• Title/Summary/Keyword: 3-layer thin film

Search Result 1,312, Processing Time 0.033 seconds

Electrostatically-Driven Polysilicon Probe Array with High-Aspect-Ratio Tip for an Application to Probe-Based Data Storage (초소형 고밀도 정보저장장치를 위한 고종횡비의 팁을 갖는 정전 구동형 폴리 실리콘 프로브 어레이 개발)

  • Jeon Jong-Up;Lee Chang-Soo;Choi Jae-Joon;Min Dong-Ki;Jeon Dong-Ryeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.166-173
    • /
    • 2006
  • In this study, a probe array has been developed for use in a data storage device that is based on scanning probe microscope (SPM) and MEMS technology. When recording data bits by poling the PZT thin layer and reading them by sensing its piezoresponse, commercial probes of which the tip heights are typically shorter than $3{\mu}m$ raise a problem due to the electrostatic forces occurring between the probe body and the bottom electrode of a medium. In order to reduce this undesirable effect, a poly-silicon probe with a high aspect-ratio tip was fabricated using a molding technique. Poly-silicon probes fabricated by the molding technique have several features. The tip can be protected during the subsequent fabrication processes and have a high aspect ratio. The tip radius can be as small as 15 nm because sharpening oxidation process is allowed. To drive the probe, electrostatic actuation mechanism was employed since the fabrication process and driving/sensing circuit is very simple. The natural frequency and DC sensitivity of a fabricated probe were measured to be 18.75 kHz and 16.7 nm/V, respectively. The step response characteristic was investigated as well. Overshoot behavior in the probe movement was hardly observed because of large squeeze film air damping forces. Therefore, the probe fabricated in this study is considered to be very useful in probe-based data storages since it can stably approach toward the medium and be more robust against external shock.

Characterization of ZnO:Al layer with post-annealing and HCl etching (후열처리에 따른 ZnO:Al 투명전도막 특성 변화 및 HCl 식각 특성 분석)

  • Kim, Han-Ung;Kim, Young-Jin;Cho, Jun-Sik;Park, Sang-Hyun;Yoon, Kyung-Hoon;Song, Jin-Soo;O, Byung-Sung;Lee, Jeong-Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.159-159
    • /
    • 2009
  • RF 스퍼터링법을 이용하여 유리기판위에 ZnO:Al 박막을 증착하고 다양한 조건 하에서 후 열처리를 실시하여 이에 따른 박막의 구조적, 전기적 및 광학적 특성과 HCl 습식 식각 후의 표면형상 변화를 조사하였다. ZnO:Al 투명전도막은 우수한 전기적, 광학적 특성, 수소 플라즈마 안정성 및 저 비용 등으로 실리콘 박막 태양전지 전면 전극용으로 많은 관심을 받고 있다. 기존의 비정질 실리콘 박막 태양전지용으로 많이 사용되고 있는 상용 Asahi-U형 ($SnO_2:F$) 투명전도막의 경우는 수소 플라즈마에 대한 안정성이 낮고 입사광의 장파장 대역에서의 낮은 산란특성으로 인하여 실리콘 박막 태양전지의 고효율화를 위한 적용에 한계를 나타내고 있다. 이를 개선하기 위하여 스퍼터링법으로 우수한 전기적 특성을 갖는 ZnO:Al 박막을 제조한 후 습식 식각을 통한 표면형상 변화를 통하여 입사광의 산란특성을 향상시키는 방법이 개발되어 많은 연구가 이루어지고 있다. 본 연구에서는 2.5 wt%의 $Al_2O_3$가 함유된 ZnO 타겟을 이용하여 ZnO:Al 박막을 RF 스퍼터링으로 증착한 후 $N_2$ 분위기와 진공 분위기 하에서 다양한 시간과 온도에 따라 후열처리를 하여 열처리 전 박막과의 물질 특성을 상호 비교하고 1%로 희석된 HCl로 습식 식각하여 열처리 전 박막의 구조적 특성이 습식 식각 후의 박막 표면형상 변화에 미치는 영향을 조사하였다. 이로부터 후열처리를 통한 ZnO:Al 투명전도막의 특성을 최적화하고 Asahi-U형 투명전도막과의 특성 비교를 통하여 실리콘 박막 태양전지용 전면전극으로의 적용 가능성을 조사하였다.

