• Title/Summary/Keyword: 3 T

Search Result 44,512, Processing Time 0.078 seconds

Determination of Representative Renal Depth for Accurate Attenuation Correction in Measurement of Glomerular Filtration Rate in Transplanted Kidney (이식 신의 사구체 여과율 측정에서 정확한 감쇄 보정을 위한 신장 깊이 대표값 설정)

  • Oh, Soon-Nam;Kim, Sung-Hoon;Rha, Sung-Eun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2002
  • Purpose: To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. Materials and Methods: We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured GFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depths under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. Results: The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are $4.09{\pm}0.65cm$ in men, and $4.24{\pm}0.78cm$ in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. Conclusion: When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

Study on Effect of Convection Current Aeration System on Mixing Characteristics and Water Quality of Reservoir (대류식 순환장치의 저수지수체 유동특성 및 수질영향)

  • Lee, Yo-Sang;Lee, Kwang-Man;Koh, Deok-Koo;Yum, Kyung-Taek
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.1
    • /
    • pp.85-94
    • /
    • 2009
  • This study examines the operational effectiveness of a Convection Current Aeration System (CCAS) in reservoir. CCAS was run from June, 2008 when the thermocline begun forming in the reservoir. This paper reviews the influence of stratification, dissolved oxygen dynamics and temperature in the lake's natural state from June to October 2008. The survey was done on a week basis. Upwelling flow effects a radius of $7{\sim}10m$ at a surface directly and was irrelevant to the strength of thermocline. On the other hand, it was affected the number of working days, and strength of thermocline at vertical profiles of the reservoir. Longer CCAS run, the deeper was the vertical direct flow area. However it didn't break the thermocline during summer season of 2008. The operating efficiency of the CCAS in the reservoir depends on hydraulics and meteological conditions. Computational Fluid Dynamics (CFD) is a very useful tool for evaluating the operating efficiency of fluid dynamics. The geometry for CFD simulation consists of a cylindrical vessel 25 m radius and 40 m height. The CCAS is located in center of domain. The non-uniform tetrahedral meshes had a bulk of the geometry. The meshes ranged from the coarse to the very fine. This is attributed to the cold water flowing into the downcomer and rising, creating a horizontal flow to the top of the CCAS. The result of CFD demonstrate a closer agreement with surveyed data for temperature and flow velocity. Theoretical dispersion volume were calculated at 8m depth, 120 m diameter working for 30 days and 10 m depth, 130 m diameter working for 50 days.

Effects of Pig Slurry Application on Body Weight Gain of Grazing Hanwoo Heifer and Forage Yields in a Grass-Legume Mixed Pasture (방목초지 돈분액비 시용이 목초 생산성 및 방목한우 증체에 미치는 영향)

  • Ko, S.B.;Park, N.G.;Hwang, K.J.;Lee, C.E.;Kang, S.Y.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.4
    • /
    • pp.255-264
    • /
    • 2003
  • A study was conducted to determine the effects of pig slurry application on forage yield and growth of fazing Hanwoo heifer in a mixed pasture. To each of three treatments 1.4ha were alloted a control applied with only chemical fertilizer (N-P-K=150-150-120kg/ha), two pig slurry lots applied with the amount to allow 100% (150 kg/ha) or 150% (225 kg/ha) of N used in the control. A randomized block design was used without replication. Cattle were allowed to graze continuously during the experimental period. Results obtained were as follows: Total dry matter yield was 16,291, 15,632 and 16,320 kg/ha for chemical fertilizer. pig slurry 100% and 150%, respectively. The pasture was dominated by perenial ryegrass during the first gazing season, but by orchard grass and perenial ryegrass (60∼70%) and red clover (20∼30%) during the second grazing season. Average gazing rate per ha was 2.75∼2.76 animal units and daily weight gain of grazing cattle was not different among treatments ranging from 0.563 to 0.580 kg. Total weight gain of grazing cattle per ha during the grazing period was 541, 541 abd 555 kg for chemical fertilizer, pig -slurry 100 and 150%, respectively. RBC, WBC, total protein and albumin etc. concentrations in blood were normal in all treatments.

Antimicrobial Activity of Natural Product Made by Opuntia ficus-indica var. saboten Against Salmonella spp. and Escherichia coli O157:H7 (백련초 (Opuntia ficus-indica var., saboten)의 Salmonella와 Escherichia coli O157 : H7에 대한 항균효과)

