• 제목/요약/키워드: 2-phase calibration

검색결과 357건 처리시간 0.025초

A Clock and Data Recovery Circuit with Adaptive Loop Bandwidth Calibration and Idle Power Saved Frequency Acquisition

  • Lee, Won-Young;Jung, Chae Young;Cho, Ara
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권4호
    • /
    • pp.568-576
    • /
    • 2017
  • This paper presents a clock and data recovery circuit with an adaptive loop bandwidth calibration scheme and the idle power saved frequency acquisition. The loop bandwidth calibration adaptively controls injection currents of the main loop with a trimmable bandgap reference circuit and trains the VCO to operate in the linear frequency control range. For stand-by power reduction of the phase detector, a clock gating circuit blocks 8-phase clock signals from the VCO and cuts off the current paths of current mode D-flip flops and latches during the frequency acquisition. 77.96% reduction has been accomplished in idle power consumption of the phase detector. In the jitter experiment, the proposed scheme reduces the jitter tolerance variation from 0.45-UI to 0.2-UI at 1-MHz as compared with the conventional circuit.

DRAM bus system을 위한 analog calibration 적용 Pre-emphasis Transmitter

  • 박정준;차수호;유창식;기중식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.653-654
    • /
    • 2006
  • A Pre-emphasis transmitter for DRAM bus system has achieved 3.2Gbps/pin operation at 1.8V supply voltage with 0.18um CMOS process. The transmitter has 800MHz PLL to generate 4 phase clocks. The 4 phase clocks are used for input clock of PRBS and multiplexing. One tap pre-emphasis is used to reduce inter symbol interference (ISI) caused by channel low pass effects. The analog calibration makes the optimized driver impedance independent with the PVT variation.

  • PDF

Determination of Fluorescent Whitening Agents in Paper Materials by Ion-Pair Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Jeong Soo;Kim, Do Hwan;Kim, Keon
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권12호
    • /
    • pp.3971-3976
    • /
    • 2012
  • A simple method was developed for the analysis of seven stilbene-type fluorescent whitening agents (FWAs) in paper materials by ion-pair reversed-phase high-performance liquid chromatography with fluorescence detection. These stilbene-type FWAs included two disulfonate, two tetrasulfonate, and three hexasulfonate compounds. After optimization of chromatographic conditions, the FWAs were satisfactorily separated using a reversed-phase column (RP-18) with the following isocratic mobile phase: methanol-water (60:40) containing 17.5 mM TBABr and 10 mM citrate buffer (pH = 7.0). The calibration plot was linear in the range from 5 to 500 ng/mL for two disulfo-FWAs and from 1 to 500 ng/mL for the other five FWAs. Precision levels of the calibration curve as indicated by RSD of response factors were 1.2 and 8.1%. Limits of quantitation (LOQ) ranged from 1.2 to 11 ng/mL.

Precise Test Sieves Calibration Method Based on Off-axis Digital Holography

  • Abdelsalam, Dahi Ghareab;Baek, Byung-Joon;Kim, Dae-Suk
    • Journal of the Optical Society of Korea
    • /
    • 제15권2호
    • /
    • pp.146-151
    • /
    • 2011
  • We describe, throughout a Mach-Zehnder interferometric configuration, a new test sieves calibration method based on off-axis digital holography. The experiment is conducted on a test sieve of square openings. The nominal sieve opening is 1.00 mm with maximum individual opening of 1.14 mm in size. The recorded off-axis hologram is numerically processed using Fresnel transforms to obtain an object wave (amplitude and phase). From the reconstructed phase, the average size of the illuminated openings has been measured precisely. The proposed method can provide a real time solution for calibrating test sieves very precisely and with moderate accuracy.

