• Title/Summary/Keyword: 316 Stainless Steel

Search Result 458, Processing Time 0.027 seconds

Low-cycle fatigue behaviors of 316L austenitic stainless steel in high temperature water: Effects of pre-soaking, dissolved oxygen, and boric acid & lithium hydroxide

  • Xiong, Yida;Watanabe, Yutaka;Shibayama, Yuki;Zhong, Xiangyu;Mary, Nicolas
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3215-3224
    • /
    • 2022
  • Latest studies found that for 316LN austenitic stainless steel (ASS), its LCF life decreased noticeably in high temperature water containing a great amount of dissolved oxygen (DO) (2 ppm DO), compared with that in the water containing 50 or 100 ppb DO. This finding is different from previous studies about ASSs. This study confirmed that the 316L had similar behavior to 316LN. The LCF life of 316L in water containing 1000 ppb DO water was considerably shorter than that in the water containing 50 ppb DO. Addition of boric acid & lithium hydroxide and pre-soaking did not display noticeable effects on the LCF life of this material in the water with 1000 ppb DO, indicating the discrepancy between the latest studies and previous studies was not caused by the boric acid & lithium hydroxide and pre-soaking. This study also confirmed that similar to 316LN, when a certain amount of DO was added into the water, the amount of hydrogen absorbed into the material decreased significantly compared with that when the DO was less than 5 ppb.

The Influence of Temperature on Low Cycle Fatigue Behavior of Prior Cold Worked 316L Stainless Steel (II) - Life Prediction and Failure Mechanism - (냉간 가공된 316L 스테인리스 강의 저주기 피로 거동에 미치는 온도의 영향 (II) - 수명예측 및 파손 기구 -)

  • Hong, Seong-Gu;Yoon, Sam-Son;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1676-1685
    • /
    • 2003
  • Tensile and low cycle fatigue tests on prior cold worked 3l6L stainless steel were carried out at various temperatures ftom room temperature to 650$^{\circ}C$. Fatigue resistance was decreased with increasing temperature and decreasing strain rate. Cyclic plastic deformation, creep, oxidation and interactions with each other are thought to be responsible for the reduction in fatigue resistance. Currently favored life prediction models were examined and it was found that it is important to select a proper life prediction parameter since stress-strain relation strongly depends on temperature. A phenomenological life prediction model was proposed to account for the influence of temperature on fatigue life and assessed by comparing with experimental result. LCF failure mechanism was investigated by observing fracture surfaces of LCF failed specimens with SEM.

Characteristics of Boronized 316L Austenitic Stainless Steel by Powder Boronizing (분말붕소법을 이용한 오스테나이트계 스테인리스 316L강의 기계적 특성 향상을 위한 연구)

  • Cha, Byung-Chul;Bang, Hyun-Bae;Jo, Hyung-Ho;Jung, Uoo-Chang
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.2
    • /
    • pp.55-59
    • /
    • 2011
  • In this study, the mechanical properties of boronized 316L austenitic stainless steel have been investigated. Boronizing was carried out in solid medium consisting of Ekabor powder at $900^{\circ}C$ and $1000^{\circ}C$ for 2, 4 and 8 hours, respectively. The properties of sample were analyzed by field emission scanning electron microscope, X-ray diffractometer, Glow discharge spectrometer, micro-hardness tester and ball-on-disk wear tester. Increasing the boronizing time and temperature, the hardness of boronized samples were shown over Hv 2000 and the thickness of boride layers were also increased linearly. XRD patterns of samples were revealed the presence of borides such as FeB, $Fe_2B$, CrB, $Cr_2B$ and $Ni_3B$. Friction coefficient of boronized STS 316L was shown the low value at $900^{\circ}C$ for 8 hours and $1000^{\circ}C$ for 4 hours, respectively.

