• Title/Summary/Keyword: 3D accuracy

Search Result 2,857, Processing Time 0.032 seconds

Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colors

  • Tan, Fa-Bing;Wang, Chao;Dai, Hong-Wei;Fan, Yu-Bo;Song, Jin-Lin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2018
  • PURPOSE. The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS. A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (${\alpha}=.05$). RESULTS. In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to $20.88{\mu}m$), of which the marginal and internal variations ranged $51.36-58.26{\mu}m$ and $18.33-20.04{\mu}m$, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than $5{\mu}m$, of which blue color group was the smallest ($3.27{\pm}0.24{\mu}m$) and white color group was the largest ($4.24{\pm}0.36{\mu}m$). These results were consistent with the DS data. CONCLUSION. The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.

Improvement of the Accuracy of Fringe Pattern Profilometry 3D Measurements through Phase Correction (위상 보정을 통한 Fringe Pattern Profilometry 3D 측정의 정확성 개선)

  • Kim, Ho-Joong;Cho, Tai-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.389-392
    • /
    • 2016
  • As technologies evolve, 3D measurement techniques using cameras have been developed continuously. In 3D measurement, high accuracy, fast speed, and easy implementation are very important factors. Recently, 3D measurement using multi-frequency fringes has been widely used. This method is generally a method of measuring the height of a image obtained by projecting a sine wave through the projector. The sine wave is produced by software. However, this sine wave is not a perfect sine wave by gamma of projector. This is given a bad influence on the height measurement, and can not measure the correct height. In this paper, we propose a method for correcting the phase of the sine wave to avoid being affected gamma. Through this method it will be able to make more accurate height measurement.

  • PDF

Construction and Application of 3D Image Model for GIS Spatial Analysis (GIS 공간분석을 위한 3D 영상모형의 구축과 활용)

  • Jung, Sung-Heuk;Lee, Kae-Dong;Lee, Jae-Kee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.6
    • /
    • pp.561-569
    • /
    • 2008
  • Currently, satellite image, aerial image and airborne laser scanning data are mostly used to build 3D image models. However, we are in need of quality 3D image models as current models cannot express topographic and features most elaborately and realistically. When making 3D image models, the model is first built and textures from terrestrial photos are applied to add realistic features to the model. This study analyzed techniques to use photogrammetry and laser scanning data to create a 3D image models with topography, building and statue that emphasize spatial accuracy, delicate depiction and photo-realistic imaging. 3D image models with spatial accuracy and photographic texture were built to be served via 3D image map services systems on the internet. The 3D image models can be used for various purposes, such as daylight and view right analysis, landscape analysis, facility management system.

Accuracy of orthodontic movements with 3D printed aligners: A prospective observational pilot study

  • Marco Migliorati;Sara Drago;Tommaso Castroflorio;Paolo Pesce;Giovanni Battista;Alessandra Campobasso;Giorgio Gastaldi;Filippo Forin Valvecchi;Anna De Mari
    • The korean journal of orthodontics
    • /
    • v.54 no.3
    • /
    • pp.160-170
    • /
    • 2024
  • Objective: Owing to the availability of 3D software, scanners, and printers, clinicians are encouraged to produce in-office aligners. Recently, a new direct-printing resin (Tera Harz TC-85DAC) has been introduced. Studies on its mechanical characteristics and biological effects have been published; however, evidence on its efficacy in orthodontic treatment remains scarce. This pilot study aimed to investigate the accuracy of teeth movement achieved with direct-printed aligners. Methods: Seventeen patients (eight males and nine females) with a mean age of 27.67 ± 8.95 years, presenting with dental rotations < 30° and spaces/crowding < 5 mm, were recruited for this study. The teeth movement was planned starting from a T0 digital dental cast. The 3D direct-printed aligners were produced using Tera Harz TC-85DAC resin. Once the orthodontic treatment was completed, a final digital cast was obtained (T1). The planned teeth positions were then superimposed onto the T0 and T1 digital models. The differences between the programmed movements and the achieved overall torque, tip, rotation, and transverse dimensions were assessed using the paired t test or Wilcoxon's signed rank test. Results: The overall accuracies for torque, tip, and rotation were 67.6%, 64.2%, and 72.0%, respectively. The accuracy of the change in transverse diameter was 99.6%. Conclusions: Within the limits of the present pilot study (difficulties with abnormally shaped teeth and use of attachments), it can be concluded that 3D printed aligners can be successfully printed in-house and utilized for mildly crowded cases, with a comparable accuracy of tooth movement to that of other aligners.

