• 제목/요약/키워드: 2.5Vpp

검색결과 42건 처리시간 0.026초

A 1.8 V 40-MS/sec 10-bit 0.18-㎛ CMOS Pipelined ADC using a Bootstrapped Switch with Constant Resistance

  • Eo, Ji-Hun;Kim, Sang-Hun;Kim, Mun-Gyu;Jang, Young-Chan
    • Journal of information and communication convergence engineering
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2012
  • A 40-MS/sec 10-bit pipelined analog to digital converter (ADC) with a 1.2 Vpp differential input signal is proposed. The implemented pipelined ADC consists of eight stages of 1.5 bit/stage, one stage of 2 bit/stage, a digital error correction block, band-gap reference circuit & reference driver, and clock generator. The 1.5 bit/stage consists of a sub-ADC, digital to analog (DAC), and gain stage, and the 2.0 bit/stage consists of only a 2-bit sub-ADC. A bootstrapped switch with a constant resistance is proposed to improve the linearity of the input switch. It reduces the maximum VGS variation of the conventional bootstrapped switch by 67%. The proposed bootstrapped switch is used in the first 1.5 bit/stage instead of a sample-hold amplifier (SHA). This results in the reduction of the hardware and power consumption. It also increases the input bandwidth and dynamic performance. A reference voltage for the ADC is driven by using an on-chip reference driver without an external reference. A digital error correction with a redundancy is also used to compensate for analog noise such as an input offset voltage of a comparator and a gain error of a gain stage. The proposed pipelined ADC is implemented by using a 0.18-${\mu}m$ 1- poly 5-metal CMOS process with a 1.8 V supply. The total area including a power decoupling capacitor and the power consumption are 0.95 $mm^2$ and 51.5 mW, respectively. The signal-to-noise and distortion ratio (SNDR) is 56.15 dB at the Nyquist frequency, resulting in an effective number of bits (ENOB) of 9.03 bits.

다공질 실리콘 구조를 이용한 화학 및 바이오 센서 (Porous silicon-based chemical and biosensors)

  • 김윤호;박은진;최우석;홍석인;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2410-2412
    • /
    • 2005
  • In this study, two types of PS substrate were fabricated for sensing of chemical and biological substances. For sensing of the humidity and chemical analyzes such as $CH_3OH$ or $C_2H_5OH$, PS layers are prepared by photoelectrochemical etching of silicon wafer in aqueous hydrofluoric acid solution. To evaluate their sensitivity, we measured the resistance variation of the PS diaphragm. As the amplitude of applied voltage increases from 2 to 6Vpp at constant frequency of 5kHz, the resistance variation for humidity sensor rises from 376.3 to $784.8{\Omega}$/%RH. And the sensitivities for $CH_3OH$ and $C_2H_5OH$ were 0.068 uA/% and 0.212 uA/%, respectively. For biological sensing application, amperometric urea sensors were fabricated based on porous silicon(PS), and planar silicon(PLS) electrode substrates by the electrochemical methods. Pt thin film was sputtered on these substrates which were previously formed by electrochemical anodization. Poly (3-methylthiophene) (P3MT) were used for electron transfer matrix between urease(Urs) and the electrode phase, and Urs also was by electrochemically immobilized. Effective working area of these electrodes was determined for the first time by using $Fe(CN)_6^{3-}/Fe(CN)_6^{4-}$ redox couple in which nearly reversible cyclic voltammograms were obtained. The $i_p$ vs $v^{1/2}$ plots show that effective working electrode area of the PS-based Pt thin film electrode was 1.6 times larger than the PLS-based one and we can readily expect the enlarged surface area of PS electrode would result in increased sensitivity by ca. 1.6 times. Actually, amperometric sensitivity of the Urs/P3MT/Pt/PS electrode was ca 0.91uA/$mM{\cdot}cm^2$, and that of the Urs/P3MT/Pt/PLS electrode was ca. 0.91uA/$mM{\cdot}cm^2$ in a linear range of 1mmol/L to 100mmol/L urea concentrations

  • PDF

주파수 튜닝이 가능한 진동형 에너지 하베스터에 관한 연구 (A Study on Frequency Tunable Vibration Energy Harvester)