Deposition Characteristics and Mechanical Properties of Stainless Steel 316L Fabricated via Directed Energy Deposition (에너지 제어 용착을 이용한 스테인리스 316L의 적층 특성 및 기계적 물성 평가)

  • Yang, Seung-weon;Lee, Hyub;Shim, Do-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.59-69
    • /
    • 2021
  • Directed energy deposition (DED) is an additive manufacturing technology involving a focused high-power laser or electron beam propagating over the substrate, resulting in melt pool formation while simultaneously supplying metal powder to the melt pool area to deposit the material. DED is performed to repair and strengthen parts in various applications, as it can be easily integrate local area cladding and cross-material deposition. In this study, we characterize stainless steel 316 L parts fabricated via DED based on various deposition conditions and geometries to widen the application of DED. The deposition characteristics are investigated by varying the laser power and powder feed rate. Multilayer deposition with a laser power of 362 W and a powder feed rate of 6.61 g/min indicate a height closest to the design value while affording high surface quality. The microhardness of the specimen increases from the top to the bottom of the deposited area. Tensile tests of specimens with two different deposition directions indicate that horizontally long specimens with respect to a substrate demonstrate a higher ultimate tensile strength and yield strength than vertically long specimens with lower elongation.

Corrosion Characteristics of 316L Stainless Steel with Chloride Concentrations in Cathode Operating Conditions of Metallic Bipolar Plate for PEMFC (고분자 전해질 연료전지 금속분리판용 316L 스테인리스강의 양극작동조건에서 염화물 농도에 따른 부식 특성)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.435-450
    • /
    • 2021
  • The interest in eco-friendly energy is increasing, and polymer electrolyte membrane fuel cell (PEMFC) is attracting attention as alternative power sources. Research on metallic bipolar plates, a fuel cell component, is being actively conducted. However, since the operating conditions of PEMFC, in which sulfuric acid (H2SO4) and hydrofluoric acid (HF) are mixed, are strong acidity, the durability of the metallic bipolar plate is very important. In this research, the electrochemical characteristics and corrosion damage behavior of 316L stainless steel, a material for metallic bipolar plates, were analyzed through potentiostatic corrosion tests with test times and chloride concentrations. As the test times and chloride concentrations increased, the current density and corrosion damage increased. As a result of observation with scanning electron microscope(SEM) and 3D microscope, both the depth and width of pitting corrosion increased with increases in test times and chloride concentrations. In particular, the pitting corrosion damage depth at test conditions of 6 hours and 1000 ppm chloride increased the most. The growth of the pitting corrosion damage was not directly proportional to time and increased significantly after a certain period.

Corrosion characteristics and interfacial contact resistances of TiN and CrN coatings deposited by PVD on 316L stainless steel for polymer electrolyte membrane fuel cell bipolar plates

  • Lee, Jae-Bong;Oh, In Hwan
    • Corrosion Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.171-178
    • /
    • 2013
  • In a polymer membrane fuel cell stack, the bipolar plate is a key element because it accounts for over 50% of total costs of the stack. In order to lower the cost of bipolar plates, 316L stainless steels coated with nitrides such as TiN and CrN by physical vapor deposition were investigated as alternative materials for the replacement of traditional brittle graphite bipolar-plates. For this purpose, interfacial contact resistances were measured and electrochemical corrosion tests were conducted. The results showed that although both TiN and CrN coatings decreased the interfacial contact resistances to less than $10m{\Omega}{\cdot}cm^2$, they did not significantly improve the corrosion resistance in simulated polymer electrolyte membrane fuel cell environments. A CrN coating on 316L stainless steel showed better corrosion resistance than a TiN coating did, indicating the possibility of using modified CrN coated metallic bipolar plates to replace graphite bipolar plates.

