• Title/Summary/Keyword: 2차 고조파

Search Result 208, Processing Time 0.028 seconds

Analysis of Harmonic Wave Generation in Nonlinear Oblique Crack Surface (비선형 경사 균열면에서의 고조파 발생 특성 해석)

  • Kim, Noh-Yu;Yang, Seung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.376-387
    • /
    • 2012
  • Based on the nonlinear spring model coupled with perturbation method, 2nd harmonic waves generated by oblique incident ultrasound on nonlinear crack interface were calculated and investigated. Reflected and transmitted waves from the interface were determined and analyzed at various angle of incidence for the cracks with different interfacial stiffness in order to estimate the 2nd harmonic generation of incident ultrasound. It was shown in computer simulation that the 2nd harmonic components changed much with the increase of incidence angle in both reflected and transmitted wave, but became very small when the incident angle approached toward 90 degree. It can be concluded that the 2nd harmonic component of reflected wave has a meaningful amplitude as much as the transmitted 2nd harmonic wave from partly closed crack.

Compensation of Harmonic Distortion in Grid-Connected Single-Phase Wind Power Generation Systems by Using a PR Controller (비례공진 제어기를 이용한 계통연계형 단상 풍력발전기의 고조파 왜곡보상)

  • Kim, Jong-Kyu;Lee, Jong-Hyun;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.67-68
    • /
    • 2012
  • 본 논문에서는 계통연계형 단상 풍력발전 시스템에 발생하는 2차 고조파를 보상하는 기법을 제안한다. 단상 소형풍력 발전 시스템은 직류단에 필연적으로 2차 고조파 성분을 갖게 되며, 이는 출력전류의 왜곡을 야기한다. 제안하는 방법은 직류단 전압의 2차 고조파를 제거하는 기존의 기법과는 달리, 비례공진 제어기로 출력전류 지령의 2차 고조파를 제거하여 출력전류의 왜곡을 보상한다. 제안하는 기법은 복잡한 연산 없이 고조파를 보상할 수 있다. 시뮬레이션을 통해 제안된 알고리즘의 우수한 제어특성을 확인한다.

  • PDF

A Study on the Harmonic Evaluation Algorithm for Dispersed Sources in Distribution Systems (배전계통에 있어서 분산전원의 고조파 평가 알고리즘에 관한 연구)

  • Kang, Min-Kwan;Park, Jae-Ho;Rho, Dae-Seok;Oh, Yong-Taek;Hong, Sang-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.543-544
    • /
    • 2006
  • 본 논문에서는 고조파 환경 목표레벨을 유지시키기 위하여, 고조파의 발생원인 수용가가 고조파 유출에 대한 평가 알고리즘을 제시한 것이다. 이 평가 알고리즘은 단계 별로 이루어지는데, 수용가(특수/보통)의 종류판정과 고조파 유출전류 계산 및 억제대책의 여부판정 그리고 마지막으로 고조파 대책 검토 최종 단계에 의해 역율 개선과 고조파의 발생량을 저감하기 위하여 동력변압기의 2차 측에 직렬리액터가 있는 콘덴서를 설치하고, 리액턴스를 고려 해 계산하여 유출량계산 및 상한치와 비교 후, 고조파 대책을 실시한다. 각 차 고조파에 대하여 상한치 이내로 고조파가 저감되어 기준치를 만족하면 다른 조파도 동일한 방법으로 검토한다.

