• Title/Summary/Keyword: 2D Scaling

Search Result 217, Processing Time 0.029 seconds

Theoretical and practical features of J-scaled distortion-free HSQC

  • Cha, Jin Wook;Park, Sunghyouk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Employing of 13C stable-isotopes in NMR metabolomics can give unique splitting patterns and coupling constants information originated from 13C-13C coupling interaction that provide an important structural information regarding the cellular metabolic process. But it has been known that an undesirable signal distortion in 2D heteronuclear correlation study, due to 13C-13C interaction, hampers an analysis of the coupling information. Recently, we proposed J-scaled distortion-free heteronuclear single-quantum coherence (HSQC) sequence which provides a distortion-free 13C-13C coupling information with a selective resolution enhancement of JCC splitting. In this paper, we dicuss theoretical aspect and practical feature of J-scaled HSQC pulse sequence. The conceptual explanation of orgin of the signal distortion by 13C-13C coupling interaction and design of J-scaled HSQC through exemplified results are provided in brief.

Analysis of the Relative Efficiency and Competitiveness of Production Structure for the Industrial Clusters in Korea (국내 주요 산영클러스더별 상대적 효율성 분석 및 생산구조 비교)

  • Park, Chu-Hwan
    • Journal of the Korean Academic Society of Industrial Cluster
    • /
    • v.2 no.1
    • /
    • pp.44-60
    • /
    • 2008
  • This paper analyses the relative efficiency and competitiveness of production structure for the industrial clusters(Ulsan, Changwon, Kumi, Wonjoo, Banwol & Siwha, Kwangwju, Gunsan) which had allocated in 2004 in Korea by the DEA approaches. The results show that except U1san, Wonjoo, the 5 industrial clusters have improved the relative efficiency in terms of input and output since they were allocated. And, the reason of the inefficiency for the 5 industrial clusters were not for the technical relationship but for the production scaling size. That is, by clustering for the industrial production firms, the economic effect came true throughout the production scaling size effects. Also, by the positioning approach for the production factors such as labor, capital, and R&D investment via production growth, the results show that Banwol & Siwha, Goomi clusters have effectively been managed, but Wonjoo, U1san and Gunsan are not.

  • PDF

Design and Applications of Graphics Interface on Personal Computer (개인용 컴퓨터상의 그래픽스 인터페이스 설계와 응용)

  • Kim, Jin-Han;Kyung, Chong-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.1
    • /
    • pp.113-121
    • /
    • 1989
  • A software interface called CGI-K including device driver routines and graphics primitives for the grphic board "K" was designed, implemented in the Design Automation Laboratory of KAIST and installed on IBM PC/AT, using assembly and C language supported by TMS 34010 grphics processor. Several algorithms generating the graphics primitives such as box, circle, pie chord are proposed. The drawing speed of CGI-K on the graphic board K was found out to be three to ten times faster than that of the EGA for several examples. A 2-D graphics editor called GRIM (graphics input and modification) and a 3-dimensional graphics renderer called IPCHE which can draw 3-D objects were developed as two major application programs running on CGI-K. The graphics primitives supported in GRIM include polygon, box, circle, and ace. The IPCHE receives a 3-D objects data file and displays the 3-D object on the screen with hidden surface removal, shading, and perspective scaling.

  • PDF

Calibration Technique for Freehand 3-D Ultrasound System (3차원 초음파 시스템의 캘리브레이션 방법)

  • Hwang, Myun Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6066-6071
    • /
    • 2013
  • This paper proposes a calibration method for a freehand 3-D ultrasound system in medical robotic research. The calibration block with six wires was designed to set the fixed target points. The positions of the ultrasound probe and calibration block were measured using an optical tracker. The relationship between the position of the ultrasound probe and the pixel coordinates in the images was derived using a calibration process. The scaling matrix was also calculated. The experimental results showed that the proposed method could find solutions using a simple least square method from one or multiple ultrasound images.

Extraction or gaze point on display based on EOG for general paralysis patient (전신마비 환자를 위한 EOG 기반 디스플레이 상의 응시 좌표 산출)

  • Lee, D.H.;Yu, J.H.;Kim, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.87-93
    • /
    • 2011
  • This paper proposes a method for extraction of the gaze point on display using EOG(Electrooculography) signal. Based on the linear property of EOG signal, the proposed method corrects scaling difference, rotation difference and origin difference between coordinate of using EOG signal and coordinate on display, without adjustment using the head movement. The performance of the proposed method was evaluated by measuring the difference between extracted gaze point and displayed circle point on the monitor with 1680*1050 resolution. Experimental results show that the average distance errors at the gaze points are 3%(56pixel) on x-axis, 4%(47pixel) on y-axis, respectively. This method can be used to human computer interface of pointing device for general paralysis patients or HCI for VR game application.

Genetic Analysis on Germination Rate and Fat Acidity of Japonica Rice Seeds after High Temperature Storage

  • Noh, Gwang-Il;Kim, Ki-Young;Shin, Seo-Ho;Park, Hyun-Su;Kim, Bo-Kyeong;Shin, Mun-Sik;Ko, Jae-Kwon
    • Korean Journal of Breeding Science
    • /
    • v.40 no.3
    • /
    • pp.228-233
    • /
    • 2008
  • This study was carried out to get the genetic information on the germination rate and fat acidity after 12 weeks' storage at $35^{\circ}C$. Germination rate decreased with longer storage period, while fat acidity increased. Germination rate was higher in the order of Koshihikari, Hanmaeum and Unkwangbyeo after 12 weeks' storage at $35^{\circ}C$. Fat acidity of Koshihikari and Hanmaeum was gradually increased, but that of Unkwangbyeo was dramatically increased after 4 weeks' storage at $35^{\circ}C$. The genetic mode on germination rate and fat acidity using the joint scaling test was shown to be additive-dominance gene effects. Additive([d]) effect was higher than dominance effect([h]) in all crosses. The average degree of dominance, [h]/[d], was less than 1, indicating that germination rate and fat acidity was partially dominant. Germination rate and fat acidity based on frequency distribution of 2 crosses were quantitative characters expressed by polygenes.

