• 제목/요약/키워드: 3D Ultrasonic

검색결과 309건 처리시간 0.025초

PMN-PNN-PZT 세라믹스의 미세구조 및 압전 특성 (Microstructure and Piezoelectric Properties of PMN-PNN-PZT Ceramics)

  • 류주현;김승원
    • 한국전기전자재료학회논문지
    • /
    • 제30권8호
    • /
    • pp.496-500
    • /
    • 2017
  • $Pb(Mn_{1/3}Nb_{2/3})_{0.07}(Ni_{1/3}Nb_{2/3})_{0.10}(Zr_{0.5}Ti_{0.5})_{0.83}O_3$ composition ceramics with high piezoelectric properties were fabricated by the columbite precursor method for ultrasonic generators, and the effects of sintering temperature on microstructure and piezoelectric properties were systematically investigated. It was found that the tetragonality of the ceramics decreased with increase in sintering temperature. Moreover, excellent physical properties such as $d_{33}=447pC/N$, ${\varepsilon}_r=1,843$, $k_p=0.641$, and $Q_m=1,207$ were obtained for an ultrasonic generator when the second calcination temperature and sintering temperature were $720^{\circ}C$ and $920^{\circ}C$, respectively.

하소온도변화에 따른 초음파절삭기용 PMN-PNN-PZT 세라믹스의 압전 및 유전 특성 (Piezoelectric and Dielectric Properties of PMN-PNN-PZT Ceramics for Ultrasonic Generator with Calcination Temperature)

  • 류주현;김승원;서동희;이은섭;최낙구;정회승
    • 한국전기전자재료학회논문지
    • /
    • 제30권3호
    • /
    • pp.152-156
    • /
    • 2017
  • In this paper, $Pb(Mn_{1/3}Nb_{2/3})_{0.07}(Ni_{1/3}Nb_{2/3})_{0.10}(Zr_{0.5}Ti_{0.5})_{0.83}O_3$ ceramics were fabricated by the conventional solid state method to obtain excellent dielectric properties for ultrasonic generators. The effects of 2nd calcination temperature on their microstructure and piezoelectric properties were systematically investigated. The tetragonality increased in the ceramics when 2nd calcination temperature increased to the optimized temperature at $750^{\circ}C$. At that temperature, excellent physical properties ($d_{33}=352\;pC/N$, ${\varepsilon}_r=1,687$, $k_p=0.570$, $Q_m=1,640$) were obtained for ultrasonic generator application.

어군행동 원격감시 시스템의 개발에 관한 연구 ( 1 ) - 하드웨어와 소프트웨어 - ( Development of the Underwater Telemetry System to Monitor the Behavior of Fish ( 1 ) - Hardware and Software - )

  • 신형일
    • 수산해양기술연구
    • /
    • 제30권4호
    • /
    • pp.263-272
    • /
    • 1994
  • The hardware and the software of the prototype telemtry system to monitor the behavior of the fish are designed. This system consistes of five parts I. e. three omni-directional hydrophones, three ultrasonic receivers, a single board computer for the signal processing, two RF transceivers for the data communication, and a personnel computer. The sensitivty of the hydrophones is -170dB(re 1V/$\mu$Pa), the gain and the 3dB receiving bandwidth of the ultrasonic receivers are 115dB and 1500Hz respectively, and the sampling period is 33.3$\mu$sec in the signal processing part. The positioning error of the system using hyperbolic method is estimated to be less than 0.2m in case that the pinger locates inside of the baselines. The perfomance of the system considering a practical use was examined by numerical simulation and a water tank test of a pinger tracking experiment. In results, the system developed in prototype was confirmed that it could be useful for monitoring the behavior of fish in the limited water area.