고정밀 회전엔코더를 이용한 회전진동 교정시스템 (Calibration System for Angular Vibration Using Precision Rotary Encoder)

  • 남승환;백경민;정완섭
    • 한국음향학회지
    • /
    • 제33권1호
    • /
    • pp.31-39
    • /
    • 2014
  • 본 논문은 고정밀 회전엔코더를 이용한 회전진동 교정시스템의 실현방안을 제안한다. 제안된 시스템과 비교를 위해 한국표준과학연구원의 회전진동 절대교정시스템을 소개하며 회전진동 센서의 교정을 위한 장치와 측정 불확도 모델을 각각 제시한다. 제안된 방법은 회전엔코더의 교정방법에 따라 두 가지 로 나뉘는데 첫 번째는 레이저 간섭계를 이용하여 교정된 엔코더를 사용하는 방법이고, 두 번째는 제조사가 제공하는 성적서를 이용하여 교정 불확도를 평가하는 방법이다. 0.4 ~ 200 Hz의 교정주파수 구간에서 각가속도계를 교정한 결과, 첫 번째 제안된 방법은 절대교정시스템을 기준으로 감도 차이가 0.1 % 그리고 위상 차이는 $0.01^{\circ}$이내였으며 최대 확장불확도 진폭은 0.6 % 그리고 위상은 $0.4^{\circ}$ 이었다. 두 번째 제안된 방법은 절대교정시스템을 기준으로 감도차이가 진폭은 0.1 % 그리고 위상차이는 $0.6^{\circ}$ 이내였으며 최대 확장불확도는 진폭 4.8 % 와 위상 $2.8^{\circ}$이었다.

Evaluation of Phase Calibration Performance with KVN

  • Jung, Dawoon;Sohn, Young-Jong;Byun, Do-Young;Jung, Taehyun
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.36.2-36.2
    • /
    • 2016
  • In mm-VLBI, the quality of observation data is largely affected by atmospheric effect. The most challenging matter is that the phase of correlator output fluctuates rapidly resulting from a variation of atmospheric propagation delay. Consequently, it is demanding to achieve high Signal-to-Noise ratio by integrating data in time domain before calibrating atmospheric delay. However, Korean VLBI Network (KVN) has a unique system to make a 4-frequency (22/43/86/129 GHz) simultaneous observation in mm-wavelength and Frequency Phase Transfer (FPT) calibration technique has effectively removed atmospheric delay in the simultaneous multi-frequency observation of the KVN. For astrometric and astrophysical studies, we evaluated the FPT performance of KVN in various observing conditions. Using the total 38 bright AGNs, we have compared atmospheric conditions such as ground-based weather information, system temperature, atmospheric delay with the calibration results of FPT at 22/43/86/129 GHz during the five experiments in 2013, and quantified its performance in terms of coherence function and Allan variance. We present the analysis result of the relation between the FPT performance and observing conditions.

  • PDF

Joint Estimation of Near-Field Source Parameters and Array Response

  • Cui, Han;Peng, Wenjuan
    • Journal of Information Processing Systems
    • /
    • 제13권1호
    • /
    • pp.83-94
    • /
    • 2017
  • Near-field source localization algorithms are very sensitive to sensor gain/phase response errors, and so it is important to calibrate the errors. We took into consideration the uniform linear array and are proposing a blind calibration algorithm that can estimate the directions-of-arrival and range parameters of incident signals and sensor gain/phase responses jointly, without the need for any reference source. They are estimated separately by using an iterative approach, but without the need for good initial guesses. The ambiguities in the estimations of 2-D electric angles and sensor gain/phase responses are also analyzed in this paper. We show that the ambiguities can be remedied by assuming that two sensor phase responses of the array have been previously calibrated. The behavior of the proposed method is illustrated through simulation experiments. The simulation results show that the convergent rate is fast and that the convergent precision is high.