  • PDF

In vivo and In vitro Metabolism of Recombinant Human Epidermal Growth Factor (DWP401) in Rats (재조합 인간 상피세포성장인자(DWP401)의 흰쥐에서의 in vivo와 in vitro 대사)

  • Koh, Yeo-Wook;Nam, Kouen-Ho;Jung, Ju-Young;Park, Seung-Kook;Yu, Young-Hyo;Kim, Jae-Hwan;Han, Kun;Park, Myung-Hwan;Shim, Chang-Koo
    • YAKHAK HOEJI
    • /
    • v.41 no.3
    • /
    • pp.381-388
    • /
    • 1997
  • Metabolism of DWP401, recombinant juman epidermal growth factor, was examined in vivo and in vitro in rats. When $^{125}I$-labeled DWP401 was administered at a dose of 50 ${\mu}g$/kg by i.v. injection. $^{125}I$-labeled DWP401 was rapidly degraded within 30 minytes above 93%. Thin layer chromatography analysis of urine collected for 24 hr after i.v. administration of $^{125}I$-labeled DWP401 showed ohly one spot on a X-ray film which was considered as diiodo-tyrosine. This result suggests tha $^{125}I$-labeled DWP401 was completely digested into free amino acids without any specific intermediate polypeptides. About 42.1% of the administered iodine was recovered in 24 hr. For in vitro degradation study, $^{125}I$-labeled DWP401 was added to plama and tissue homogenates of rats and incubated at $37^{\circ}C$. Almost 98% of the added radioactivity recovered from the protein fraction of the liver, kidey, small intestine, stomach and spleen decreased rapidly. For examplem the recovery rates of $^{125}I$-labeled DWP401 were 58.6, 63.2, 39.9, 52.9 and 66.8% after 4hrs of incubation in respective organ homogenates.

  • PDF

Fabrication of Tungsten Nano Dot by Using Block Copolymer Thin Film (블록 공중합체 박막을 이용한 텅스텐 나노점의 형성)

  • Kang, Gil-Bum;Kim, Seong-Il;Kim, Yeung-Hwan;Park, Min-Chul;Kim, Yong-Tae;Lee, Chang-Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.13-17
    • /
    • 2006
  • Dense and periodic arrays of holes and tungsten none dots were fabricated on silicon oxide and silicon. The holes were approximately 25 nm wide, 40 nm deep, and 60 nm apart. To obtain nano-size patterns, self-assembling resists were used to produce layer of hexagonally ordered parallel cylinders of polymethylmethacrylate(PMMA) in polystyrene(PS) matrix. The PMMA cylinders were degraded and removed with acetic acid rinse to produce a PS mask for pattern transfer. The silicon oxide was removed by fluorine-based reactive ion etching(RIE). Selectively deposited tungsten nano dots were formed inside nano-sized trench by using a low pressure chemical vapor deposition(LPCVD) method. Tungsten nano dot and trenched silicon sizes were 26 nm and 30 nm, respectively.

  • PDF

MEMS-Based Micro Sensor Detecting the Nitrogen Oxide Gases (산화질소 검출용 마이크로 가스센서 제조공정)

  • Kim, Jung-Sik;Yoon, Jin-Ho;Kim, Bum-Joon
    • Korean Journal of Materials Research
    • /
    • v.23 no.6
    • /
    • pp.299-303
    • /
    • 2013
  • In this study, a micro gas sensor for $NO_x$ was fabricated using a microelectromechanical system (MEMS) technology and sol-gel process. The membrane and micro heater of the sensor platform were fabricated by a standard MEMS and CMOS technology with minor changes. The sensing electrode and micro heater were designed to have a co-planar structure with a Pt thin film layer. The size of the gas sensor device was about $2mm{\times}2mm$. Indium oxide as a sensing material for the $NO_x$ gas was synthesized by a sol-gel process. The particle size of synthesized $In_2O_3$ was identified as about 50 nm by field emission scanning electron microscopy (FE-SEM). The maximum gas sensitivity of indium oxide, as measured in terms of the relative resistance ($R_s=R_{gas}/R_{air}$), occurred at $300^{\circ}C$ with a value of 8.0 at 1 ppm $NO_2$ gas. The response and recovery times were within 60 seconds and 2 min, respectively. The sensing properties of the $NO_2$ gas showed good linear behavior with an increase of gas concentration. This study confirms that a MEMS-based gas sensor is a potential candidate as an automobile gas sensor with many advantages: small dimension, high sensitivity, short response time and low power consumption.

