무 낮을 경우는 육색 및 물리적 특성은 양호하나 미생물이 증가하고, 깃털이 잘 뽑히지 않는 단점이 있으며, 고온일 경우는 황색도(b$^{*}$ )가 낮아지는 경향을 나타내며, 도체에서 깃털은 잘 뽑혔으나 표피 손상으로 근육의 노출이 많았다.

RCGVS Design Improvement and Depressurization Capability Tests for Ulchin Nuclear Power Plant Units 3 and 4

  • Sung, Kang-Sik;Seong, Ho-Je;Jeong, Won-Sang;Seo, Jong-Tae;Lee, Sang-Keun;Keun hyo Lim;Park, Kwon-Sik;Oh, Chul-Sung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.417-422
    • /
    • 1998
  • he Reactor Coolant Gas Vent System(RCGVS) design for Ulchin Nuclear Power Plant Units 3&4(UCN 3&4) has been improved from the Yonggwang Nuclear Power Plant Units 3&4(YGN 3&4) based on the evaluation results for depressurization capability tests performed at YGN 3&4. There has been a series of plant safety analyses for Natural Circulation Cooldown(NCC) event and thermo-dynamic analyses with RELAP5 code for the steam blowdown Phenomena in order to optimize the orifice size of UCN 3&4 RCGVS. Baesd on these analyses results, the RCGVS orifice size for UCN 3&4 has been reduced to 9/32 inch from the l1/32 inch for YGN 3&4. The depressurization capability tests, which were performed at UCN 3 in order to verify the FSAR NCC analysis results, show that the RCGVS depressurization rates are being within the acceptable ranges. Therefore, it is concluded that the orificed flow path of UCN 3&4 RCGVS is adequately designed, and can provide the safety-grade depressurization capability required for a safe plant operation.

  • PDF

교정용 브라켓의 종류와 각도, 호선의 코팅 여부에 따른 마찰력의 비교 (The comparison of the frictional force by the type and angle of orthodontic bracket and the coated or non-coated feature of archwire)

  • 장태호;김상철;조진형;채종문;장나영;강경화
    • 대한치과교정학회지
    • /
    • 제41권6호
    • /
    • pp.399-410
    • /
    • 2011
  • 본 연구의 목적은 코팅된 호선, 다양한 브라켓, 그리고 브라켓-호선 각도가 교정용 호선이 브라켓을 활주 이동하는 동안 발생되는 마찰력에 어떠한 영향을 미치는지에 대하여 평가해보는 것이었다. 고정식 장치를 이용한 교정치료 시발생할 수 있는 상황을 시뮬레이션하기 위하여 4종류의 브라켓(금속 브라켓인 Micro-arch, 단결정 세라믹 브라켓인 Perpect Clear2, active type의 자가결찰 브라켓인 Clippy-C, passive type의 자가결찰 브라켓인 Damon3)과 5종류의 교정용 호선(0.014", 0.016", 0.016" ${\times}$ 0.022" inch coated Ni-Ti 호선, 0.016", 0.016" ${\times}$ 0.022" inch Ni-Ti 호선)이 사용되었고 브라켓-호선 각도는 각각 $0^{\circ}$, $3^{\circ}$, $6^{\circ}$, $9^{\circ}$로 조절되었다. 모든 실험군에서 자가결찰 브라켓군, Micro-arch군, Perpect Clear2이 순으로 정지, 운동 마찰력이 유의하게 높았다 ($p$ < 0.001). $0^{\circ}$$3^{\circ}$의 브라켓-호선 각도에서 같은 크기의 Ni-Ti 호선은 코팅 여부에 따른 정지, 운동 마찰력의 유의한 차이가 없었으나, $3^{\circ}$에서 자가결찰 브라켓군의 0.016" ${\times}$ 0.022" inch Ni-Ti 호선에서만 코팅된 경우에 마찰력이 유의하게 높았으며 ($p$ < 0.001), $6^{\circ}$$9^{\circ}$의 브라켓-호선 각도에서 원형과 각형 호선은 모두 같은 크기의 코팅된 호선에서 정지, 운동 마찰력이 유의하게 높았다 ($p$ < 0.001). 코팅된 호선은 크기가 커질수록 정지, 운동 마찰력이 유의하게 높아졌다 ($p$ < 0.001). 각형 호선은 원형 호선 보다 정지, 운동 마찰력이 유의하게 높았으나, $9^{\circ}$의 브라켓-호선 각도에서 0.016" inch coated Ni-Ti 호선만은 0.016" ${\times}$ 0.022" inch Ni-Ti 호선보다 마찰력이 높았다 ($p$ < 0.001). 브라켓-호선 각도가 증가함에 따라 정지, 운동 마찰력도 유의하게 높아졌으나 ($p$ < 0.001), Micro-arch군과 Perpect Clear2군에서 0.016 inch Ni-Ti 호선과 이루는 각도 $0^{\circ}$, $3^{\circ}$에서는 마찰력의 유의한 차이가 없었다.

