• 제목/요약/키워드: 2 cavity process

검색결과 201건 처리시간 0.029초

PIM기술을 이용한 마이크로 부품 성형기술 (Manufacturing technology of micro parts by powder injection molding)

  • 이원식;고세현;장진만;김일호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.60-63
    • /
    • 2009
  • Manufacturing technologies of micro spur gear and micro mold by micro PIM were studied with stainless steel feedstock. For molding of gears, micro mold with gear cavity of 1.2 mm in diameter was produced by wire EDM. The proper injection pressure was selected to 70bar by observation and measuring of shapes and shrinkage of gears before/after sintering. For fabrication of micro mold, a tiny polymer gear was produced by injection into the mold. Then, 316L feedstock was again injected/compressed on the polymer gear and debinded together with polymer gear followed by sintering. As a result, another metal mold with gear cavity reduced to about 20% was fabricated and through repetition of this process chain, micro gear mold with cavity about below 800 um was finally obtained. In reduction of size by injection/compression molding, height of gear tooth was shrunk more and the effort for decrease of roughness of micro cavity were carried out ultrasonic polishing and as a result, the roughness in cavity decreased from 3-4 um to about 200 nm.

  • PDF

렌즈 사출성형 공정 상태 특징 추출 및 진단 알고리즘의 개발 (A Development of Feature Extraction and Condition Diagnosis Algorithm for Lens Injection Molding Process)

  • 백대성;남정수;이상원
    • 한국정밀공학회지
    • /
    • 제31권11호
    • /
    • pp.1031-1040
    • /
    • 2014
  • In this paper, a new condition diagnosis algorithm for the lens injection molding process using various features extracted from cavity pressure, nozzle pressure and screw position signals is developed with the aid of probability neural network (PNN) method. A new feature extraction method is developed for identifying five (5), seven (7) and two (2) critical features from cavity pressure, nozzle pressure and screw position signals, respectively. The node energies extracted from cavity and nozzle pressure signals are also considered based on wavelet packet decomposition (WPD). The PNN method is introduced to build the condition diagnosis model by considering the extracted features and node energies. A series of the lens injection molding experiments are conducted to validate the model, and it is demonstrated that the proposed condition diagnosis model is useful with high diagnosis accuracy.

전남지역 대학생의 구강건강행위에 대한 관련 요인 (Relation Factors of Oral Health Behavior of Junior College in Jeollanamdo)

  • 장윤정;정진아;전은숙
    • 한국치위생학회지
    • /
    • 제6권4호
    • /
    • pp.387-402
    • /
    • 2006
  • This research carried out a survey for 569 students in a junior college of jeollanamdo to provide a needful basic data in developing suitable health promotion program and creating a direction of the oral hygiene education process to intial adult population after holding the oral cavity health action and a affecting factors to it. A collected data obtained the following conclusion. According to school grade, a difference of action factor is Chi-square and Pearson's correlation coeficient in actionfactor and acknowledgement-perception factor and a step-by-step recurrence analysis processed a related factor of the oral health action. 1. A related action factor of the oral health appeared meaningful difference of the oral cavity medical examination, the oral cavity clean device use or not, dental surgery prevention cure or not among the third grade who had the most experience of the oral hygiene education within one year recently. 2. A significant of the oral cavity health acknowledged and perceived and a concern of the oral cavity health, acknowledged the oral cavity health state distribution are the highest in the third grade. 3. According to monthly income, a large income is higher than a small income about self-effects in a relation between the oral cavity health action and acknowledgement-perception factor. the average of a large income is 30.59(${\pm}5.79$). The obstacle of the oral cavity health action is 12.51(${\pm}3.19$). a large income is highest. according to school career, under middle school layer obtained the highest average 16.33(${\pm}3.53$). according to a school year, acknowledge-perception factor of the oral cavity health control of the third grade is the highest(38.81(${\pm}6.25$). 4. In mutual relation between acknowledge-perception factor and the oral cavity health action, a variable constants of meaningful mutual relation are the oral cavity health perception, self-effects, the oral cavity health action obstacle, the oral cavity health action benefit, the oral health action control, aggressive. and they are self-effects, the oral cavity health action in the oral cavity health perception. A significant of the oral cavity health and the oral cavity health action obstacle are the oral cavity health action benefit and the oral cavity health action control. 5. The affecting factors to the oral health action are self-effects, action factor, acknowledged the oral health control.

