• Title/Summary/Keyword: 3상 DC/AC 인버터

Search Result 46, Processing Time 0.022 seconds

A Study on the Control and Drives of Three-Phase Buck-Boost DC-AC Inverter (3상 벅-부스트 DC-AC 인버터의 제어 및 구동에 관한 연구)

  • Han, Keun-Woo;Jung, Young-Gook;Lim, Young-Cheol;Oh, Seung-Yeol;Kim, Kwang-Heon
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.341-342
    • /
    • 2010
  • 본 논문에서는 종전의 3상 H-브리지 PWM 인버터와 다른 토폴로지를 갖는 3상 벅-부스트 DC-AC 인버터를 위한 제어 기법을 제안하였다. 이를 위하여 공간벡터 변조 방식(SVM : Space Vector Modulation) 및 PI 제어기를 벅-부스터 DC-AC 인버터에 적용하고 이를 PSIM 시뮬레이션 통하여 타당성을 검증하였다.

  • PDF

The Study of 3-Phase Bi-Directional DC to AC Inverter for the Bi-Model PV PCS (자립형 태양광 발전 시스템을 위한 3상 양방향 DC-AC 인버터 연구)

  • Yang, Seung-Dae;Jung, Seung-Hwan;Choi, Ju-Yeop;Choy, Ick;Lee, Young-Kwon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.319-324
    • /
    • 2012
  • This paper presents the study of 3-Phase bi-directional DC to AC inverter with unity power factor. 3-Phase bi-directional DC to AC inverter is important for the bi-modal PV PCS with an energy storage system. Both Inverting and converting are needed to connect between the grid side and boost converting side to charge and discharge the energy storage system. The paper proposes the appropriate circuit topology and proper control system for the bi-directional inverter. It also proposes the method of selecting the optimum control method considering system stability. PSIM simulation is used to validate the proposed algorithm.

  • PDF

The Improvement of Control Scheme for AC-DC-AC Converter Considering Input Voltage Unbalance (입력전원 불평형을 고려한 AC-DC-AC 컨버터 제어 특성 개선)

  • 현동석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.335-338
    • /
    • 2000
  • 최근에는 기존의 인버터시스템 전원으로 사용되던 다이오드정류기 또는 위상제어정류기의 단점을 개선하고 고속운전에 따르는 제어전압의 부족을 해결하기 위해 3상 PWM 컨버터의 사용이 증가하고 있는 추세이나 3상 PWM 컨버터의 제어는 입력전원이 평형일 경우를 전제로 하고 있다. 그러나 불평형전원은 실제 산업현장에서 빈번히 일어나는 현상으로 입력전원이 불평형이 되면 역상분전압에 의해 THD가 증가하고 직류링크전압에 저차 고조차성분이 나타나게 되므로 인버터의 성능에 악영향을 준다. 따라서 본 연구에서는 입력전원의 불평형에 따른 AC-DC-AC 컨버터의 문제점을 해결할 수 있는 효율적인 제어기법을 제시하는 것을 목적으로 하고 있다.

  • PDF

A Development of Solar Cell Silicon Ingot Glowing Converter System for 150[KW] 3[KA] (태양전지 실리콘 결정 성장용 150[KW] 3[KA] 컨버터 시스템 개발)

  • Park, Young-Sik;Kim, Min-Huei;Song, Hyun-Jig
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.237-238
    • /
    • 2012
  • 본 연구는 태양전지용 실리콘 결정 성장용으로 개발된 150[KW] 3,000[A]의 PWM 컨버터 시스템을 개발한 결과이다. 시스템의 구성은 3상 AC-DC 정류변환기, DC-AC 고주파 변환 단상 전파 브리지 PWM 인버터, AC-DC 변압기 중성점을 이용한 단상 전파정류기로 구성되어 있다. 입력 전압은 3상 460[V]이며, 출력은 직류 60[V], 3000[A]로 카본 저항 $2[m{\Omega}]$의 부하에 인버터의 고주파 변압기를 사용하여 스위칭 주파수가 15[KHz]로 PWM제어 방식에 의하여 전력을 제어한다.