A Fundamental Study on Properties of Mortar Using the Stainless Steel Slag as Admixture (스테인레스 스틸 슬래그 미분말을 사용한 모르터의 물성에 관한 기초적 연구)

  • 이희두;강경수;임남기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.311-316
    • /
    • 2002
  • The following results are achieved from a mortar flow test depending on stainless steel slag fineness, rate of replacement, and a research on material age compressive strength, strength activity index. 1. Flow is proportional to the stainless steel slag fineness. 2. Mixing stainless steel slag decreases compressive strength 3. Material age compressive strength has the maximum value when stainless steel slag fineness is 6000$cm^2$/g. 4. Material age 7day strength activity index satisfies KSCE 95-01 at all conditions except the case of fineness 8000$cm^2$/gㆍstainless steel slag rate of replacement 30%. 5. Material age 28day strength activity index satisfies KSCE 95-01 in case of stainless steel slag fineness 4000$cm^2$/gㆍrate of replacement 10%, fineness 6000$cm^2$/gㆍ10%, or 20%.

  • PDF

Effects of Ar gas composition on the surface properties of AISI316L stainless steel during low temperature plasma nitriding after low temperature plasma carburizing (AISI316L stainless steel에 저온 프라즈마 침탄처리 후 질화처리 시 Ar 가스조성이 표면특성에 미치는 영향)

  • Jeong, Gwang-Ho;Lee, In-Seop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.159-160
    • /
    • 2007
  • 저온 플라즈마 침탄 처리 후 연속적인 공정으로 저온 플라즈마 질화를 실시하여 내식성과 표면경도를 향상시키는 처리에서 질화처리 시 Ar 가스가 표면특성에 미치는 영향을 조사 하였다. 모든 시편의 경도가 미처리재 보다 약4배 증가하였으며, Ar가스의 양이 증가할수록 N의 침투깊이가 깊어졌다. 전체 경화증의 두께는 거의 일정하였고, 경화층은 모재보다 내식성이 증가되어 단면조직사진에서 밝게 나타났다.

  • PDF

A Study on the Ceramic Coating of Biopsy Needle (조직생검용 Needle의 세라믹 코팅에 관한 연구)

  • Cho, Sung-Man;Chung, Hyup-Jae;Kim, Man-Tae;Rhee, Kyong-Yop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.121-126
    • /
    • 2009
  • Stainless steel 316L (STS 316L) is widely used as a material of biopsy needle. However it has a side effect that tissue can be damaged by electrochemical operation between tissue and STS 316L. Many studies have been made on the ceramic coating of biopsy needle to reduce the side effect. In this study, STS 316L was coated with three bioceramics, $Al_2O_3$, $SiO_2$ and $ZrO_2$ using a RF magnetron sputtering method. The effects of ceramic coating on the electrical conductivity and coating strength of ceramic-coated STS 316L were investigated. The results showed that the electrical conductivity of ceramic-coated STS 316L was much lower than that of uncoated STS 316L. The coating strength of $ZrO_2$-coated STS 316L was 30% and 70% higher, respectively than those of $Al_2O_3$-coated STS 316L and $SiO_2_3$-coated STS 316L.

Pitting Corrosion Behavuor of N2+ ion Implanted AISI 316L Stainless Steel Compacts (질소 이온주입된 AiSi 316L 스테인리스강 소결체의 공식거동)

  • 최한철
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.2
    • /
    • pp.73-80
    • /
    • 1998
  • The aim of this study is to develop sintered stainless steels (SSS) with good mechanical strength, wear resistance, and corrosion resistance by nitrogen ion implantation on the Culated SSS surface. Stainless steel compacts containg Cu (2-10 wt%) were prepared by electroless Cu-pating method which results in the increased3 homogenization in alloying powder. Nitrogen ion implantation was carried out by using N2 gas as the ion source. Nitrogen ions were embedded by an acceleratol of 130keV with doese $3.0\times10^{17}\;ions/\textrm{cm}^2$ on the SSS at $25^{\circ}C$ in$2\times10^{-6}$ torr vacuum. The nitrogen ion implanted SSS obtained from anodic ploarization curves revealed higher corrosion potential than that of nitrogen ion unimplante one. And nitrogen ion implanted 316LSSS had good resistance to pitting corrosion due to the synergistic effect of Mo and N, and the inhibition of $NH_4\;^+$<\TEX>, against $CI^-$<\TEX>.

  • PDF