  • PDF

전산화단층영상에서 절치관 및 순측 치조골 폭경에 관한 연구 (The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images)

  • 노양균;장현선;김병옥;김진수
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.145-149
    • /
    • 2006
  • Purpose : To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Materials and Methods : Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal was selected and scanned with 600 DPI resolution. The width of the labial alveolar bone of the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1 The statistical analyses were carried out using SPSS 12.0.1. Results : When the maxillary central incisors remained, the mean labial alveolar bone width were $6.81{\pm}1.41mm,\;6.46{\pm}1.33mm$, and $7.91{\pm}1.33mm$. When the maxillary central incisors were missed the mean width were $5.42{\pm}2.20mm,\;6.23{\pm}2.29mm$, and $7.89{\pm}2.13mm$. Conclusions : The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to nasal cavity revealed statistically significant difference (P<0.05).

  • PDF

A novel approach for predicting lateral displacement caused by pile installation

  • Li, Chao;Zou, Jin-feng;Li, Lin
    • Geomechanics and Engineering
    • /
    • 제20권2호
    • /
    • pp.147-154
    • /
    • 2020
  • A novel approach for predicting lateral displacement caused by pile installation in anisotropic clay is presented, on the basis of the cylindrical and spherical cavities expansion theory. The K0-based modified Cam-clay (K0-MCC) model is adopted for the K0-consolidated clay and the process of pile installation is taken as the cavity expansion problem in undrained condition. The radial displacement of plastic region is obtained by combining the cavity wall boundary and the elastic-plastic (EP) boundary conditions. The predicted equations of lateral displacement during single pile and multi-pile installation are proposed, and the hydraulic fracture problem in the vicinity of the pile tip is investigated. The comparison between the lateral displacement obtained from the presented approach and the measured data from Chai et al. (2005) is carried out and shows a good agreement. It is suggested that the presented approach is a useful tool for the design of soft subsoil improvement resulting from the pile installation.

도로하부 공동 내의 지하수 주입 실험을 통한 공동 영역 변화 연구 (A Study on the Change of Cavity Area through Groundwater Injection Test under Pavement Cavity)

  • 김상목;최현;윤진성;박정준
    • 한국재난정보학회 논문집
    • /
    • 제16권2호
    • /
    • pp.267-275
    • /
    • 2020
  • 연구목적: 본 연구에서는 공동 영역의 변화를 규명하기 위해 GPR 탐사장비, 유량계, 천공기, 공내 촬영장비, 공동 형상화 장비 등을 사용하여 공동 체적에 비례한 일정량의 물을 주입하고, 주입한 물이 빠짐에 따라 확대되는 공동 영역 변화를 정량적으로 평가하였다. 연구방법: 지하수 주입에 의한 공동 체적변화를 살펴보기 위해 실험공 2개소에 대한 주입시간-주입유량-체적증가량을 측정하였다. 연구결과: 주입시간이 증가할수록 체적증가량은 감소하고 있으며 1시간 정도 주입하면 더 이상의 체적증가가 없음을 알 수 있었다. 결론: 주입실험을 통해 체적변화 양상을 분석하여 공동생성의 원인이 주변 지중 매설물에 대한 영향 유무를 판단할 수 있었다. 그리고 지하수 주입 시, 공동이 확장되는 과정에서 주변의 이완된 지반이 일부 붕괴되거나 세립토가 주변 지반의 간극을 채우기 때문이며, 지하수 주입 유량이 증가할수록 체적변화가 증가하는 것으로 미루어, 공동의 확장은 지하수 유동에 큰 영향이 있음을 알 수 있었다.

