• 제목/요약/키워드: 3-dimensional analysis

검색결과 6,701건 처리시간 0.038초

Metabolic Characteristic of the Liver of Dairy Cows during Ketosis Based on Comparative Proteomics

  • Xu, Chuang;Wang, Zhe;Liu, Guowen;Li, Xiaobing;Xie, Guanghong;Xia, Cheng;Zhang, Hong You
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권7호
    • /
    • pp.1003-1010
    • /
    • 2008
  • The objective of the present study was to identify differences in the expression levels of liver proteins between healthy and ketotic cows, establish a liver metabolic interrelationship of ketosis and elucidate the metabolic characteristics of the liver during ketosis. Liver samples from 8 healthy multiparous Hostein cows and 8 ketotic cows were pooled by health status and the proteins were separated by two-dimensional-electrophoresis (2D-E). Statistical analysis of gels was performed using PDQuest software 8.0. The differences in the expression levels of liver proteins (p<0.05) between ketotic and healthy cows were identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF-TOF) tandem mass spectrometry. Five enzymes/proteins were identified as being differentially expressed in the livers of ketotic cows: expression of 3-hydroxyacyl-CoA dehydrogenase type-2 (HCDH), acetyl-coenzyme A acetyltransferase 2 (ACAT) and elongation factor Tu (EF-Tu) were down-regulated, whereas that of alpha-enolase and creatine kinase were up-regulated. On the basis of this evidence, it could be presumed that the decreased expression of HCDH, which is caused by high concentrations of acetyl-CoA in hepatic cells, in the livers of ketotic cows, implies reduced fatty acid ??oxidation. The resultant high concentrations of acetyl-CoA and acetoacetyl CoA would depress the level of ACAT and generate more ??hydroxybutyric acid; high concentrations of acetyl-CoA would also accelerate the Krebs Cycle and produce more ATP, which is stored as phosphocreatine, as a consequence of increased expression of creatine kinase. The low expression level of elongation factor Tu in the livers of ketotic cows indicates decreased levels of protein synthesis due to the limited availability of amino acids, because the most glucogenic amino acids sustain the glyconeogenesis pathway; thus increasing the level of alpha-enolase. Decreased protein synthesis also promotes the conversion of amino acids to oxaloacetate, which drives the Krebs Cycle under conditions of high levels of acetyl-CoA. It is concluded that the livers of ketotic cows possess high concentrations of acetyl-CoA, which through negative feedback inhibited fatty acid oxidation; show decreased fatty acid oxidation, ketogenesis and protein synthesis; and increased gluconeogenesis and energy production.

Rogers 이론에 근거한 가족양상 사정지침개발 (Development of a Family Pattern Appraisal to Guide a Rogerian Nursing Practice)

  • 이광옥;한영란;김희정
    • 대한간호학회지
    • /
    • 제25권4호
    • /
    • pp.751-773
    • /
    • 1995
  • We, clinical nurse specialists practising and guiding student practice in a Community health nursing clinic, wanted to develop a family pattern appraisal consistent with Rogers' conceptual system, the nursing model guiding our practice. We use Rogers' model because it is harmonious with the traditional Korean view of the one human, natural and cosmic world. The purpose of our research was to contribute to science - based nursing practice, not only, one helpful model, but also a model of how to use, in guiding practice, a conceptual system which reflects nurse practitioners' philosophy of nursing, is intellectually satisfying, and enriches meaning in daily nursing life. The research objectives were to review the literature on Rogers' model and analyse it according to Kim's five - level analytical framework, to explore Rogers' definition of family, to review appraisals based on Rogers' model, and to develop a family appraisal which is culturally appropriate for use in our community. This work including the use of the appraisal and its refinement with families in our practice which was done during 1994 and 1995, in Seoul, in the Capital of the Republic of Korea. At the highest level of analysis, Rogers conceptual system emphasizes acausality and multidimentional meaning ; the world view is characterized by process, movement and wholeness. The epistemology Is one of holism and the knowledge base includes all forms of experience, from sensory to mystical, objective, and subjective. At the metaparadigm level, nursing focuses on the unitary human being and the environment. At the level of nursing philosophy, the model identifies human being, nursing, nurse, and illness and health. At the paradigm level the model assumes the irriducibility of the human to parts, noncausality and continual change. Rogers' practice methodology consists of pattern manifestation appraisal and deliberative mutual patterning. Under-standing patterns and patterning of people is the key to helping them achieve their potential. At the theory level, the basic assumptions, key concepts, and homeodynamic principles were identified. Rogers states the family energy field is an undividable, four-dimensional negentropic energy field which is in a larger envircinmental field show-ing such characteristics as cannot be predicted by knowledge of individual family members. Based on the word of Rogers scholars, we chose Rogers' correlates of patterning to understand the family unit as a whole-frequency, rhythms, motion, time perception, sleeping-waking beyond waking, pragmatic -imaginative-visionary to develop the appraisal. We, also used some of Barrel's (1988) criteria including interpersonal network and professional health care access and use, and Cordon's (1982) criteria including self perception - self concept modified to fit the family. Our family Pattern appraisal included 1. Influencirg data, 2. Professional health care access and use, 3. Family self perception-self concept, 4. Family interpersonal network, 5. Sleep-wake-be-yond waking, 6. Pragmatic-imaginary-visionary, 7. Family frequency and rhythm, 8. Family motion, 9. Family time perception. The appraisal was used with four families and modified to eliminate overlap and to make it possible for the family member to express themselves more easily. We plan to gain more experience with the appraisal toward further development of the tool.

