• Title/Summary/Keyword: 3-Level PCS

Search Result 61, Processing Time 0.024 seconds

Compensation of Unbalanced Neutral Voltage for Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS Using Offset Voltage (오프셋 전압을 이용한 계통 연계형 3상 3레벨 T-type 태양광 PCS의 중성점 전압 불평형 보상)

  • Park, Kwan-Nam;Choy, Ick;Choi, Ju-Yeop;Lee, Young-Kwoun
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.1-12
    • /
    • 2017
  • The DC link of Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS (PV-PCS) consists of two series connected capacitors for using their neutral voltage. The mismatch between two capacitor characteristics and transient states happened in load change cause the imbalance of neutral voltage. As a result, PV-PCS performance is degraded and the system becomes unstable. In this paper, a mathematical model for analyzing the imbalance of neutral voltage is derived and a compensation method using offset voltage is proposed, where offset voltage adjusts the applying time of P-type and N-type small vectors. The validity of the proposed methods is verified by simulation and experiment.

Development of Leakage Current Reduction Method in 3-Level Photovoltaic PCS (3레벨 태양광 PCS에서의 누설전류 저감기법 개발)

  • Han, Seongeun;Jo, Jongmin;An, Hyunsung;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, a reduction method of leakage current in a three-level photovoltaic power-conditioning system (PCS) is proposed and verified by simulation and experiment. Leakage current generation is analyzed through an equivalent model of the common mode voltage considering a significant parasitic capacitance existing between the photovoltaic array and ground. A leakage current reduction method using pulse-width modulation (PWM) method is also proposed, and a 10-kW three-level photovoltaic PCS simulation and experiment is performed with a $1{\mu}F$ parasitic capacitor based on 100 nF/kW. The proposed method using the PWM method is verified to reduce the leakage current by 73% compared with the conventional PWM method.

Expression of Arabidopsis Phytochelatin Synthase 2 Is Too Low to Complement an AtPCS1-defective Cad1-3 Mutant

  • Lee, Sangman;Kang, Beom Sik
    • Molecules and Cells
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 2005
  • Phytochelatins play an important role in heavy metal detoxification in plants as well as in other organisms. The Arabidopsis thaliana mutant cad1-3 does not produce detectable levels of phytochelatins in response to cadmium stress. The hypersensitivity of cad1-3 to cadmium stress is attributed to a mutation in the phytochelatin synthase 1 (AtPCS1) gene. However, A. thaliana also contains a functional phytochelatin synthase 2 (AtPCS2). In this study, we investigated why the cad1-3 mutant is hypersensitive to cadmium stress despite the presence of AtPCS2. Northern and Western blot analyses showed that expression of AtPCS2 is weak compared to AtPCS1 in both roots and shoots of transgenic Arabidopsis. The lower level of AtPCS2 expression was confirmed by RT-PCR analysis of wild type Arabidopsis. Moreover, no tissue-specific expression of AtPCS2 was observed. Even when AtPCS2 was under the control of the AtPCS1 promoter or of the cauliflower mosaic virus 35S promoter (CaMV 35S) it was not capable of fully complementing the cad1-3 mutant for cadmium resistance.

A sudy on the Out-of-band Noise Power for PCS Unified Repeater (PCS 통합중계기의 대역외 잡음에 관한 연구)

  • 황선호;김훈석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.359-362
    • /
    • 2002
  • The increase in the number of PCS base station and repeater has increased the level of interference between PCS carriers. In this paper, interference of singular PCS repeater out-of-band noise power on mobile phone is analysed and compared with that of unified PCS repeater for multiple PCS carriers. It is shown that unified PCS repeater provide about 2∼3dB signal gain in comparison with conventional PCS repeater. As a result, the interference of out-of-band noise power on mobile phone is reduced. It is expected that PCS carriers are able to build an environmentally-friendly communications infrastructure and reduce the cost by using unified PCS revealer and apply it for the deployment of IMT-2000 network.

  • PDF

Investigating the Level of Competition between Public Health Centers and Private Clinics in Korea

  • Kim, Hyun Joo;Lee, Jin Yong;Jo, Min-Woo;Eun, Sang Jun
    • Korea Journal of Hospital Management
    • /
    • v.21 no.2
    • /
    • pp.37-49
    • /
    • 2016
  • The purpose of this study is to investigate the level of competition between Public Health Centers (PHCs) and private clinics (PCs) by examining the number of patients that used PHCs vs. PCs, estimating the total amount of revenue generated from outpatient services at both PHCs and PCs, thereby analyzing the financial impacts on PCs derived from the PHCs. We utilized 2011 National Inpatient Sample data (NIS). Using the 20 table containing general information on each individual claims, we integrate it with the 40 table which contains all the diagnostic codes for each claim. Then, we disaggregate the bundled claims into the original individual claims. Overall, 3.1% of outpatient visits are made at PHCs while the rest was made at the PCs (96.9%). Among the total claim costs of 6.34 billion USD (as of 2011), PHCs occupy 2.0% (124 million USD), and 98.0% are contributed to PCs (6.21 billion USD). The estimated economic losses of PCs due to PHCs are summarized as follow; the maximum potential loss is estimated at 198 million USD in total and 7,099 USD per clinic when we include all patient types; the minimum loss is estimated at 71 million USD in total and 2,540 USD per clinic where Medical Aid recipients and the elderly (aged 65 and over) are excluded. Our results confirm the potential economic effect on PCs due to PHCs providing outpatient services. PCs and PHCs are the most important players providing primary care in Korea. Unnecessary competition between PCs and PHCs is not desirable. Health authorities should carefully examine the healthcare services currently provided by PHCs and their impacts on PCs.

