• Title/Summary/Keyword: 3D 측정

Search Result 6,578, Processing Time 0.039 seconds

CMOS Based D-Band Push-Push Voltage Controlled Oscillator (푸쉬-푸쉬 방식을 이용한 CMOS 기반 D-밴드 전압 제어 발진기)

  • Jung, Seungyoon;Yun, Jongwon;Kim, Namhyung;Rieh, Jae-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1236-1242
    • /
    • 2014
  • In this work, a D-band VCO(Voltage Controlled Oscillator) has been developed in a 65-nm CMOS technology. The circuit was designed based on push-push mechanism. The output oscillation frequency of the fabricated VCO varied from 152.7 GHz to 165.8 GHz, and the measured output power was from -17.3 dBm to -8.7 dBm. A phase noise of -90.9 dBc/Hz is achieved at 10 MHz offset. The chip size of the circuit is $470{\mu}m{\times}360{\mu}m$ including the probing pads.

A Study on the 3-D Deformation Analysis for Safety Diagnosis of Bridges (교량의 안전진단을 위한 3차원 변형해석에 관한 연구)

  • 강준묵;윤희천;배상호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.1
    • /
    • pp.69-76
    • /
    • 1995
  • This study is the 3-D precision deformation measurement of a bridge, obtain results of precision control points by GPS and 3-D measurement system and develope efficientlty technices which can solve precision 3-D analysis by CRP In the result, we could overcome the problems of former control point measurement in the way of the combination system of GPS and 3-D measurement system to positioning decision of reference points and control points. Then we could symplify old measurement process on the 3-D deformation analysis of a linear structure and complement parted analysis fault of measurement instrument.

  • PDF

Develipment of a hand motion analysis system using a 3-D Glove (3-D Glove를 이용한 손동작의 분석 시스템 개발)

  • 윤명환;권오채;한수미;박재희;이경태
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.393-397
    • /
    • 1997
  • 본 연구에서는 손동작(Hand Motion)과 수작업(Manual Task) 분석에 VR환경에서 사용되는 각도 측정 장갑(3-D Glove)을 이용하는 방법을 제안하였다. 본 연구에서 개발된 손동작(Hand Motion)과 수작업(Manual Task)의 분석 시스템은 18-sensor $Cyberglove^{TM}$정 시스템으로부터 측정된 angle data를 기초로 손동작이나 수작업에 대한 totalmuscle moment값과 total muscle excursion값을 구하고, digit와 joint의 moment값을 X,Y.Z방향별고 구하는 기능을 가지고 있다. 시스템의 구성은 : (1) $Cyberglove^{TM}$ System과 분석 시스템의 digital data 처리를 기반으로 하는 손동작의 측정 시스템 ; (2) $Cyberglove^{TM}$ System에서 얻어진 자료를 바탕으로 3차원 공간에서 손동작을 표현할 수 있는 Kinematic Hand Model ; (3) Hand Model과 $Cyberglove^{TM}$ Systme을 기반으로 3차원에서 손동작의 역학적 분석을 할 수 있는 3-D Hand Biomechanical Model ; 등으로 되어있다. 본 시스템은 Telerobotics, Medicine, Virtual Reality 등 다양한 분야에 응용이 가능하며, 수작업에 관련되는 Product Design, Manual Control Device, Computer I/O Device의 설계에도 도움이 될 것으로 기대된다.

  • PDF

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry- (3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교-)

  • Paek, Kyung-Ja;Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

Study on Appropriateness of a Remote Facility for Discharge Measurement in Small Stream by 3-Dimensional Flow Analysis (3차원 흐름해석을 통한 소하천 원격유량측정시설의 적정성 연구)

  • Kim, Jong-Chan;Hong, Kee-Hoon;Ko, Jae-Min;Kim, Chin-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.457-461
    • /
    • 2010
  • 소하천에서의 효율적인 유량측정 수행을 위해서 K-water(한국수자원공사) 충청지역본부에서는 금강유역의 보청천 지류인 곰쟁이천에 원격유량측정시설 개념의 위어(weir)를 이용한 고정단면 시설물을 2006년도에 설치하였으며, 2007년부터 2009년까지 시설물 직하류에서 도섭을 통한 유량측정을 실시하였고 3차원 흐름해석 결과와의 비교를 통해 소하천 원격유량측정시설의 적정성을 분석하였다. 총 55회의 유량측정 성과를 이용하여 수위-유량 관계곡선식을 산정하였으며, FLOW-3D를 이용하여 3차원 흐름해석을 실시하였다. Francis 유량산정 공식인 Q=$1.84bH^{3/2}$을 통해 계산되는 수위별 유량, 유량측정 성과에 의한 수위-유량 관계곡선식, 그리고 FLOW-3D로부터 계산된 수위별 유량을 비교하였으며, 실측유량과 계산된 유량의 차이를 비교 검토하였다. 이러한 비교 검토를 통해 소유량 구간에 대해서는 원격유량측정시설의 적정성을 확인할 수 있었으며, 갈수시 미소유량이 흐르는 소하천에 위치한 지점에 대해서는 인력 및 비용이 많이 소요되는 도섭을 통한 직접 유량측정 수행보다는 검증된 유량측정시설(위어, 파샬플룸 등)을 통한 유량측정이 더욱 효과적인 것으로 판단되었다.