  • PDF

퍼터헤드 회전중심점 위치 관점에서 본 남자프로골퍼의 10.94 m 퍼팅동작의 진자운동 여부 (Is Male Professional Golfers' 10.94 m Putting Motion a Pendulum Motion? From a Point of View of the Location of the Center of Putter Head Rotation)

  • 박영훈;염창홍;서국웅
    • 한국운동역학회지
    • /
    • 제17권2호
    • /
    • pp.217-226
    • /
    • 2007
  • Putting score counts about 43 % of the golf score. The dominant idea of the putting motion to amateur golfers as well as to many professional golfers is a pendulum-like motion. If a golfer's putting stroke motion is a pendulum-like motion, the putting motion should be straight-back-and-through, the same backswing, downswing, and follow through length and period, and a swing with a fixed hinge joint. If the putting motions of the human are different from the pendulum motion, there could be confusion in understanding and teaching golf putting. The purpose of this study was to examine the center of rotation(COR) of the putter head to reveal whether professional golfers really putt like a pendulum. Thirteen male professional golfers were recruited for the study. Each golfers executed 10.94 m putts six times on an artificial grass mat. Putter head position data were collected through a 60 Hz three-dimensional motion analysis system and low pass filtered with cut-off frequency of 6 Hz. COR of the putter head was mathematically acquired. Each golfer's last five putting motions were considered. The results show that the COR of the putter head was neither fixed nor located inside of the golfer. The medio-lateral directional component of the COR of the putter head fluctuated in the range of 10 cm during downswing and follow through. The anterior-posterior directional component of the COR of the putter head was fixed from the beginning of the downswing through impact. Just after impact, however, it moved to the target up to 60 cm. The superior-inferior directional component of COR of the putter head moved in a superior direction with the beginning of the downswing and showed peak height just prior to impact. During the follow through, it moved back in an inferior direction. The height-normalized peak value of the COR of the putter head was $1.4{\pm}0.3$ height. Technically speaking, male professional golfers' 10.94 m putting motion is not a pendulum-like motion. The dominating idea of a pendulum-like motion in putting might come from the image of the flawless, smooth motion of a pendulum.

골내 임플랜트의 종류에 따른 광탄성 응력 분석 (PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY DIFFERENT TYPE ENDOSSEOUS IMPLANTS)

  • 정재헌;장두익
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.661-678
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

  • PDF

임플란트 보철물의 점하중과 면하중에 따른 유한요소법적 응력 분석 (Finite element stress analysis according to the point and surface occlusal loads on the implant prosthesis)

  • 최민호;강재석;부수붕;오상호;안옥주;강동완
    • 구강회복응용과학지
    • /
    • 제20권2호
    • /
    • pp.83-94
    • /
    • 2004
  • The purpose of this study was to compare the distributing pattern of stress according to the types of occlusal load on the finite element models of the splinted implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on mandibular first and second molars. The cemented crowns for mandibular first and second molars were made. Three-dimensional finite element model was created with the components of the implant, surrounding bone and cemented crowns. Two types of occlusal load, the point load and the surface load within 0.5 mm radius circle, were applied to the finite element models with 200N magnitude in axial(along the long axis of the implant and oblique(angulation of $30^{\circ}$ to the long axis) directions perpendicular to cuspal incline. Loads were positioned from the center of central fossa and to distance of 2 mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the fixtures and sections. The results were as following : 1. Under axial loading at the central fossa, the stress was distributed along the fixture except for the apical portion, not relative to both point & surface contacts. 2. With offset distance increasing, the highest stresses were concentrated in the neck portion of the fixture. 3. The maximum von Mises stress under the oblique load was greater than that under the axial load. 4. Under the oblique load, the highest stress were concentrated in the buccal side and lingual neck portion of the fixture with offset distance increasing. The results had a tendency to increase the stress on the neck portion of fixture with the offset and oblique loads increasing. The design of occlusal scheme should be allowed to distribute stress axially in maximum intercuspation and to decrease the angulation of cuspal incline.