Experimental Test for Seismic Performance of PCS Structural System (PCS 구조 시스템의 내진 성능 분석)

  • Park, Soon-Kyu;Yeo, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.313-322
    • /
    • 2007
  • The PCS system, which consists of precast concrete column and steel beam, is a kind of composite structural systems. In this paper, experimental study has been conducted to analyze seismic performance of bolted beam-to-column connections for the PCS system. Based on experimental results from the seismic testing of eight interior PCS specimens, it shows that behavior of PCS system is satisfactory to seismic performance criteria of ACI such as strength deterioration, stiffness degradation and energy dissipation capacity except initial stiffness. All of the specimens maintain their strength at large levels of story drift without significant loss of stiffness and show high ductility level for inelastic behavior. The energy dissipation capacity is two times greater than requirement of ACI criterion. But the initial stiffness of all specimens does not satisfy ACI criterion, and this phenomenon is similar to the other composite structural systems such as RCS, CFT system.

A Study on the MPPT Control Method for Grid-connected Multi-String Three-Phase Three-Level PV Inverter (계통연계형 멀티스트링 3상 3레벨 태양광 인버터의 MPPT 제어방법에 관한 연구)

  • Kim, Jinsoo;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.43-48
    • /
    • 2014
  • Two-level inverter has some disadvantages like high harmonics contained in the output current, efficiency limit and stress to switching device as IGBT and FET. Many researches have reported multi-level inverter to complement two-level inverter of problems. In this paper, we suggest MPPT algorithm of multi-string three-level solar inverter that considered nowadays. We added midpoint controller in order to implement the MPPT algorithm because the three-level inverter has to need midpoint controller and procured the stability of direct current link. We verify the superiority of multi-string T-Type inverter and the algorithm we suggested with solar irradiance variation experiment and MPPT efficiency measurement. The MPPT efficiency was confirmed with a high efficiency more than 99.97%.

Design of 10kW 3-level Photovoltaic PCS Gate driver (10kW급 3레벨 태양광 PCS 게이트드라이버 설계)

  • Han, Seongeun;Jo, Hyunsik;Lee, Jaedo;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.449-450
    • /
    • 2017
  • 본 논문은 계통연계 10kW급 3레벨 태양광 PCS(Power Conditioning System) 게이트 드라이버 설계에 대해 서술하였다. 게이트 드라이버는 DSP로부터 신호를 받아 정해진 시간에 IGBT의 게이트에 문턱전압 이상의 전압을 공급하여 IGBT의 게이트를 구동해 주는 역할을 한다. 게이트 드라이버는 간결한 회로의 사용으로 에너지 손실과 제작비용을 최소한으로 저감해야한다. 설계된 10kW급 3레벨 태양광 PCS 게이트 드라이버의 파워부는 15V 전압을 받아 PSIM 시뮬레이션을 통해 확인하였고 이를 실험하여 이상 없이 동작함을 검증하였다.

  • PDF

A Study on the Multi-level PV-PCS Using Cascade 3-Phase Transformer (직렬형 3상 변압기를 이용한 다중레벨 PV-PCS)

  • Kim, Ki-Seon;Song, Sung-Geun;Cho, Su-Eog;Choi, Joon-Ho;Kim, Kwang-Heon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2359-2369
    • /
    • 2009
  • The study on the multi-level inverter has been increasingly progressing to reduce the switching loss and improve the THD of output current in photovoltaic inverter. Recently, the main topics of multi-level inverter are to reduce the number of devices maintaining the power quality. Therefore, the novel topology was proposed for these problem which is composed of the isolated H-bridge multi-level inverter using the three phase low frequency transformer. The proposed multi-level inverter may not be need for a independent DC power, diode and capacitor. Specially, It has a advantage in generating high voltage source. The proposed approach is verified through simulation and experiment.

A Study on the Controller Design of the Three-Level Boost Converter for Photovoltaic Power Conditioning System (태양광 발전 시스템용 3-레벨 부스트 컨버터 제어기 설계에 관한 연구)

  • Lee, Kyu-Min;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.227-236
    • /
    • 2021
  • This research proposes a modeling and controller design of a three-level boost (TLB) converter for the implementation of maximum power point tracking (MPPT) in the photovoltaic power conditioning system (PCS). Contrary to the output voltage control of the conventional controller, the Photovoltaic PCS requires an input voltage controller for MPPT operation. A TLB converter has the advantage of decreasing the inductor size and increasing efficiency compared with the existing booster converter. However, an optimal controller is difficult to design due to the complexity of the TLB operations, which have two operational modes on the duty ratio boundary of 0.5. Therefore, the unified linear model equations of the TLB converters, which can be applicable to both operational modes, are derived using linearized solar cell expressions. Furthermore, the transfer functions are obtained for the controller design. The MPPT voltage controller is designed using MATLAB SISOTOOL. In addition, a controller for capacitor voltage unbalancing is described and designed. The simulations and experimental verifications are conducted to verify the effectiveness of the small-signal analysis and control system design.