  • PDF

초음파 조사시간에 따른 Microcystis aeruginosa의 성장억제 평가 (Evaluation of Growth Inhibition for Microcystis aeruginosa with Ultrasonic Irradiation Time)

  • 강은별;주진철;장소예;고현우;박정수;정무일;이동호
    • Ecology and Resilient Infrastructure
    • /
    • 제9권3호
    • /
    • pp.183-193
    • /
    • 2022
  • 초음파 (ultrasonic) 조사시간 (irradiation time)에 따른 Microcystis aeruginosa (M. aeruginosa)의 성장억제 (growth inhibition) 효과를 대용량 (10 L) 조류 시료를 활용해 다양한 초음파 조사시간 동안 (0.5, 1, 1.5, 2, 2.5, 3 hr) 실험실 규모 (lab-scale) 실험을 진행하였다. Chl-a와 M. aeruginosa 개체수 (cell number) 분석 결과, 초음파 조사 종료 이후 모든 실험군에서 Chl-a와 개체수가 감소되어 조류 성장억제가 관찰되었으며, 초음파 조사시간이 2시간 미만인 실험군 (T_B, T_C, T_D)은 저감 이후 조류의 급격한 재성장 (regrowth)이 관측되었으나, 조사시간이 2시간 이상인 실험군 (T_E, T_F, T_G)은 2시간 미만 조사한 실험군 대비 조류성장억제가 1 - 2일 더 지속되는 것을 확인하였다. 또한, 조류의 개체수가 초기 개체수까지 회복 시간 (recovery time)을 검토한 결과 조사시간 2시간을 기준으로 실험군 T_B (0.5 hr)는 7일, T_C (1 hr)와 T_D (1.5 hr)는 약 20일, T_E, T_F, T_G (≥ 2 hr)는 약 30일이 소요되어 초음파 조사 종료 후 초기 개체수까지의 회복 시간의 차이를 확인하였다. 비성장속도 (𝜇)와 일차분해속도(𝜅)를 도출한 결과, 실험군은 성장억제 기간 동안 초음파 조사시간과 비례하여 높은 일차분해율이 도출되었으며, 조사시간이 2시간 이상인 실험군의 재성장 시 비성장속도 (𝜇)는 2시간 미만인 실험군 대비 비성장속도 (𝜇)가 상대적으로 낮은 것으로 확인되었다. 따라서 정체수역 내 장기적인 (30일) 조류 성장억제를 위해서는 최소한 2시간 이상의 초음파 조사가 필요한 것으로 판단되나, 조류 성장억제를 위한 적정 초음파 조사시간은 정체수역의 규모, 수심, 흐름속도, 조류 농도 등의 다양한 현장조건에 따라 결정돼야 하며, 실제 적용 가능성을 높이기 위한 추가 연구가 필요한 것으로 판단된다. 초음파의 영향으로 인한 M. aeruginosa의 세포 표면 및 내부형질 변화를 관찰한 결과, 조류 세포 표면 및 세포막의 손상이 명확히 관측되었으며, 대조군 대비 실험군의 M. aeruginosa의 기낭 파괴 및 교란이 확인되었다.

위상측정방식을 이용한 3차원 초음파 풍향풍속계의 특성분석 (Characterization of three-dimensional ultrasonic anemometer using phase measurement)

  • 박도현;예윤해
    • 센서학회지
    • /
    • 제15권6호
    • /
    • pp.442-448
    • /
    • 2006
  • Ultrasonic anemometers using pulse envelope detection-based method are standard instruments in most meteorological studies. In this paper, a new phase measurement method is tried to achieve the enhanced resolution without changing dimensions. The measurement sensitivity, dynamic range, and measurement speed of the new instrument are 0.2 mm/s, 13.3 m/s, and 13 measurements/sec, respectively. A graphic user interface is added to show the velocity and direction of the wind with the speed of sound and temperature of the wind in the 3 dimensional space. The new anemometer could be useful for the measurement of the air speed, the flow of fluids, and even air flow inside the downtown buildings.