치조골 높이가 다른 임프란트 주위 지지골 응력분석 (Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level)

  • 부수붕;정제옥;이승훈;김창현;이승호
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.55-68
    • /
    • 2007
  • The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

티타늄 나프테네이트를 이용한 나노결정질 $TiO_2$ 광촉매 박막의 제조 (Preparation of nanocrystalline $TiO_2$ photocatalyst films by using a titanium naphthenate)

  • 이선옥;김상복;윤연흠;강보안;황규석;오정선;양순호;김병훈
    • 한국결정성장학회지
    • /
    • 제12권5호
    • /
    • pp.240-246
    • /
    • 2002
  • 티타늄 나프테네이트를 출발 원료로 사용하고 스핀코팅-열분해법을 이용하여 소다-라임-실리카 슬라이드 유리기판 위에 $TiO_2$ 박막을 제조하였다. 도포된 박막은 $500^{\circ}C$로 10분간 공기분위기에서 전열처리를 행하였고, 최종 열처리는 500, 550과 $600^{\circ}C$로 30분간 공기분위기에서 각각 행하였다. X-선 회절분석법을 이용하여 박막의 결정화도를 조사하였고, 전계 방출 주사형 전자 현미경과 원자간력 현미경을 이용하여 $TiO_2$ 박막의 표면미세구조와 표면 거칠기를 조사하였다. 550 과 $600^{\circ}C$로 최종 열처리한 박막의 X-선 회절분석 결과, 아나타제 상만이 존재하였다. 500과 $550^{\circ}C$로 열처리한 박막의 표면은 균질하였으나, 열처리온도가 $600^{\circ}C$로 증가함에 따라서, 박막의 표면에는 바늘모양의 상이 3차원적으로 성장하였다. 모든 박막에 있어서 가시영역에서의 투과율은 500nm에서 90% 이상의 높은 값을 나타냈다. 박막의 광촉매특성을 조사하기 위하여 stearic acid가 코팅된 박막에 365nm 파장의 UV를 2.4mW/$\textrm{cm}^2$의 강도로 조사하여 C-H모드에 대한 IR 흡수단의 변화를 관찰하였다.

열(熱)흐름을 동반(同伴)한 정상지하수(定常地下水)의 흐름해석(解析) 수치모형(數値模型) (A Numerical Model for Analysis of Groundwater Flow with Heat Flow in Steady-State)

  • 왕수균;조원철;이원환
    • 대한토목학회논문집
    • /
    • 제11권4호
    • /
    • pp.103-112
    • /
    • 1991
  • 본(本) 연구(硏究)는 일정균등(一定均等)한 열적(熱的) 특성(特性)을 가지고 있으며 상변화(相變化) 없는 등방(等方) 이질성(異質性)의 3차원(次元) 대수층계(帶水層系)의 열(熱)흐름과 정상상태(定常狀態)의 지하수(地下水)흐름을 모의발생(模擬發生)할 수 있는 유한차분(有限差分) 모형(模型)을 확립(確立)한 것이다. 이 모형(模型)은 대규모(大規模) 지하수(地下水) 흐름체계(體系)에서 폐기물(廢棄物)의 지하저류시(地下貯溜時) 지하수(地下水) 흐름과 발생(發生) 혹은 주입(注入)된 열(熱)의 흐름을 예측(豫測) 분석(分析)하기 위하여 확립(確立)된 것이다. 이러한 대수층계(帶水層系)의 지하수(地下水) 흐름에 작용(作用)하는 조건(條件)으로는 강우주입(降雨注入)으로 인한 수문학적(水文學的) 조건(條件)과 고정(固定)된 수리수두(水理水頭) 경계조건(境界條件) 등(等)이 포함(包含)되고, 열(熱)흐름에는 지열(地熱)의 흐름, 지표면(地表面)으로의 전도(傳導), 주입(注入)에 의한 이류(移流), 고정(固定) 수두경계(水頭境界)로 향(向)한 또는 고정수두경계(固定水頭境界)로 부터의 이류(移流) 등(等)이 포함(包含)된다. 본(本) 모형(模型)에서는 지하수(地下水)흐름과 열(熱)흐름 방정식(方程式)을 번갈아 푸는 교대반복과정(交代反復過程)을 사용(使用)하고, 두 방정식(方程式)의 계산(計算)에는 직접해법(直接解法)을 사용(使用)한다. 이동시간(移動時間)은 모형공간(模型空間)에서 입자추적(粒子追跡)으로 결정(決定)되며, 분할(分轄)된 구역내(區域內)의 지하수(地下水) 유속(流速)은 구역내(區域內)의 유속(流速)을 선형(線形)으로 보간(補間)하여 계산(計算)한다. 본(本) 모형(模型)을 경상북도(慶尙北道) 영일군(迎日郡) 송라면(松羅面) 지경리(地境里) 일대(一帶)의 지하수계(地下水系)에 적용(適用)하여 이 일대(一帶) 지하(地下) 암반층(岩盤層)의 수두분포(水頭分布), 유동로(流動路), 이동시간(移動時間) 및 지하수온분포(地下水溫分布)를 계산(計算)하여 지하수(地下水) 유동체계(流動體系)를 분석(分析)하였다.

