• Title/Summary/Keyword: 2-Dimensional

Search Result 15,170, Processing Time 0.043 seconds

Wavelet Series Analysis of Axial Members with Stress Singularities (응력특이를 갖는 축방향 부재의 웨이블렛 급수해석)

  • Woo, Kwang-Sung;Jang, Young-Min;Lee, Dong-Woo;Lee, Sang-Yun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • The Fourier series uses a vibrating wave that possesses an amplitude that is like the one of the sine curve. Therefore, the functions used in the Fourier series do not change due to the value of the frequency and that set a limit to express irregular signals with rapid oscillations or with discontinuities in localized regions. However, the wavelet series analysis(WSA) method supplements these limits of the Fourier series by a linear combination of a suitable number of wavelets. By using the wavelet that is focused on time, it is able to give changes to the range in the cycle. Also, this enables to express a signal more efficiently that has singular configuration and that is flowing. The main objective of this study is to propose a scheme called wavelet series analysis for the application of wavelet theory to one-dimensional problems represented by the second-order elliptic equation and to evaluate theperformance of proposed scheme comparing with the finite element analysis. After a through evaluation of different types of wavelets, the HAT wavelet system is chosen as a wavelet function as well as a scaling function. It can be stated that the WSA method is as efficient as the FEA method in the case of axial bars with distributed loads, but the WSA method is more accurate than the FEA method at the singular points and its computation time is less.

The Change of Facial Contouring after Unilateral Injection of Botulinum Toxin in Unilateral Masseter Hypertrophy Patients (편측성 교근비대 환자에서 편측 보툴리눔 독소 주사 후 안모의 변화)

  • Cha, Yu-Rim;Kim, Young-Gun;Kim, Ji-Hyun;Shim, Young-Joo;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.247-251
    • /
    • 2011
  • Botulinum toxin type A (BoNT-A) is used for treating bilateral masseter hypertrophy since 1994. Recently there have been more clinical studies in this area, with some authors reporting that BoNT-A can reduce the size of the masseter muscle, as documented by photography, ultrasonography, computed tomography, and 3D(three dimensional) laser scan. However, earlier studies were only for bilateral masseter hypertrophy cases, not for unilateral masseter hypertrophy cases. The aim of this study was to use 3D laser scanning to evaluate changes in the external facial contour induced by unilateral BoNT-A injection. BoNT-A was injected into hypertrophic masseter muscle unilaterally in 10 patients with asymmetric masseter hypertrophy. The clinical effects of unilaterally injected BoNT-A were evaluated before the injection and 4, 8, and 12weeks after the injection using 3D laser scan. And the mean values of both sides (injection and non-injection sides) were compared with. At injection side, mean values of the volume and the bulkiest height at each time point diminished significantly between pre-injection and 4, 8, and 12weeks post-injection. At non-injection side, in contrast, mean values of the volume and the bulkiest height diminished also but less than that of injected side, and there was no statistical significance. In this limited study, we concluded that the unilaterally BoNT-A injection side showed greater mean values of the reduction of muscle volume than non-injection side at 4, 8, and 12 weeks after the injection.

Application of the Poisson Cluster Rainfall Generation Model to the Urban Flood Analysis (포아송 클러스터 강우 생성 모형을 이용한 도시 홍수 해석)

  • Park, Hyunjin;Yang, Jungsuk;Han, Jaemoon;Kim, Dongkyun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.729-741
    • /
    • 2015
  • This study examined the applicability of MBLRP (Modified Bartlett-Lewis Rectangular Pulse) rainfall generation model for an urban flood simulation which is a type of Poisson cluster rainfall generation model. This study constructed XP-SWMM model for Namgajwa area of Hongjecheon basin, which is a two-dimensional pipe network-surface flood simulation program and computed a flood discharge and a flooded area with input data of synthetic rainfall time series of 200 years that were generated by the MBLRP model. This study compared the data of flood with synthetic rainfall and flood with corresponding values which were based on design rainfall. The results showed that the flooded area computed with MBLRP model was somewhat smaller than the corresponding values on the basis of the design. A degree of underestimation was from 8% (5 year) to 34% (200 year) and the degree of underestimation increased as a return period increased. This study is meaningful in that it proposes methodology that enables quantifiability of uncertain variables which are related to a flooding through Monte Carlo analysis of urban flooding simulation and applicability and limitations thereof.