  • 이병철;정귀상
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.202-206
    • /
    • 2014
  • The common vibration energy harvester effectively converts mechanical vibration to electric power at a specific resonance frequency that must match the ambient excitation frequency. The resonance frequencies of energy harvesters are fixed during the design process and could not be changed after fabrication. In this paper, we proposed the new frequency tuning which uses the rotatable spring in order to adjust the spring constants. By this tuning method, the resonance frequency of the system can simply be manipulated using spring rotation. The proposed energy harvester has been successfully tuned to a resonance frequency between 23 and 32 Hz. The experimental results demonstrated that the proposed energy harvester could generate a maximum output power of $60{\mu}W$ with an acceleration of 0.5 g ($1g=9.81m/s^2$), and that the resonance frequency of the harvester was able to tune approximately 31.4%. When the proposed harvester was attached to an automobile engine, the maximum open circuit voltage of 1.78 Vpp was produced at 700 rpm.

수정된 라플라시안 센서를 이용한 심박변이도 측정에 관한 연구 (A Study on the Measurement of Heart Rate Variability using the Modified Laplacian Electrodes)

  • 이충근;신항식;김홍래;이정환;김용준;이명호
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.1050-1056
    • /
    • 2009
  • Heart Rate Variability(HRV) is a parameter that represents monitoring variability of time intervals between R-peak in electrocardiography. HRV serves to various applications, such as indices of autonomic functions, prediction of cardiac sudden death, assessment of stress and emotional, etc. However, as measuring R-peak in ECG needs at least 3-electrodes, and it is inconvenient for end users. In this paper, we suggested the modified laplacian electrodes for measuring HRV at one-point, which are producted by MEMS fabrication and have the two circular electrodes on the pad. For optimal position and direction, we performed an experiment that compared with pearson correlation coefficient and the amplitude of signals, between standard lead II and proposed electrodes. We analyzed the HRV parameters, such as standard deviation of the NN interval(SDNN), high frequency(HF), low frequency(LF), LF/HF ratio. The result showed that the average correlation coefficient and amplitude are 0.967 and 0.685 mVpp at the position 2. The coeffiecient correlation between the standard HRV and proposed electrode-HRV is 0.999

Auto Focusing 및 Optical zooming에 사용될 초음파모터의 특성분석 (Characteristics Analysis and Fabrication of an Ultrasonic Motor for Auto Focusing and Optical zooming)

  • 윤용진;권오덕;이종섭;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.330-331
    • /
    • 2005
  • 본 논문에서는 카메라폰용 광학중(Optical zooming) 과 자동초점조절장치 (Auto Focusing, AF)에 쓰일 초음파모터를 제작하였다. 초음파모터의제작 및 시뮬레이션은 유한요소해석 프로그램인 ATILA 5.2.1 (Magsoft co.)를 사용하여 디자인설계에 따른 구동특성을 고찰하였고 제작된 초음파모터는 한쪽 면이 없는 사작형의 탄성체를 제작하였으며 탄성체의 양쪽 다리에 각각 압전체를 부착하였다. 또한 압전세라믹의 조성은 $0.9Pb(Zr_{0.51}Ti_{0.49})O_3-0.1Pb(Mn_{1/3}Nb_{1/3}Sb_{1/3})O_3$의 조성으로 설계하였고 시편의 제조는 7-layer로 적층하였다. 제작된 압전세라믹의 치수는 6*2*0.35$mm^3$(길이*폭*두께)로 제작하였다 또한 탄성체의 외형치수는 10*10*2$mm^3$로 제작하였으며 두께를 각각 0.3[mm], 0.5[mm], 0.8[mm]으로 변화시키며 제작하였다. 두께가 0.8[mm]인경우 공진주파수는 60.5[kHz]를 나타내었으며 초음파모터의 압전세라믹에 인가전압이 증가함에 따라 회전속도와 모터에 흐르는 전류는 증가하였다. 인가전압이 40[Vpp] 일 때 회전속도는 206[rpm] 이며 소비전력은 0.3[W]로 제작된 시편은 카메라폰용 광학중 및 자동초점조절장치시스템 분야에 응용이 가능하다.