T-DMB/DAB/FM 수신기를 위한 광대역 델타시그마 분수분주형 주파수합성기 (A Wideband ${\Delta}{\Sigma}$ Frequency Synthesizer for T-DMB/DAB/FM Applications in $0.13{\mu}m$ CMOS)

  • 신재욱;신현철
    • 대한전자공학회논문지SD
    • /
    • 제47권12호
    • /
    • pp.75-82
    • /
    • 2010
  • 본 논문은 다중대역 송수신기 CMOS RFIC 단일 칩을 위한 광대역 델타시그마 분수분주형 주파수합성기에 관한 것이다. 광대역 VCO의 LC Tank에 6-bit Switched Capacitor Array Bank를 작용하여 2340~3940 MHz의 출력주파수 범위를 가지도록 하였으며, 위상동기 전 Capacitor Bank Code를 선택하기위한 VCO Frequency Calibration 회로는 전체 주파수대역에서 $2{\mu}s$이하로 보정을 마치는 뛰어난 성능을 보여준다. 광대역 VCO로부터 T-DMB/DAB/FM Radio의 LO 신호를 생성하기 위해 선택 가능한 다중분주비 ${\div}2$, ${\div}16$, ${\div}32$를 가지는 LO 신호 발생기는 L-Band (1173 ~ 1973 MHz), VHF-III (147 ~ 246 MHz), VFH-II (74~123 MHz)에서 I/Q신호를 생성한다. Integrated Phase Noise는 전체 대역에서 0.8 degree RMS 이하로 측정되어 매우 낮은 위상잡음을 보여주었다. 또한, VCO Frequency Calibration 시간을 포함하는 주파수합성기의 전체 동기시간은 $50{\mu}s$ 이하로 측정되었다. 이 광대역 델타시그마 분수분주형 주파수합성기는 $0.13{\mu}m$ CMOS공정으로 제작되었으며, 1.2 V 전원전압에서 15.8 mA의 전류를 소모한다.

A Highly Expandable Forwarded-Clock Receiver with Ultra-Slim Data Lane using Skew Calibration by Multi-Phase Edge Monitoring

  • Yoo, Byoung-Joo;Song, Ho-Young;Chi, Han-Kyu;Bae, Woo-Rham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권4호
    • /
    • pp.433-448
    • /
    • 2012
  • A source-synchronous receiver based on a delay-locked loop is presented. It employs a shared global calibration control between channels, yet achieves channel expandability for high aggregate I/O bandwidth. The global calibration control accomplishes skew calibration, equalizer adaptation, and phase lock of all the channels in a calibration period, resulting in the reduced hardware overhead and area of each data lane. In addition, the weight-adjusted dual-interpolating delay cell, which is used in the multiphase DLL, guarantees sufficient phase linearity without using dummy delay cells, while offering a high-frequency operation. The proposed receiver is designed in the 90-nm CMOS technology, and achieves error-free eye openings of more than 0.5 UI across 9-28 inch Nelco4000-6 microstrips at 4-7 Gb/s and more than 0.42 UI at data rates of up to 9 Gb/s. The data lane occupies only $0.152mm^2$ and consumes 69.8 mW, while the rest of the receiver occupies $0.297mm^2$ and consumes 56.0 mW at the 7- Gb/s data-rate and supply voltage of 1.35 V.

수동형 원격탐지 FTIR 분광계의 Radiometric Calibration (Radiometric Calibration of FTIR Spectrometer For Passive Remote Sensing Application)

  • 김대성;박도현;최승기;나성웅
    • 한국광학회지
    • /
    • 제17권5호
    • /
    • pp.391-395
    • /
    • 2006
  • 본 논문에서는 온도 제어가 가능한 blackbody를 이용하여 수동형 FTIR 분광계의 radiometric calibration을 수행하고 타당성을 살펴보았다. Radiometric calibration은 분광계로 입사되는 radiance의 온도 변화에 대한 광 검출기의 파장 별 응답특성과 기기 내부에서 발생되는 온도 및 반사율에 의해 발생되는 측정 오차를 보정하여 Planck radiance로 변환하는 기법이다. 시료에 대한 calibration 과정을 수행한 스펙트럼을 spectral library와 비교한 결과, 흡수 스펙트럼의 파장 별 선폭과 상대적인 intensity가 매우 유사하게 나타났으며 입사 광원의 온도차와 비례하여 spectral intensity가 일정하게 증가됨을 확인할 수 있었다.