Fabrication of Hot Electron Based Photovoltaic Systems using Metal-semiconductor Schottky Diode

  • Lee, Young-Keun;Jung, Chan-Ho;Park, Jong-Hyurk;Park, Jeong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.305-305
    • /
    • 2010
  • It is known that a pulse of electrons of high kinetic energy (1-3 eV) in metals can be generated with the deposition of external energy to the surface such as in the absorption of light or in exothermic chemical processes. These energetic electrons are not in thermal equilibrium with the metal atoms and are called "hot electrons" The concept of photon energy conversion to hot electron flow was suggested by Eric McFarland and Tang who directly measured the photocurrent on gold thin film of metal-semiconductor ($TiO_2$) Schottky diodes [1]. In order to utilize this scheme, we have fabricated metal-semiconductor Schottky diodes that are made of Pt or Au as a metallic layer, Si or $TiO_2$ as a semiconducting substrate. The Pt/$TiO_2$ and Pt/Si Schottky diodes are made by PECVD (Plasma Enhanced Chemical Vapor Deposition) for $SiO_2$, magnetron sputtering process for $TiO_2$, e-beam evaporation for metallic layers. Metal shadow mask is made for device alignment in device fabrication process. We measured photocurrent on Pt/n-Si diodes under AM1.5G. The incident photon to current conversion efficiency (IPCE) at different wavelengths was measured on the diodes. We also show that the steady-state flow of hot electrons generated from photon absorption can be directly probed with $Pt/TiO_2$ Schottky diodes [2]. We will discuss possible approaches to improve the efficiency of photon energy conversion.

  • PDF

Evaluation of Bioactivity of Ti-6Al-7Nb Alloys with Various Hydrothermal Treatment Times (열수처리 시간에 따른 Ti-6Al-7Nh 합금의 생체활성 평가)

  • Kwon O. S.;Choi S. K.;Park K. B.;Lee M. H.;Bae T. S.;Lee O. Y.
    • Korean Journal of Materials Research
    • /
    • v.14 no.12
    • /
    • pp.876-884
    • /
    • 2004
  • This study was to investigate whether the bioactivity of the anodized and hydrothermally treated Ti-6Al-7Nb alloy were affected by the time of hydrothermal treatment. Anodizing was performed at current density 30 $mA/cm^2$ up to 300 V in electrolyte solutions containing $DL-{\alpha}-glycerophosphate$ disodium salt hydrate $(DL-{\alpha}-GP)$ and calcium acetate (CA). Hydrothermal treatment was done at $300^{\circ}C$ for 30 min, 1 hr, 2 hrs, and 4 hrs to produce a thin film layer of hydroxyapatite (HA). The bioactivity was evaluated from HA formation on the surfaces in a Hanks' solution with pH 7.4 at $36.5^{\circ}C$ for 10, 20, and 30 days. Anodic oxide films were porous with pore size of $1\sim4{\mu}m\;and\;3\sim4{\mu}m$ thickness. The anodic oxide films composed with strong anatase peak with presence of rutile peak, and showed the increase in intensity of anatase peak after hydrothermal treatment. It was shown that the intensity of anatase peak increased with increasing the time of hydrothermal treatment but was no difference in rutile peak. The corrosion voltage was the highest in the group of hydrothermal treatment for 2 hrs (Ecorr: -338.6 mV). The bioactivity in Hank's solution was accelerated with increasing the time of hydrothermal treatment.