  • PDF

제한병기 소세포폐암에서 흉부 방사선 치료의 도입 시기에 따른 치료 효과의 비교 분석 (The effects according to the timing of thoracic radiotherapy in limited stage small cell lung cancer)

  • 박상기;김근화;정성수;신경상;김애경;조해정;서지원;김재성;조문준;김주옥;김선영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권6호
    • /
    • pp.903-915
    • /
    • 1996
  • Background: Combination chemotherapy is now considered to be the cornerstone of small cell lung cancer (SCLC). management but the optimal management of limited SCLC is not well defined. The role of thoracic radiotherapy (TRT) is less well established. Recent meta-analyses reports revealed that TRT combined with chemotherapy produce "good" local control and prolonged survival. But other reports that survival was not changed. The liming, dose, volume and fractionation for TRT with the combined chemotherapy of SCLC remains unsettled. In this study, we analyzed the effects according to the timing of thoracic radiotherapy in limited SCLC. Method: All fifty one patients received cytoxan, adriamycin and vincristine(CAV) alternating with etoposide and cisplatin(VPP) every 3 weeks for 6 cycles were randomized prospectively into two groups: concurrent and sequential. 27 patients received 4500cGy in 30 fractions(twice daily 150cGy fractional dose) over 3 weeks 10 the primary site concurrent with the first cycle of VPP(concurrent gorup). 24 patients received 4000 to 5000cGy over 5 or 6 weeks after completion of sixth cycles of chemotherapy(sequential group). Results: 1. Response rates and response duration : Response rates were not significantly different between two groups(p=0.13). But response duration was superior in the concurrent group(p=0.03). 2. Survival duration was nor different between two groups(p=0.33). 3. Local control rate was superior in the concurrent group(p=0.00). 4. Side effects and toxicities: Hematologic toxicities, especially leukopenia, infection and frequency of radiation esophagitis were higher in the concurrent group (p=0.00, 0.03, 0.03). Conclusion: The concurrent use of TRT with chemotherapy failed to improve the survival of limited stage SCLC patients compared with the sequential use of TRT but response duration and local control rate were superior in the concurrent group. Frequency of radiation esophagitis, life threatening hematologic toxicities and infection were more frequent in the concurrent group than sequential group. So, the selection of an optimal schedule of chemotherapy combined with TRT that would lead to a major increase in survival with minimal toxicity is remained to be validated in large scale study in the future.

  • PDF

Non-contact Transportation of Flat Panel Substrate by Combined Ultrasonic Acoustic Viscous and Aerostatic Forces

  • Isobe, Hiromi;Fushimi, Masaaki;Ootsuka, Masami;Kyusojin, Akira
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.44-48
    • /
    • 2007
  • In recent years, the size of plane substrates and semiconductor wafers has increased. As conventional contact transportation systems composed of, for example, carrier rollers, belt conveyers, and robot hands carry these longer and wider substrates, the increased weight results in increased potential for fracture. A noncontact transportation system is required to solve this problem. We propose a new noncontact transportation system combining acoustic viscous and aerostatic forces to provide damage-free transport. In this system, substrates are supported by aerostatic force and transported by acoustic viscous streaming induced by traveling wave deformation of a disk-type stator. A ring-type piezoelectric transducer bonded on the stator excites vibration. A stator with a high Q piezoelectric transducer can generate traveling vibrations with amplitude of $3.2{\mu}m$. Prior to constructing a carrying road for substrates, we clarified the basic properties of this technique and stator vibration characteristics experimentally. We constructed the experimental equipment using a rotational disk with a 95-mm diameter. Electric power was 70 W at an input voltage of 200 Vpp. A rotational torque of $8.5\times10^{-5}Nm$ was obtained when clearance between the stator and disk was $120{\mu}m$. Finally, we constructed a noncontact transport apparatus for polycrystalline silicon wafers $(150(W)\times150(L)\times0.3(t))$, producing a carrying speed of 59.2 mm/s at a clearance of 0.3 mm between the stator and wafer. The carrying force when four stators acted on the wafer was $2\times10^{-3}N$. Thus, the new noncontact transportation system was demonstrated to be effective.