Choline chloride-Glycerol (1:2 mol) as draw solution in forward osmosis for dewatering purpose

  • Dutta, Supritam;Dave, Pragnesh;Nath, Kaushik
    • Membrane and Water Treatment
    • /
    • v.13 no.2
    • /
    • pp.63-72
    • /
    • 2022
  • Choline chloride-glycerol (1:2 mol), a natural deep eutectic solvent (NADES) is examined as a draw solution in forward osmosis (FO) for dewatering application. The NADES is easy to prepare, low in toxicity and environmentally benign. A polyamide thin film composite membrane was used. Characterization of the membrane confirmed porous membrane structure with good hydrophilicity and a low structural parameter (722 ㎛) suitable for FO application. A dilute solution of 20% (v/v) NADES was enough to generate moderate water flux (14.98 L m-2h-1) with relatively low reverse solute flux (0.125 g m-2h-1) with deionized water feed. Application in dewatering industrial wastewater feed showed reasonably good water flux (11.9 L m-2h-1) which could be maintained by controlling the external concentration polarization and fouling/scaling mitigation via simple periodic deionized water wash. In another application, clarified sugarcane juice could be successfully concentrated. Recovery of the draw solute was accomplished easily by chilling utilizing thermo responsive phase transition property of NADES. This study established that low concentration NADES can be a viable alternative as a draw solute for dewatering of wastewater and other heat sensitive applications along with a simple recovery process.

Vitamin D Level in Blood of Menopausal Women over 50 and the Relation with the Proportion Requiring Dental Scaling (50세 이상 폐경여성의 혈중 비타민 D 농도와 치면세마필요자율의 관련성)

  • Lee, Sun Hee;Roh, Sang Chul
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.393-402
    • /
    • 2013
  • The purpose of this study was to examine the relationship between vitamin D and periodontal diseases based on the raw data of the 5th National Health & Nutrition Examination Survey of 2010. The subjects in this study were 1,327 people, and those whose data on major variables were missing and who suffered from diabetes and/or osteoporosis were excluded. As for data analysis, R2.15.1 program and PASW Statistics 18.0 were utilized. The findings of the study were as follows: 1. As for all the respondents aged 50 and up, there was no significant relationship between vitamin D and periodontal diseases. 2. As for the post-menopausal women including the women who underwent bilateral ovariectomy, the vitamin D-deficit group 1 (<10) were 6.66-fold more likely to suffer from periodontal diseases than the vitamin D-sufficient group (${\geq}30$) (OR, 6.66; 95% CI, 1.004~44.19). The above-mentioned findings ascertained that vitamin D had a significant negative correlation to periodontal diseases among the post-menopausal women including the women who underwent bilateral ovariectomy. This finding should be taken into account in terms of the prevention and management of periodontal diseases.

Design of Low-Power and Low-Latency 256-Radix Crossbar Switch Using Hyper-X Network Topology

  • Baek, Seung-Heon;Jung, Sung-Youb;Kim, Jaeha
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.1
    • /
    • pp.77-84
    • /
    • 2015
  • This paper presents the design of a low-power, low area 256-radix 16-bit crossbar switch employing a 2D Hyper-X network topology. The Hyper-X crossbar switch realizes the high radix of 256 by hierarchically combining a set of 4-radix sub-switches and applies three modifications to the basic Hyper-X topology in order to mitigate the adverse scaling of power consumption and propagation delay with the increasing radix. For instance, by restricting the directions in which signals can be routed, by restricting the ports to which signals can be connected, and by replacing the column-wise routes with diagonal routes, the fanout of each circuit node can be substantially reduced from 256 to 4~8. The proposed 256-radix, 16-bit crossbar switch is designed in a 65 nm CMOS and occupies the total area of $0.93{\times}1.25mm^2$. The simulated worst-case delay and power dissipation are 641 ps and 13.01 W when operating at a 1.2 V supply and 1 GHz frequency. In comparison with the state-of-the-art designs, the proposed crossbar switch design achieves the best energy-delay efficiency of $2.203cycle/ns{\cdot}fJ{\cdot}{\lambda}2$.

A 2-Gb/s SLVS Transmitter for MIPI D-PHY (MIPI D-PHY를 위한 2-Gb/s SLVS 송신단)

  • Baek, Seung Wuk;Jeong, Dong Gil;Park, Sang Min;Hwang, Yu Jeong;Jang, Young Chan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.25-32
    • /
    • 2013
  • A 1.8V 2-Gb/s scalable low voltage signaling (SLVS) transmitter (TX) is designed for mobile applications requiring high speed and low power consumption. It consists of 4-lane TX for data transmission, 1-lane TX for a source synchronous clocking, and a 8-phase clock generator. The proposed SLVS TX has the scaling voltage swing from 50 mV to 650 mV and supports a high speed (HS) mode and a low power (LP) mode. An output impedance calibration scheme for the SVLS TX is proposed to improve the signal integrity. The proposed SLVS TX is implemented by using a 0.18-${\mu}m$ 1-poly 6-metal CMOS with a 1.8 V supply. The simulated data jitter of the implemented SLVS TX is about 8.04 ps at the data rate of 2-Gb/s. The area and power consumption of the 1-lane of the proposed SLVS TX are $422{\times}474{\mu}m^2$ and 5.35 mW/Gb/s, respectively.