  • PDF

Role of ghrelin in the pancreatic exocrine secretion via mitogen-activated protein kinase signaling in rats

  • Lee, Kyung-Hoon;Lee, Jae-Sung;Wang, Tao;Oh, Jin-Ju;Roh, Sanggun;Lee, Hong-Gu
    • Journal of Animal Science and Technology
    • /
    • 제59권7호
    • /
    • pp.16.1-16.6
    • /
    • 2017
  • Background: This study was performed to investigate the impact of exogenous ghrelin on the pancreatic ${\alpha}$-amylase outputs and responses of pancreatic proteins to ghrelin that may relate to pancreatic exocrine. Methods: Sprague-Dawley male rats (9 weeks old, $300{\pm}10g$) were injected with ghrelin via intraperitoneal (i.p.) infusion at dosage of 0, 0.1, 1.0 and $10.0{\mu}g/kg$ body weight (BW), respectively. The plasma ghrelin and cholecystokinin (CCK) level were determined using enzyme immunoassay kit; the mRNA expression of ghrelin receptor ($GHSR-1{\alpha}$) and growth hormone (GH) receptor were assessed by reverse transcription PCR; the expressions of pancreatic ${\alpha}$-amylase activity, extracellular-signal-regulated kinases (ERK), phosphorylated extracellular-signal-regulated kinases (pERK) and c-Jun N-terminal kinase (JNK) were evaluated by western blotting; moreover the responses of pancreatic proteins to ghrelin were analyzed using the two-dimensional gel electrophoresis system. Results: The exogenous ghrelin (1.0 and $10.0{\mu}g/kg\;BW$) elevated the level of plasma ghrelin (p < 0.05), and suppressed the expression of pancreatic ${\alpha}$-amylase at a dose of $10.0{\mu}g/kg\;BW$ (p < 0.05). No difference in the level of plasma CCK was observed, even though rats were exposed to any dose of exogenous ghrelin. In addition, a combination of western blot and proteomic analysis revealed exogenous ghrelin ($10.0{\mu}g/kg\;BW$) induced increasing the JNK and ERK expressions (p < 0.05) and four proteins such as Destrin, Anionic trypsin-1, Trypsinogen, and especially eukaryotic translation initiation factor 3 in rat pancreas. Conclusions: Taken together, exogenous ghrelin by i.p. infusion plays a role in the pancreatic exocrine secretion via mitogen-activated protein kinase signaling pathway.

선호 차종별 자동차 네비게이션 시스템의 감성평가 (Sensibility Evaluation for Car Navigation System based on Vehicle-type Preference)

  • 박성준;김성훈
    • 한국산업정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.71-79
    • /
    • 2004
  • 자동차의 급격한 증가로 인하여 교통 정체현상이 날로 심해짐에 따라 운전자에게 보다 안전하고 쾌적한 운전 편의성을 제공하기 위한 방법으로 차량항법장치(CNS)가 제안되었으며, 최근에 출시되는 많은 차량에 카 네비게이션 시스템이 장착되고 있다. 또한 네비게이션 시스템이 단순한 차량 항법 장치로서의 위치를 넘어 차량 내 멀티미디어 시스템으로서의 기능을 감당하고 있으며, 이에 따라 자동차 내장(Interior)의 중요한 부품으로 인식되고 있다. 따라서 기능뿐만 아니라 사용성과 외형적 디자인 역시 소비자의 취향에 맞게 설계되어질 필요성이 있다. 본 연구에서는 자동차 내장 부품의 구성 요소로서의 카 네비게이션 시스템에 대하여 소비자들이 요구하는 감성요소가 무엇인지 파악해 보았다. 특히, 소비자들이 선호하는 차종에 따라 내장 부품의 감성 특성 역시 변화될 수 있으므로 차량 선호도에 기초하여 감성요소 분석을 실시하였으며, 소비자 특성별 감성 선호도 도출 기법으로서 다차원 척도법(MDS)기법의 효용성을 입증해보았다. 정통적인 세단 형태의 차종을 선호하는 사람의 경우, 네비게이션 시스템에 대하여 고급감, 조화감, 재질감을 요구하였으며, 스포츠카를 선호하는 사람의 경우는, 팬시감, 개성감, 역동감을, SUV와 MPV를 선호하는 사람의 경우는 견고감과 역동감, 편의감을 중요시하는 것으로 분석되었다.

  • PDF