콘 칼로리미터와 TGA를 이용한 할로겐 계통의 난연제를 첨가한 폴리프로필렌 수지의 난연성 및 열 안정성에 관한 연구 (Fire Resistance and Thermal Stability Study of Fire-Retarded Polypropylene Systems by Using Cone Calorimeter and Thermogravimetry)

  • 곽성복;정찬화;남재도;김준형;최미애
    • 폴리머
    • /
    • 제24권6호
    • /
    • pp.777-786
    • /
    • 2000
  • 본 연구에서는 범용 열가소성 수지인 폴리프로필렌 (virgin polypropylene, VPP)과 폴리프로필렌을 주성분으로 하는 재생플라스틱의 난연성을 향상시키기 위하여, 난연제 decabromodiphenyl oxide (DBDPO)와 chlorinated paraffin wax (CPW)를 혼합하여 이것들의 난연 특성을 정량적으로 비교 분석 연구하였다. 난연성 평가 측정으로 콘 칼로리미터 (cone calorimeter, ASTM E1354, ISO 5660), 한계산소지수 측정 (LOI, ASTM D2863, ISO 4589) 등을 사용하였고, 콘 칼로리미터를 이용하여 DBDPO와 CPW의 난연효율을 정량적으로 측정하였다. 콘 칼로리미터의 결과로 난연제의 난연효율을 측정한 결과, DBDPO가 CPW보다는 약 2배의 난연효율을 가지고 있다는 것을 확인하였고, 한계산소지수 측정 결과와 유사한 난연효율을 보임을 확인하였다. 열중량 분석 (TGA) 측정결과 난연제 DBDPO를 첨가하였을 때 약 30~5$0^{\circ}C$의 열분해 온도의 상승을 확인할 수 있었다.

  • PDF

Fabrication of Piezoelectric Micro Bending Actuators Using Sol-Gel Thick PZT films

  • Park, Joon-Shik;Yang, Seong-Jun;Park, Kwang-Bum;Yoon, Dae-Won;Park, Hyo-Derk;Kang, Sung-Goon;Lee, Nak-Kyu;Na, Kyoung-Hoan
    • 반도체디스플레이기술학회지
    • /
    • 제3권3호
    • /
    • pp.1-4
    • /
    • 2004
  • Fabrication and electrical and mechanical properties of piezoelectric micro bending actuators (PMBA) using sol-gel-multi-coated thick PZT films and MEMS processes were investigated. PMBA could be used for design and fabrication of micro fluidic devices, for example, micro-pumps, micro dispensers, and so on. PMBA were fabricated using 2 um thick PZT films on Pt (350 nm)/$SiO_2$ (500 nm)/Si ($300\mu\textrm{m}$) substrates and MEMS processes. 7 types of PMBA were fabricated with areas of silicon diaphragms, PZT films and top electrodes. When the sizes of silicon diaphragms, PZT films and Pt top electrodes were reduced from 3000$\times$$1389\mu\textrm{m}$, 4000$\times$$1000\mu\textrm{m}$ and 4000$\times$$900\mu\textrm{m}$ down to 14%, 14% and 11 % of them, respectively, the center displacements of PMBA were decreased from 0.68 um to 0.10 um at 5 Hz and 12 Vpp. So, PMBA with large areas showed larger displacements than PMBA with small areas and experimental results were also good agreement with the plate and shell theory.

  • PDF

입력전압범위 감지회로를 이용한 6비트 250MS/s CMOS A/D 변환기 설계 (Design of a 6bit 250MS/s CMOS A/D Converter using Input Voltage Range Detector)

  • 김원;선종국;정학진;박리민;윤광섭
    • 대한전자공학회논문지SD
    • /
    • 제47권5호
    • /
    • pp.16-23
    • /
    • 2010
  • 본 논문에서는 무선통신시스템의 수신단에 적용될 수 있는 6비트 250MS/s 플래쉬 A/D 변환기를 설계하였다. 제안하는 플래쉬 A/D 변환기는 기준 저항열에 입력전압범위 감지회로를 사용하여 비교기에서 소모하는 동적소비전력을 최소화 되게 설계하였다. 기존 플래시 A/D 변환기보다 아날로그단 소비전력은 4.3% 증가한 반면에, 디지털단 소비전력은 1/7로 감소하여 전체 소비전력은 1/2 정도로 감소하였다. 설계된 A/D 변환기는$0.18{\mu}m$ CMOS 1-poly 6-metal 공정으로 제작되었으며 측정 결과 입력 범위 0.8Vpp, 1.8V의 전원 전압에서 106mW의 전력소모를 나타내었다. 250MS/s의 변환속도와 30.27MHz의 입력주파수에서 4.1비트의 유효비트수를 나타내었다.