폴리에틸렌 배관의 전기융착부 비파괴검사기술에 관한 연구 (Study for Non-Destructive Testing of Polyethylene Electrofusion Joints - Ultrasonic Imaging test)

  • 길성희;권정락
    • 한국가스학회지
    • /
    • 제8권3호
    • /
    • pp.31-36
    • /
    • 2004
  • 본 연구에서는 PE배관 연결망에 있어 취약 부위인 두 개의 배관이 연결되는 부분 즉, 전기응착부에 대한 검사방법을 살펴보고 그 중에서도 위상배열 초음파를 이용한 비파괴 탐상방법에 대하여 고찰하였다. 그리고 정상 및 비정상 전기응착 시험편을 설계 및 제작하여 위상배열 초음파를 이용하여 PE배관 전기응착부에 대한 비파괴 탐상을 실시하였다. 마지막으로 현장에서 발생하는 전기융착 접합 실태를 조사한 후 원인을 분석하고 결함 유형을 분류하였다. 즉 융합 불량, 모래 섞임, 기포, 삽입 불량, 용입 과다의 5가지로 분류를 하였다.

  • PDF

3D Object Recognition Using SOFM (3D Object Recognition Using SOFM)

  • 조현철;손호웅
    • 지구물리
    • /
    • 제9권2호
    • /
    • pp.99-103
    • /
    • 2006
  • 3D object recognition independent of translation and rotation using an ultrasonic sensor array, invariant moment vectors and SOFM(Self Organizing Feature Map) neural networks is presented. Using invariant moment vectors of the acquired 16×8 pixel data of square, rectangular, cylindric and regular triangular blocks, 3D objects could be classified by SOFM neural networks. Invariant moment vectors are constant independent of translation and rotation. The recognition rates for the training and testing data were 95.91% and 92.13%, respectively.

  • PDF

압전세라믹/고분자 복합압전체 초음파 트랜스듀서를 이용한 3차원 수중 물체 복원 (3D Underwater Object Restoration Using Ultrasonic Transducer Fabricated with Piezoelectric Ceramics/polymer Composites)

  • 조현철;이기성;이수호;박정학;최헌일;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1537-1539
    • /
    • 1998
  • In this study, 3-D underwater object restoration using ultrasonic transducer fabricated with PZT-Polymer 1-3 type composite are presented. Using the acquired underwater object data 16${\times}$16 pixels. Modified SCL neural networks using the 16${\times}$16 low resolution image was used for underwater object restoration of 32${\times}$32 high resolution Image.

  • PDF

Transmission of ultrasonic guided wave for damage detection in welded steel plate structures

  • Liu, Xinpei;Uy, Brian;Mukherjee, Abhijit
    • Steel and Composite Structures
    • /
    • 제33권3호
    • /
    • pp.445-461
    • /
    • 2019
  • The ultrasonic guided wave-based technique has become one of the most promising methods in non-destructive evaluation and structural health monitoring, because of its advantages of large area inspection, evaluating inaccessible areas on the structure and high sensitivity to small damage. To further advance the development of damage detection technologies using ultrasonic guided waves for the inspection of welded components in structures, the transmission characteristics of the ultrasonic guided waves propagating through welded joints with various types of defects or damage in steel plates are studied and presented in this paper. A three-dimensional (3D) finite element (FE) model considering the different material properties of the mild steel, high strength steel and austenitic stainless steel plates and their corresponding welded joints as well as the interaction condition of the steel plate and welded joint, is developed. The FE model is validated against analytical solutions and experimental results reported in the literature and is demonstrated to be capable of providing a reliable prediction on the features of ultrasonic guided wave propagating through steel plates with welded joints and interacting with defects. Mode conversion and scattering analysis of guided waves transmitted through the different types of weld defects in steel plates are performed by using the validated FE model. Parametric studies are undertaken to elucidate the effects of several basic parameters for various types of weld defects on the transmission performance of guided waves. The findings of this research can provide a better understanding of the transmission behaviour of ultrasonic guided waves propagating through welded joints with defects. The method could be used for improving the performance of guided wave damage detection methods.