Precise EPD Measurement of Single Crystal Sapphire Wafer

  • Lee, Yumin;Kim, Youngheon;Kim, Chang Soo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.223.1-223.1
    • /
    • 2013
  • Since sapphire single crystal is one of the materials that have excellent mechanical and optical properties, the single crystal is widely used in various fields, and the demand for the use of substrate of LED devices is increasing rapidly. However, crystal defects such as dislocations and stacking faults worsen the properties of the single crystal intensely. When sapphire wafer of single crystal is used as LED substrate, especially, crystal defects have a strong influence on the characteristics of a film deposited on the wafer. In such a case quantitative assessment of the defects is essential, and the evaluation technique is now becoming one of the most important factors in commercialization of sapphire wafer. Wet etching is comparatively easy and accurate method to estimate dislocation density of single crystal because etching reaction primarily takes place where dislocations reached crystal surface which are chemically weak points, and produces etch pit. In the present study, the formation behavior of etch pits and etching time dependence were studied systematically. Etch pit density(EPD) analysis using optical microscope was also conducted and measurement uncertainty of EPD was studied to confirm the reliability of the results. EPDs and measurement uncertainties for 4 inch sapphire wafers were analyzed in terms of 5 and 21 points EPD readings. EPDs and measurement uncertainties in terms of 5 points readings for 4 inch wafers were compared by 2 organizations. We found that the average EPD value in terms of 5 points readings for a 4 inch sapphire wafer may represent the EPD value of the wafer.

  • PDF

40Gb/s 백플레인 이더넷을 위한 DFE 수신등화기 (A Design of the DFE based Receiver Equalizer for 40 Gb/s Backplane Ethernet)

  • 양충열;김광준
    • 한국통신학회논문지
    • /
    • 제35권2B호
    • /
    • pp.197-209
    • /
    • 2010
  • 본 논문은 10 Gb/s $\times$ 4 레인으로 구성되는 40 인치 FR-4 백플레인 채널을 설계 및 분석하고, 이를 바탕으로 제안된 40 Gb/s 급 수신 적응 등화기 (Receive and Adaptive Equalizer), 고속 등화 알고리즘 설계 및 시뮬레이션 결과에 관하여 기술한다. 백플레인을 통과하는 40 Gb/s 고속 데이터 통신 채널을 위해 FFF를 사용하지 않는 DFE의 10Gb/s 4채널의 수신 등화기가 제안된다. 본 수신 & 등화기는 46 인치 백플레인 채널의 수신종단에서 등화를 수행하기 위한 IEEE Std P802.3ba 표준 기반 등화기 요구조건을 만족한다.

용출형 극세사와 저온 융착사를 이용한 인테리어 직물의 기계적 물성 개선 (Improvement of mechanical properties of interior fabric using soluble micro-fiber and low melting PET)

  • 권윤정;안영무
    • 패션비즈니스
    • /
    • 제13권1호
    • /
    • pp.82-90
    • /
    • 2009
  • This research was made to manufacture the fabric for interior uses by spinning a low melting mono 4 denier PET staple fiber with a soluble 1.4 denier fine PET fiber. The blended yarn has a thickness ranging from 10's to 14's, and the soluble PET fine fiber was dissolved to make a pore in the polymer. Thereby a snap property was decreased and a resilience property was improved to be suitable for a functional synthetic leather. In order to attain the optimum condition, a mechanical property according to fineness, and mixing ratio of low melting polymer, warp density, weft density and blending ratio, and a heat contraction ratio according to blending ratio were experimented. The warp density, 220 T/inch of fine denier PET and the weft density, 64 T/inch of thick denier PET were generated to 4/4 both twill weave fabric having constant tensile property and thickness.

임상에서 적용되는 목발과 이론적 적합성에 대한 비교 연구 (The Study of Compare to Clinical Applied versus Theoretical Fitness on Axillary Crutch)

  • 안덕현;김근조
    • 대한물리치료과학회지
    • /
    • 제3권4호
    • /
    • pp.113-120
    • /
    • 1996
  • The purpose of this study was to comparison clinical applied versus theoretical fitness on axillary crutch in human stance phase. Ideal crutch length is defined as the length of the crutch, including accessories, obtained during stance when the crutch tip is 15 cm(about 6inch) lateral and 15 cm(about 6 inch) anterior to the fifth toe and the axillary pad is 5 cm(about 2 inch) below the axillay fold. The participations(volunteers) were 71 inpatients(53 men and 18 women) who have orthopedic and neurological impairment on unilateral and/or bilateral lower extrimities, and mean age was 31.4 year old. Prior to participation, each subject informed the procedures of experiment from researcher and assistant researcher. This measured for axillary crutch using each of the following aspects : (1) length of actual using crutch, (2) length of axillary fold after modified(77% of actual height), (3) angle of elbow flexion after modified(77% of actual height). In order to determine the statistical significance of result, t-test were applied at the 0.05 level of significance. The result were as follows ; 1. There was significant difference between actual crutch and ideal crutch length(77% of actual height)(p<0.05). 2. There was significant difference of length of axillary fold between actual and ideal crutch (77% of actual height)(p<0.05). 3. There was significant difference of angle of elbow flexion between actual and ideal crutch(77% of actual height)(p<0.05).

  • PDF

SiC 기판상에 성장된 AlN 박막을 이용한 AlN 결정 성장에 관한 연구 (A study on the AlN crystal growth using its thin films grown on SiC substrate)

  • 인경필;강승민
    • 한국결정성장학회지
    • /
    • 제28권4호
    • /
    • pp.170-174
    • /
    • 2018
  • AlN 결정은 직경 1인치 크기의 기판이 개발되었고 계속 품질의 향상을 위해 연구되고 있다. 한편 2인치급 기판은 UV LED 칩 제조와 원가 감소를 위해 개발이 필요한 실정이다. 본 연구에서는 PVT 법으로 2인치의 AlN 결정을 SiC 기판상에 성장된 AlN 박막을 종자로 사용하여 성장의 가능성을 보고자 하였다. $10{\mu}m$ 두께의 AlN 박막 결정을 종자결정으로 사용하여 두께 7 mm의 AlN 결정을 성장하였다. 성장된 결정은 금속현미경과 실체현미경, DCXRD를 사용하여 분석하였다.