Development and Validation of A Decision Support System for the Real-time Monitoring and Management of Reservoir Turbidity Flows: A Case Study for Daecheong Dam (실시간 저수지 탁수 감시 및 관리를 위한 의사결정지원시스템 개발 및 검증: 대청댐 사례)

  • Chung, Se-Woong;Jung, Yong-Rak;Ko, Ick-Hwan;Kim, Nam-Il
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.3
    • /
    • pp.293-303
    • /
    • 2008
  • Reservoir turbidity flows degrade the efficiency and sustainability of water supply system in many countries located in monsoon climate region. A decision support system called RTMMS aimed to assist reservoir operations was developed for the real time monitoring, modeling, and management of turbidity flows induced by flood runoffs in Daecheong reservoir. RTMMS consists of a real time data acquisition module that collects and stores field monitoring data, a data assimilation module that assists pre-processing of model input data, a two dimensional numerical model for the simulation of reservoir hydrodynamics and turbidity, and a post-processor that aids the analysis of simulation results and alternative management scenarios. RTMMS was calibrated using field data obtained during the flood season of 2004, and applied to real-time simulations of flood events occurred on July of 2006 for assessing its predictive capability. The system showed fairly satisfactory performance in reproducing the density flow regimes and fate of turbidity plumes in the reservoir with efficient computation time that is a vital requirement for a real time application. The configurations of RTMMS suggested in this study can be adopted in many reservoirs that have similar turbidity issues for better management of water supply utilities and downstream aquatic ecosystem.

A Selection of Building Registration Method to Construct the Three Dimensional Information Cadastral Map (3차원정보지적도 모형 구축을 위한 건물등록 방법 선정)

  • Yang In Tae;Oh Yi Kyun;Yu Young Geol;Chun Gi Sun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Recently, in a field of cadastre, a computerization of cadastral map is in progress with great growth of GSIS field. Also, the needs fer the integration of land and building information are widely increasing for integral-management and its application of various land related information. Through a revision of cadastral laws to replace the existing 2D-Cadastre with the 3D-Cadastre, a legal basis to register the position of buildings and facilities is prepared in the governmental or civil fields. This paper presented 3D-Cadastre theory that has been studied on Europe and surveyed building position directly with Totalstation at cadastral control point after choosing pilot test area, Also, the most efficient surveying method of registering building in a cadastral map is presented with comparing and analyzing building position after surveying digital orthophoto and digital map. And it is constructed a 3D information cadastral map model that can make the integral management of land, building, connecting land recorders, building management ledgers, building titles, building pictures, and related attribute information.

Behaviors of Pile Croup Installed Near Inclined Ground (경사지반에 인접하여 설치된 무리말뚝의 거동연구)

  • Chae, Kwang-Seok;Ugai, Keizo;Yoon, Gil-Lim
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.53-64
    • /
    • 2003
  • Many transmission towers, high-rise buildings and bridges are constructed near steep slopes and are supported by large-diameter piles. These structures may be subjected to large lateral loads, such as violent winds and earthquakes. Widely used types of foundations for these structures are pier foundations, which have large-diameters with high stiffness. The behavior of a pier foundation subjected to lateral loads is similar to that of a short rigid pile because both elements seem to fail by rotation developing passive resistance on opposite faces above and below the rotation point, unlike the behavior of a long flexible pile. This paper describes the results of several numerical studies performed with a three-dimensional finite element method (FEM) of model tests of a laterally loaded short pile located near slopes, respectively. In this paper, the results of model tests of single piles and pile groups subjected to lateral loading, in homogeneous sand with 30$^{\circ}$ slopes and horizontal ground were analyzed by the 3-D FE analyses. The pile was assumed to be linearly elastic. The sand was assumed to have non-associative characteristics, following the MC-DP model. The failure criterion is governed by the Mohr-Coulomb equation and the plastic potential is given by the Drucker-Prager equation. The main purpose of this paper is the validation of the 3-D elasto-plastic FEM by comparisons with the experimental data.

Polydiacetylene-Based Chemo-/Biosensor of Label Free System with Various Sensing Tools (다양한 감지 방법을 갖고 있는 폴리디아세틸렌 기반 비표지 화학/바이오센서)

  • Park, Hyun-Kyu;Park, Hyun-Gyu;Chung, Bong-Hyun
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.409-413
    • /
    • 2007
  • Polydiacetylene(PDA)-based sensors possess a number of properties that can be successfully applied for label-free detection system. PDA is one of the most attractive color-generating materials, with growing applications as sensors. Here we introduce various PDA-based devices, used as biosensor, chemosensor, thermosensor, and optoelectronics sensor. In general, PDA liposomes and films are closely packed and properly designed for polymerization via 1,4-addition reaction to form an ene-yne alternating polymer chain. PDA-based two/three dimensional structures have been used for colorimetric or fluorescent devices, sensing biological as well as chemical components. This color-generating material also present a very high charge carrier mobility, allowing its application as field-effect transistor (FET). The immobilized PDA structures or films have distinct advantages for the detection of low concentration target molecules over the aqueous solution-based detection systems. In the present review, reported detection methods by using various PDA structures are summarized with updated references.