A Study on Terrain Construction of Unmanned Aerial Vehicle Simulator Based on Spatial Information (공간정보 기반의 무인비행체 시뮬레이터 지형 구축에 관한 연구)

  • Park, Sang Hyun;Hong, Gi Ho;Won, Jin Hee;Heo, Yong Seok
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.9
    • /
    • pp.1122-1131
    • /
    • 2019
  • This paper covers research on terrain construction for unmanned aerial vehicle simulators using spatial information that was distributed by public institutions. Aerial photography, DEM, vector maps and 3D model data were used in order to create a realistic terrain simulator. A data converting method was suggested while researching, so it was generated to automatically arrange and build city models (vWorld provided) and classification methods so that realistic images could be generated by 3D objects. For example: rivers, forests, roads, fields and so on, were arranged by aerial photographs, vector map (land cover map) and terrain construction based on the tile map used by DEM. In order to verify the terrain data of unmanned aircraft simulators produced by the proposed method, the location accuracy was verified by mounting onto Unreal Engine and checked location accuracy.

Four Anchor Sensor Nodes Based Localization Algorithm over Three-Dimensional Space

  • Seo, Hwajeong;Kim, Howon
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.4
    • /
    • pp.349-358
    • /
    • 2012
  • Over a wireless sensor network (WSN), accurate localization of sensor nodes is an important factor in enhancing the association between location information and sensory data. There are many research works on the development of a localization algorithm over three-dimensional (3D) space. Recently, the complexity-reduced 3D trilateration localization approach (COLA), simplifying the 3D computational overhead to 2D trilateration, was proposed. The method provides proper accuracy of location, but it has a high computational cost. Considering practical applications over resource constrained devices, it is necessary to strike a balance between accuracy and computational cost. In this paper, we present a novel 3D localization method based on the received signal strength indicator (RSSI) values of four anchor nodes, which are deployed in the initial setup process. This method provides accurate location estimation results with a reduced computational cost and a smaller number of anchor nodes.

A Study on Trip Distribution Estimation Model's Accuracy: Using Daegu City O-D Tables (통행분포 예측모형별 예측 정확도(精確度)에 관한 연구: 대구시 O-D표를 대상으로)

  • Ryu, Yeong-Geun;Woo, Yong Han
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.5
    • /
    • pp.43-59
    • /
    • 2012
  • It is generally assumed about trip distribution estimation model that growth factor model's estimation accuracy is higher than that of other models in short-term and that gravity model's estimation accuracy is higher than that of other models in long-term. For validation of such assumptions, this study compares estimation accuracies of each estimation model using 3year(1988, 1992, 2004) O-D tables from Daegu city. Each estimation model's accuracy were compared by mid-size and large-size zone as well as short-term and long-term target years. The results show that the trip distribution estimation model selection by usual assumption is not always right.

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

dLoran Measurement in Yeongil Bay using the Pohang Loran-C (9930M) (포항 로란-C(9930M) 이용 영일만 dLoran 측정)

  • Lee, Chang Bok;Lee, Jong Koo;Lee, Young Kyu;Hwang, Sang-Wook;Lee, Sang Jeong;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.38 no.3
    • /
    • pp.227-232
    • /
    • 2014
  • There are three essential components of eLoran: dLoran, data map of ASF, and the Loran data channel. Particularly, dLoran improves navigation accuracy, which is the core technology of eLoran systems. The requirement of HEA's absolute accuracy, less than 20 meters, can be satisfied via dLoran measurements and their corrections. In this study, dLoran measurements using the Pohang Loran-C (9930M) station signal were conducted at Yeongil Bay. We established a dLoran reference station at Homigot Management Office for navigation aids within the Bay. We estimated the effectiveness of the dLoran between the reference site (Homigot Management Office) and a test site (Heunghwan beach) by measuring TOAs. We verified that the TOA data measured at these two regions were highly correlated. The temporal differences in the data between the dLoran reference station and test site were about 10~30 ns per day, which is equivalent to a ranging error of 3~9 m. This result shows that eLoran can meet the requirement of 8~20 meters position accuracy for maritime HEA by correcting the ASF at the user's receiver.

Mapping 3D Shorelines Using KOMPSAT-2 Imagery and Airborne LiDAR Data (KOMPSAT-2 영상과 항공 LiDAR 자료를 이용한 3차원 해안선 매핑)

  • Choung, Yun Jae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • A shoreline mapping is essential for describing coastal areas, estimating coastal erosions and managing coastal properties. This study has planned to map the 3D shorelines with the airborne LiDAR(Light Detection and Ranging) data and the KOMPSAT-2 imagery, acquired in Uljin, Korea. Following to the study, the DSM(Digital Surface Model) is generated firstly with the given LiDAR data, while the NDWI(Normalized Difference Water Index) imagery is generated by the given KOMPSAT-2 imagery. The classification method is employed to generate water and land clusters from the NDWI imagery, as the 2D shorelines are selected from the boundaries between the two clusters. Lastly, the 3D shorelines are constructed by adding the elevation information obtained from the DSM into the generated 2D shorelines. As a result, the constructed 3D shorelines have had 0.90m horizontal accuracy and 0.10m vertical accuracy. This statistical results could be concluded in that the generated 3D shorelines shows the relatively high accuracy on classified water and land surfaces, but relatively low accuracies on unclassified water and land surfaces.