  • PDF

Development of the Inverter System with UPS Function for the Air-Conditioning Blower (UPS 기능을 갖는 A/C Blower용 인버터 시스템 개발)

  • Lim, Seung-Beom;Lee, Yun-Ha;Mok, Hyung-Soo;Ji, Jun-Keun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.302-308
    • /
    • 2011
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations with AC 380V input. Therefore, the efficiency of the system is reduced and accoustic noise problem occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

Jeju 80kV HVDC Controller Modeling Using PSCAD/EMTDC Program (PSCAD/EMTDC 프로그램을 이용한 제주 80kV HVDC 제어기 모델링)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.533-541
    • /
    • 2011
  • This paper studies modeling of Jeju 80kV HVDC system and its controller by using PSCAD/EMTDC program. Reduced ac network is applied to verify interaction between ac network and dc system. Design parameter is applied to the converter transformer, harmonic filter and dc transmisstion line to simulate dc system. HVDC controller is divided into a rectifier controller and a inverter controller according to the converter operating mode. The inverter controller is composed of current control, voltage control and extingtion angle control. The rectifier controller is composed of current control and voltage control. Both controller has VDCOL characteristics so that current order is dependant on voltage variation. Step response, ac network single phase fault, three phase fault is simulated to verify the dynamic performance of controller model in both transient state and steady state.

Single-phase Control Algorithm of 4-Leg type PCS for Micro-grid System (마이크로그리드용 4-Leg 방식 PCS의 각상 개별제어 알고리즘에 관한 연구)

  • Kim, Seung-Ho;Choi, Sung-Sik;Kim, Seung-Jong;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.817-825
    • /
    • 2017
  • The AC-common bus microgrid system can overcome several weaknesses of the DC microgrid system by interconnecting the DC/AC inverters used for renewable energy with an AC network. Nevertheless, the unbalanced loads inherent in the electric power systems of island and small communities can deteriorate the performance of the AC microgrid system. This is because of the limited voltage regulation capability and mixed power flow in the voltage source inverter. In order to overcome the unbalanced load condition, this paper proposes a voltage and current control algorithm for the 4-leg inverter based on the single phase d-q control method, as well as the modeling of the voltage controller using Matlab/Simulink S/W. From the S/W simulation and experiment of the 250KW proto-type inverter, it is confirmed that the proposed algorithm is a useful tool for the design and operation of the AC microgrid system.

Spectral Analysis of DC Link Ripple Currents in Three-Phase AC/DC/AC PWM Converters (3상 AC/DC/AC PWM 컨버터의 직류링크 리플전류의 주파수 영역 해석)

  • 이동춘;박영욱;석줄기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.244-252
    • /
    • 2002
  • In this paper, do link ripple currents for three-phase ac/dc/ac PWM converters feeding adjustable speed ac machine drives are analysed in a frequency domain. The expression of the harmonic currents is developed by using switching functions of the converter and exponential courier series expansion. The effect of the displacement angle between the switching Periods of line-side converters and motor-side inverters on the dc link ripple currents is Investigated. Also, the influence of asynchronization of PWM is observed. The result of analysis is compared with frequency spectrum which results from PSIM simulation. The proposed analysis technique is useful to understand the principles of P% and to derive an equivalent model of the dc link capacitors in a high frequency range.

Design of Three-phase Buck-Boost DC-AC Inverter (3상 벅-부스트 DC-AC 인버터 설계)

  • Park, Jong-Gyu;Jang, Eun-Sung;Choi, Hyun-Chil;Shin, Hwi-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2396-2401
    • /
    • 2009
  • The three-phase buck-boost DC-AC inverter generates three alternating output voltages as the differential voltage of three DC-DC individual buck-boost converters. Three converters are driven with three DC-biased and 1200 phase-shifted sinusoidal references. The peak value of the inverter alternating output voltage can be larger or smaller than the value of the direct input voltage. In this paper, a three-phase buck-boost DC-AC inverter is designed and implemented on a prototype with digital controller using a microcontroller.

A Control Method and Test Results of Utility-Interactive Photovoltaic Power Generation Systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 황인호;안교상;임희천;김신섭
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2000
  • This paper desclibes a design method and test results of grid-connected photovoltaic power 당eneration s systems, which consists of solar cells, DCI AC inverter, utility grid. A 50 kW photovoltaic power generation s system including a 3-phase DCI AC inverter is designed and made in order to investigate the system l pelionnance for glid connection. Also the control scheme of a three phase cmrent-controlled PWM inverter W with PI controller is presented by using d-q transformation. The experimental waveforms show that the p proposed system has stable behavior with em unit power factor in utility-interactive operation.

  • PDF