Usefulness of Computed Tomography Gastrography in the Surgical Management of a Gastric GIST (위에 발생한 위장관간질종양의 수술적 치료에서 Computed Tomogrophy Gastrography의 유용성)

  • Han, Dong-Seok;Lee, Hyuk-Joon;Lee, Min-Woo;Kim, Se-Hyung;Lee, Kuhn-Uk;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.6 no.4
    • /
    • pp.207-213
    • /
    • 2006
  • Purpose: This study was performed to evaluate the usefulness of computed tomography (CT) gastrography in the surgical management of a gastric gastrointestinal stromal tumor (GIST). Materials and Methods: We retrospectively analyzed the clinicopathologic data of 38 patients who had undergone CT gastrography from among patients who had gastric GISTS surgically resected at the Department of Surgery, Seoul National University Hospital, between January 2001 and February 2006. We compared CT gastrography data, including tumor size and location and distance from the gastroesophageal junction or pylorus with endoscopic, surgical and pathologic findings. Results: The longitudinal tumor locations on CT gastrography and endoscopy were identical to the surgical findings. For tumor sizes on CT gastrography of less than 5 cm, we performed 11 (42.3%) laparoscopic wedge resections from among 26 cases. In the 12 cases with tumor sizes of 5 cm or over, only 1 (8.3%) laparoscopic wedge resection was performed. When the tumor was located in the middle third of the stomach, a laparoscopic wedge resection was performed in 88.9% (8/9) of the cases, but when it was located in the upper or lower third, a laparoscopic wedge resection was performed in only 13.8% (4/29) of the cases. Conclusion: Three-dimensional information from CT gastrography allows the surgeon to perform preoperative planning, including accurate localization.

  • PDF

Wall Shear Stress Distribution in the Abdominal Aortic Bifurcation : Influence of wall Motion, Impedance Phase Angle, and non-Newtonian fluid (복부대동맥 분기관에서의 벽면전단응력 분포 벽면운동과 임피던스 페이즈 앵글과 비뉴턴유체의 영향)

  • Choi J.H.;Kim C.J.;Lee C.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.261-271
    • /
    • 2000
  • The present study investigated flow dynamics of a two-dimensional abdominal aortic bifurcation model under sinusoidal flow conditions considering wall motion. impedance phase angle(time delay between pressure and flow waveforms), and non-Newtonian fluid using computational fluid dynamics. The wall shear stress showed large variations in the bifurcated region and the wall motion reduced amplitude of wall shear stress significantly. As the impedance phase angle was changed to more negative values, the mean wall shear stress (time-averaged) decreased while the amplitude (oscillatory) of wall shear stress increased. At the curvature site on the outer wall where the mean wall shear stress approached zero. influence of the phase angle was relatively large. The mean wall shear stress decreased by $50\%$ in the $-90^{\circ}$ phase angle (flow wave advanced pressure wave by a quarter period) compared to the $0^{\circ}$ phase angle while the amplitude of wall shear stress increased by $15\%$. Therefore, hypertensive patients who tend to have large negative phase angles become more vulnerable to atherosclerosis according to the low and oscillatory shear stress theory because of the reduced mean and the increased oscillatory wall shear stresses. Non-Newtonian characteristics of fluid substantially increased the mean wall shear stress resulting in a less vulnerable state to atherosclerosis.

  • PDF

Finite Element Analysis for the Contact Stress of Ultra-high Molecular Weight Polyethylene in Total Knee Arthroplasty (전 슬관절 치환 성형술에 사용되는 초고분자량 폴리에틸렌 삽입물의 접촉응력에 관한 유한요소해석)

  • Jo, Cheol-Hyeong;Choe, Jae-Bong;Choe, Gwi-Won;Yun, Gang-Seop;Gang, Seung-Baek
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 1999
  • Because of bone resorption, wear of ultra-high molecular weight polyethylene(UHMWPE) in total knee arthroplasty has been recognized as a major factor in long-term failure of knee implant. The surface damage and the following harmful wear debris of UHMWPE is largely related to contact stress. Most of the previous studies focused on the contact condition only at the articulating surface of UHMWPE. Recently, contact stress at the metal-backing interface has been implicated as one of major factors in UHMWPE wear. Therefore, the purpose of the is study is to investigate the effect of the contact stress for different thickness, conformity friction coefficient, and flexion degree of the UHMWPE component in total knee system, considering the contact conditions at both interfaces. In this study, a two-dimensional non-linear plane strain finite element model was developed. The results showed that the maximum value of von-Mises stress occurred below the articulating surface and the contact stress was lower for the more conforming models. All-polyethylene component showed lower stress distribution than the metal-backed component. With increased friction coefficient on the tibiofemoral contact surface, the maximum shear stress increased about twofold.

  • PDF