Investigation of Top-Contact Organic Field Effect Transistors by the Treatment Using the VDP Process on Dielectric

  • Kim, Young-Kwan;Hyung, Gun-Woo;Park, Il-Houng;Seo, Ji-Hoon;Seo, Ji-Hyun;Kim, Woo-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.54-60
    • /
    • 2007
  • 이 논문에서는 게이트 절연막 위에 vapor deposition polymerization(VDP)방법을 사용하여 성막한 유기 점착층을 진공 열증착하여 유기 박막 트랜지스터(OTFTs)소자를 제작할 수 있음을 증명하였다. 우리가 제작한 Staggered-inverted top-contact 구조를 사용한 유기 박막 트랜지스터는 전기적 output 특성이 포화 영역안에서는 포화곡선을, triode 영역에서는 비선형적인 subthreshold를 확실히 볼 수 있음을 발견했다. $0.2{\mu}m$ 두께를 가진 게이트 절연막위에 유기 점착층을 사용한 OTFTs의 장 효과 정공의 이동도와 문턱전압, 그리고 절멸비는 각각, 약 0.4cm2/Vs, -0.8V, 106 이 측정되었다. 게이트 절연막의 점착층으로써 폴리이미드의 성막을 위해, 스핀코팅 방법 대신 VDP 방법을 도입하였다. 폴리이미드 고분자막은 2,2bis(3,4-dicarboxyphenyl)hexafluoropropane dianhydride(6FDA)와 4,4'-oxydianiline(ODA)을 고진공에서 동시에 열 증착 시킨 후, 그리고 $150^{\circ}C$에서 1시간, 다시 $200^{\circ}C$에서 1시간 열처리하여 고분자화된 막을 형성하였다. 그리고 점착층이 OTFTs의 전기적 특성에 주는 영향을 설명하기 위해 비교 연구하였다.

Highly stable Zn-In-Sn-O TFTs for the Application of AM-OLED Display

  • Ryu, Min-Ki;KoPark, Sang-Hee;Yang, Shin-Hyuk;Cheong, Woo-Seok;Byun, Chun-Won;Chung, Sung-Mook;Kwon, Oh-Sang;Park, Eun-Suk;Jeong, Jae-Kyeong;Cho, Kyoung-Ik;Cho, Doo-Hee;Lee, Jeong-Ik;Hwang, Chi-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.330-332
    • /
    • 2009
  • Highly stable bottom gate thin film transistors(TFTs) with a zinc indium tin oxide(Zn-In-Sn-O:ZITO) channel layer have been fabricated by rf-magnetron co-sputtering using a indium tin oxide(ITO:90/10), a tin oxide and a zinc oxide targets. The ZITO TFT (W/L=$40{\mu}m/20{\mu}m$) has a mobility of 24.6 $cm^2$/V.s, a subthreshold swing of 0.12V/dec., a turn-on voltage of -0.4V and an on/off ratio of >$10^9$. When gate field of $1.8{\times}10^5$ V/cm was applied with source-drain current of $3{\mu}A$ at $60^{\circ}C$, the threshold voltage shift was ~0.18 V after 135 hours. We fabricated AM-OLED driven by highly stable bottom gate Zn-In-Sn-O TFT array.

  • PDF

Fabrication of Coated Conductor by Continuous PVD Methods (연속 공정 PVD 방법에 의한 Coated Conductor 제조)

  • Ko, Rock-Kil;Chung, Jun-Ki;Kim, Ho-Sup;Ha, Hong-Soo;Shi, Dongqi;Song, Kyu-Jeong;Park, Chan;Yoo, Sang-Im;Moon, Seung-Hyun;Kim, Young-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1241-1245
    • /
    • 2004
  • Continuous physical vapor deposition (PVD) method is one of many processes to fabricate long length coated conductor which is required for successful large-scale application of superconducting power devices. Three film deposition systems (pulsed laser deposition, sputtering, and evaporation) equipped with reel-to-reel(R2R) metal tape moving apparatus were installed and used to deposit multi-layer oxide thin films. Both RABiTS and IBAD texture templates are used. IBAD template consists of CeO$_2$(PLD)/YSZ(IBAD) on stainless steel(SS) metal tape, and RABiTS template has the structure of CeO$_2$/YSZ/Y$_2$O$_3$ which was continuously deposited on Ni-alloy tape using R$_2$R evaporation and DC reactive sputtering in a deposition system designed to do both processes. 0.4 m-long coated conductor with Ic(77 K) of 34 A/cm was fabricated using RABiTS template. 0.5 m and 1.1 m-long coated conductor with Ic(77 K) of 41 A/cm and 26 A/cm were fabricated using IBAD template.