  • Kim, So-Hyun;Kwon, Nam-Hoon;Kim, J.Y.;Lim, J.Y.;Bae, W.K.;Kim, J.M.;Noh, K.M.;Hur, J.;Jung, W.K.;Park, K.T.;Lee, J.E.;Ra, J.C.;Park, Yong-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.17 no.2
    • /
    • pp.71-78
    • /
    • 2002
  • With the incidence of antibiotic resistant bacteria there is increasing interest in natural products such as herb extract and probiotics to control antibiotic resistant bacteria. This study was focused on the determination of antimicrobial activity of Opuntia ficus-indica var. saboten against Salmonella enetrica serovar Enteritidis (S. enterifidis), S. enterica serovar Typhimurium (S. Typhimurium) DT 104 and Escherichia coli 0157:H7. Though bactericidal effect of 0. ficus-indica var. saboten was not observed, it had significant inhibitory activity against Salmonella spp. and E. coli O157:H7 on the Moulter Hinton agar containing its solution dissolved in deionized water. To investigate the antimicrobial activity in vivo, mice were challenged with 5. Typhimurium DT104 (3.7$\times$108 cfu/mouse) after pre-feeding 0. ficus-indica var. saboten solution. The fecal shedding of S. Typhimurium DT104 was more dramatically decreased and not detectable in feces and intestines 3 days after challenge in mice fed with 0. ficus-indica var. saboten. Antibody responses of the intestinal IgA were also significantly increased in mice fed with 0. ficus-indica var. saboten. These findings suggest that Opuntia ficus-indica var. saboten decreased the shedding of S. Typhimurium DT104 in vitro and also in the gastrointestinal tract in mice. In addition, administration of the product might enhance the mucosal immune response against S. Typhimurium DT 104. In conclusion, Opuntia ficus-indica var. saboten might be useful to control antibiotic resistant bacteria in vivo and in vitro.

Influential Job-Related Characteristics for the Job Satisfaction and Turnover Possibility of Dental Hygienists (치과위생사의 직무만족과 이직가능성에 영향을 미치는 직무관련특성 요인)

  • Lee, Chun-Sun;Park, So-Yong;Park, Hye-Min;You, Youn;Shin, Eun-Kyung;Chae, Song-I;Han, Seong-Ok;Oh, Hye-Young
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.666-674
    • /
    • 2012
  • The purpose of this study was to examine the job-related characteristics of dental hygienists affecting their job satisfaction and turnover possibility. The subjects in this study were 297 dental hygienists who worked in dental hospitals and clinics in the metropolitan area. The dental hygienists who worked for three to less than five years, who were unmarried and who didn't benefit from any incentive systems expressed a greater satisfaction, and those who were married, whose workplaces were established jointly with other dental institutions in the form of a network and whose workplaces offered incentives were more likely to change their employment. As for influential factors for job satisfaction and turnover possibility, the respondents whose workplaces were established jointly with other dental institutions were less satisfied, and a larger number of patients and better communication led to higher satisfaction. Those who worked in general hospitals were more likely to change their employment, and better welfare benefits, more appropriate length of working hours and a larger number of patients led to lower turnover responsibility. The findings of the study ascertained that working environments were one of the factors to impact on job satisfaction and turnover possibility, and both of hospitals and dental hygienists should make an effort to improve working environments.

(U-Th)/He Dating: Principles and Applications ((U-Th)/He 연령측정법의 원리와 응용)

  • Min, Kyoung-Won
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.239-247
    • /
    • 2014
  • The (U-Th)/He dating utilizes the production of alpha particles ($^4He$ atoms) during natural radioactive decays of $^{238}U$, $^{235}U$ and $^{232}Th$. (U-Th)/He age can be determined from the abundances of the parent nuclides $^{238}U$, $^{235}U$ and $^{232}Th$ and the radiogenic $^4He$. Because helium is one of the noble gases (non-reactive) with a relatively small radius, it diffuses rapidly in many geological materials, even at low temperatures. Therefore, ingrowth of $^4He$ during radioactive decay competes with diffusive loss at elevated temperatures during the geologic time scale, determining the amount of $^4He$ existing today in natural samples. For example, He diffusion in apatite is known to be very rapid compared to that in most other minerals, causing a significant diffusive loss at ${\sim}80^{\circ}C$ or higher. At ${\sim}40^{\circ}C$, He diffusion in apatite becomes slow enough to preserve most $^4He$ in the sample. Thus, an apatite's (U-Th)/He age represents the timing when the sample passed through the temperature range of $80-40^{\circ}C$. The crustal depth corresponding to this temperature range is called a "partial retention zone." Normal closure temperatures for a typical grain size and cooling rate are ${\sim}60-70^{\circ}C$ for apatite and ${\sim}200^{\circ}C$ for zircon and titanite. Because the apatite He closure temperature is lower than that of most other thermochronometers, it can provide critical constraints on relatively recent or shallow-crustal exhumation histories.

Key Methodologies to Effective Site-specific Accessment in Contaminated Soils : A Review (오염토양의 효과적 현장조사에 대한 주요 방법론의 검토)

  • Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.383-397
    • /
    • 1999
  • For sites to be investigated, the results of such an investigation can be used in determining foals for cleanup, quantifying risks, determining acceptable and unacceptable risk, and developing cleanup plans t hat do not cause unnecessary delays in the redevelopment and reuse of the property. To do this, it is essential that an appropriately detailed study of the site be performed to identify the cause, nature, and extent of contamination and the possible threats to the environment or to any people living or working nearby through the analysis of samples of soil and soil gas, groundwater, surface water, and sediment. The migration pathways of contaminants also are examined during this phase. Key aspects of cost-effective site assessment to help standardize and accelerate the evaluation of contaminated soils at sites are to provide a simple step-by-step methodology for environmental science/engineering professionals to calculate risk-based, site-specific soil levels for contaminants in soil. Its use may significantly reduce the time it takes to complete soil investigations and cleanup actions at some sites, as well as improve the consistency of these actions across the nation. To achieve the effective site assessment, it requires the criteria for choosing the type of standard and setting the magnitude of the standard come from different sources, depending on many factors including the nature of the contamination. A general scheme for site-specific assessment consists of sequential Phase I, II, and III, which is defined by workplan and soil screening levels. Phase I are conducted to identify and confirm a site's recognized environmental conditions resulting from past actions. If a Phase 1 identifies potential hazardous substances, a Phase II is usually conducted to confirm the absence, or presence and extent, of contamination. Phase II involve the collection and analysis of samples. And Phase III is to remediate the contaminated soils determined by Phase I and Phase II. However, important factors in determining whether a assessment standard is site-specific and suitable are (1) the spatial extent of the sampling and the size of the sample area; (2) the number of samples taken: (3) the strategy of taking samples: and (4) the way the data are analyzed. Although selected methods are recommended, application of quantitative methods is directed by users having prior training or experience for the dynamic site investigation process.

  • PDF

Long-term Monitoring Study of Soil Chemical Contents and Quality in Paddy Fields (논토양의 화학성과 질의 장기 변동)

  • Kim, M.S.;Kim, W.I.;Lee, J.S.;Lee, G.J.;Jo, G.L.;Ahn, M.S.;Choi, S.C.;Kim, H.J.;Kim, Y.S.;Choi, M.T.;Moon, Y.H.;Ahn, B.K.;Kim, H.W.;Seo, Y.J.;Lee, Y.H.;Hwang, J.J.;Kim, Y.H.;Ha, S.K.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.930-936
    • /
    • 2010
  • There is very important to investigate long-term trend of soil chemical properties and quality index for sustainable agriculture and production of agricultural safety products. Monitoring on soil chemical properties in paddy soils was conducted as one cycle with 4 years from 1999 to 2007. Paddy soil samples were taken from 4,007, 1,970, 2,070 sites in 1999, 2003 and 2007, respectively. With these data, soil quality index (SQI) was evaluated by method that Yoon et al suggested in 2004. Chemical properties of paddy soils were 5.8 for pH, 24 g $kg^{-1}$ for organic matter, 132 mg $kg^{-1}$ for available phosphate, 0.29 cmol_c\; kg-1 for exchangeable potassium, 4.7 $cmol_c\;kg^{-1}$ for exchangeable calcium, 1.3 $cmol_c\;kg^{-1}$ for exchangeable magnesium and 126 mg $kg^{-1}$ for available silicate in 2007. Long-term change was shown that pH has increased gradually whereas exchangeable potassium has decreased. However, reasonably large changes were found. Exchangeable calcium and available silicate level in 1999 was 4.0 $cmol_c\;kg^{-1}$, 86 mg $kg^{-1}$, but had risen to 4.7 $cmol_c\;kg^{-1}$, 126 mg $kg^{-1}$ in 2007, respectively. The change of paddy soils quality index was increased gradually and increasement of silicate quality index was higher than other quality indicators.

The Effect of Different Membranes on the Performance of Aqueous Organic Redox Flow Battery using Methyl Viologen and TEMPOL Redox Couple (다양한 멤브레인을 적용한 메틸 바이올로겐과 템폴 활물질 기반 수계 유기 레독스 흐름 전지 성능 평가)

  • Park, GyunHo;Lee, Wonmi;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.868-873
    • /
    • 2019
  • In this study, the evaluation of performance of AORFB using methyl viologen and TEMPOL as organic active materials in neutral supporting electrolyte (NaCl) with various membrane types was performed. Using methyl viologen and TEMPOL as active materials in neutral electrolyte solution, the cell voltage is 1.37V which is relatively high value for AORFB. Two types of membranes were examined for performance comparison. First, when using Nafion 117 membrane which is commercial cation exchange membrane, only the charge process occurred in the first cycle and the single cell couldn't work because of its high resistance. However, when using Fumasep anion exchange membrane (FAA-3-50) instead of Nafion 117 membrane, the result was obtained as the totally different charge-discharge graphs. When current density was $40mA{\cdot}cm^{-2}$ and cut off voltage range was from 0.55 V to 1.7 V, the charge efficiency (CE) was 97% and voltage efficiency (VE) was 78%. In addition, the discharge capacity was $1.44Ah{\cdot}L^{-1}$ which was 54% of theoretical capacity ($2.68Ah{\cdot}L^{-1}$) at $10^{th}$ cycle and the capacity loss rate was $0.0015Ah{\cdot}L^{-1}$ per cycle during 50 cycles. Through cyclic voltammetry test, it seems that this difference in the performance between the full cell using Nafion 117 membrane and Fumasep anion exchange membrane came from increasing resistance due to chemical reaction between membrane and active material, not the capacity loss due to cross-over of active material through membrane.