  • PDF

Angular-based Measurement for Quantitative assay of Albumin in three-dimensional Paper-based analytical Device (회전각도를 이용한 알부민 농도 측정용 3차원 종이 칩)

  • Kim, Dong-Ho;Jeong, Seong-Geun;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.286-292
    • /
    • 2020
  • This study presents an angular-based measurement on three-dimensional paper-based analytical devices (3D-PADs) for quantitative detection of albumin without using an image analyzer. We demonstrate a simple quantitative and straightforward approach based on the angle of the discolored area as detection criteria. 3D-PADs are rapidly fabricated by the wax-printing and laminating process. The 3D-PADs are treated with citrate buffer and tetrabromophenol blue to react with albumin in a sample solution. Dropping sample solution into sample pad in the 3D-PAD, fluid flows toward the assay zone laterally and vertically by capillary action. We find that the change of angle of the discolored area correctly reflects the concentration of albumin and is reliable determinant for the measurement of the albumin concentration. It is the first demonstration of angular-based detection as a simple, inexpensive, and equipment-free approach for point-of-care diagnosis.

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

석영의 파동소광을 이용한 포천-기산리 일대의 화강암 변형의 정량화

  • 정원석;윤현수;나기창
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2003.05a
    • /
    • pp.80-80
    • /
    • 2003
  • 포천-기산리 일대에 분포하는 쥬라기의 대보화강암류의 변형정도를 결정하기 위해 석영의 파동소광의 강도(IWE : Intensity of Wavy Extinction)를 편광현미경, 디지털 카메라, NIH Image로 측정하였다. 파동소광이 나타나는 석영입자의 한 부분이 편광현미경 상에서 최대 소광이 될 때 IWE를 측정하고, 이 때 나타나는 파동소광의 아입자경계에 수직한 방향으로 측정을 시도하였다 본 연구에 사용된 NIH Image는 파동소광을 보여주는 각 부분의 광도를 256단계의 흑백 농담변화로 나타낼 수 있다. 이를 이용하여 측정 길이에 대한 농담변화로 IWE를 구하였다. 이렇게 획득한 IWE를 5$^{\circ}$ 단위로 묶어 돗수분포표로 처리하였으며, 자료의 분포특성상 히스토그램의 최빈값과 중간값 사이의 중간값을 그 암석의 대표 IWE로 정의하였다. 이를 다시 5단계의 변형대(무변형, 저변형, 중변형, 고변형, 최고변형)와 각각의 변형지수(D1, D2, D3, D4, D5)로 묶었다. 본 연구지역에 분포하는 화강암류는 흑운모화강암(Gb), 동부의 석류석흑운모화강암(Ggb) 그리고 북부의 복운모화강암(Gtm)으로 구성되어 있는 바 본 연구에는 크게 포천읍을 기준으로 서부에 분포하는 Gb와 동부에 분포하는 Ggb에서 파동소광의 강도 측정이 이루어 졌다. 연구결과 Gb는 D2 이하의 낮은 변형도가 나타났고, Ggb는 D3이상의 고변형이 나타나, 전반적으로 조사지역의 북서부에서 남동부로 갈수록 변형도가 증가하는 양상을 보여주었다.

  • PDF

3D measuring system by using the stereo vision (스테레오비젼을 이용한 3차원 물체 측정 시스템)

  • 조진연;김기범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.224-228
    • /
    • 1997
  • Computer vision system become more important as the researches on inspection systems, intelligent robots , diagnostic medical systems is performed actively. In this paper, 3D measuring system is developed by using stereo vision. The relation between left image and right image is obtained by using 8 point algorithm, and fundamental matrix, epipole and 3D reconstruction algorithm are used to measure 3D dimensions. 3D measuring system was developed by Visual Basic, in which 3D coordinates would be obtained by simple mouse clicks. This software would be applied to construction area, home interior system, rapid measuring system.

  • PDF