Effects of Process Variables on the Gas Penetrated Part in Gas-Assisted Injection Molding

  • Han, Seong-Ryeol;Park, Tae-Won;Jeong, Yeong-Deug
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.8-11
    • /
    • 2006
  • Gas-assisted injection molding (GAIM) process reduces the required injection pressure during mold filling stage as well as the shrinkage and warpage of the part and cycle time. Despite of these advantages, this process needs new parameters and makes the application more difficult because gas and melt interact during the injection molding process. Important GAIM factors involved in this process are gas penetration design, locations of gas injection points, shot size, delay time to inject gas as well as common injection molding parameters. In this study, the experiments are conducted to investigate effects of GAIM process variables on the gas penetration for PP (Polypropylene) and ABS (Acrylonitrile Butadiene Styrene) moldings by changing the gas injection point. Taguchi method is used for the design of the experiments. When the gas is injected at a cavity's center, the most effective factor is the shot size. When the gas is injected at a cavity's end, the most effective factor is the melt temperature. The injection speed is also an effective factor in GAIM process.

2차원 대칭 스트럿 주위의 초월 공동 유동 문제의 해석 (Super-Cavitating Flow Problems about Two-Dimensional Symmetric Strut)

  • 김영기;이창섭
    • 대한조선학회지
    • /
    • 제27권4호
    • /
    • pp.15-26
    • /
    • 1990
  • 본 연구는 표면 양력관 이론을 이용하여 초월 공동이 발생한 2차원 날개의 유동해석을 위한 제반 경계 조건을 검증하고 공동 뒷부분의 모형을 비교 검토한다. 해석해가 존재하는 2차원 대칭 스트럿 주위의 초월 공동 현상을 수치적으로 해석하여 그 결과를 해석해와 비교함으로써 표면 양력판 이론에 의한 프로펠러 공동 문제 해석의 가능성을 입증하였다. 특히, 공동 뒷부분의 비 선형 닫힘 모형, 타원형 닫힘 모형, 그리고 선형 닫힘 조건을 서로 비교 분석함으로써 공동 문제 해결에서 가장 중요한 공동 닫힘 조건의 영향을 보였다.

  • PDF

구강내 종양환자의 방사선 치료시의 Patient Care (The Patient Care During Before Radiotherapy in Oral Cavity Cancer)

  • 전병철;박재일
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.92-96
    • /
    • 1995
  • All patients who will Undergo irraidiation of the oral cavity cancer will need dental before and during Radiotherapy. The extent of the region and the presence of numerous critical normal tissues(mucosa, gingiva, teeth and the alveolar ridge, alveolar bony structure, etc) in the oral cavity area, injury to which could result in serious functional impairment. Therefore I evaluate the Usefulness of custom-made intraoral shielding device before and during Radiotherapy in oral cavity cancer. Materials and Methods(1) : Manufacture process of Custom-made intraoral shielding device Containing Cerroband. A. Acquisition of impression B. Matrix Constitution C. Separation by Separator D. Sprincle on method E. Trimming F. Spacing G. Fill with Cerroband Materials and Methods (2) A. Preannealing B. TLD Set up C. Annealing D. TLD Reading = Results = Therefore dosimetric characteristics in oral cavity by TLD Compared to isodose curve dose distribution Ipsilateral oral mucosa, Contralateral oral mucosa, alveolar ridge, tongue, dose was reduced by intraoral shielding device containning Cerroband technique Compard to isodose plan = Conclusions = The custom-made intra-oral shielding device containing Cerroband was useful in reducing the Contralateral oral mucosa dose and Volume irradiated.

  • PDF

사출금형의 냉각채널 성능 평가 (PERFORMANCE EVALUATION OF COOLING CHANNELS IN A PLASTIC INJECTION MOLD MODEL)

  • 김현수;한병윤;이일천;김영만;박형구
    • 한국전산유체공학회지
    • /
    • 제17권2호
    • /
    • pp.53-57
    • /
    • 2012
  • Design of the cooling channels of a plastic injection mold affects the quality and the productivity of the injection processes. In the injection process, the melted resin with high temperature enters the mold cavity, and just after the cavity is filled the heat should be dissipated through the cooling channels simultaneously. The purpose of this study is to analyse the heat transfer phenomenon and to estimate the temperature distribution in the mold to evaluate the cooling effect of the channels. The injection mold is assumed to have cooling channels of circular cross section and each channel has the same coolant flow rate. and The cavity has a rectangular shape. The results show that as the cooling channels get closer to the cavity surface, the cooling efficiency increases as might easily be guessed. However, due to the final hot resin flow from the gate an intensive cooling is required in that region.