  • PDF

Islanding Detection Method by Injecting Second Order Harmonic Current for Inverter-Based Distributed Generators (2고조파 전류 주입을 적용한 분산전원 인버터 기반의 단독운전 검출 방법)

  • Kim, Hyun-Jun;Yang, Won-Mo;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.232-233
    • /
    • 2016
  • 본 논문은 계통과 연계된 3상 전압원 인버터를 기반으로 한 BESS의 능동 단독 운전 검출 방법을 제안한다. 제안하는 기법은 PR제어기와 필터를 가지고 기본파 전류와 2차 고조파 전류를 이용해 수행하였다. 단독운전은 BESS로부터 정격전류의 1% 2차 고조파를 주입하기 때문에 PCC점에서의 2차 고조파 전압 변화량을 검출 할 수 있다. 제안하는 기법은 모든 조건하에 정확하고 빠르게 검출 할 수 있다. IEEE와 UL1741에서 제시하는 단독 운전 기준 시험 회로를 구성하여 PSCAD/EMTDC 소프트웨어를 통한 시뮬레이션과 5kW 하드웨어 장치를 통해 제안된 단독 운전 검출 방법을 검증하였다.

  • PDF

Measurement of Saturation Magnetostriction by the Second-order Higher Harmonics of ac Perturbing Magnetic Field (교류 섭동 자기장의 제 2차 고조파를 이용한 포화자기변헝 측정)

  • Cha, S.Y.;Kim, J.K.;Ryu, K.S.;Cho, Y.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.72-75
    • /
    • 2005
  • The profiles of the second-order higher harmonics during B-H hysteresis loop have been measured as functions of the tensile stress in grain-oriented $3.2{\%}$ Si steels. The observed harmonics profiles have been analyzed in terms of the nonlinear, asymmetric magnetization which reflects the domain reorientation under the field. The field interval of the second-order higher harmonics is related to the nucleation and annihilation fields and a measurement method for the magnetostriction is proposed using the harmonics profiles under tensile stress.

Very High Linearity of High Power Amplifier by Reduction of $2^{nd}$, $3^{rd}$ Harmonics and Predistortion of $3^{rd}$ IMD (3차 혼변조 신호의 전치왜곡과 2, 3차 고조파 억제를 통한 고선형성 고출력 전력 증폭기에 관한 연구)

  • Lee, Chong-Min;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.50-54
    • /
    • 2011
  • In this article, the linearity of single power amplifier is improved by suppress $2^{nd}$ and $3^{rd}$ harmonics at output port of high power amplifier and by cancelling of $3^{rd}$ IMD. The matching network in order to suppress harmonics consists of metamaterial like the CRLH. The $2^{nd}$ and $3^{rd}$ harmonics are suppressed over 27 dBc, respectively. A phase of generated $3^{rd}$ IMD at output of DPA (drive power amplifier) has changed in order to offset the $3^{rd}$ IMD of HPA (high power amplifier). The harmonics of the proposed PAM suppress over 6 dB than single HPA. The PAM has a 36.98 dBm of the output power, 21.6 dB of the power gain and 29.4 % of the PAE. The harmonics is a -53 dBc about PAM. This result indicate that a harmonic level is lower 20 dB than reference power amplifier.

A Design of Analog Predistortion Linearizer Using Even Harmonic Signals (짝수 고조파 성분을 이용한 아날로그 전치 왜곡 선형화기 설계)

  • Hwang Moon-Soo;Jeon Ki-Kyung;Kim Ell-Kou;Cho Suk-Hui;Kim Young;Kim Byung-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.67-73
    • /
    • 2006
  • This paper proposes a new predistortion linearizer with controlling intermodulation distortion(IMD) signals. This linearizer achieves independent control of third- and fifth-order intermodulation distortion products using amplitude modulation with even harmonic signals. A vector modulator that modulate fundamental signal with both second- and fourth-order harmonic components generated by harmonic generator circuits, generates the inverse characteristics third-and fifth-order intermodulation signals of power amplifier and controls amplitude and phase of them with each other modulation factors. As a results, this linearizer is suppressed IMD signals of power amplifier effectively. The test results show that the third IMD is cancelled more than 25 dB and the fifth order IMD is cancelled about 18 dB for CW two-tone signals. Also, it's improved the adjacent channel power ratio(ACPR) more than 7 dB for IS-95 CDMA signals.

New Control Scheme for 3 Phase PWM AC/DC Converter without Phase Angle Detection under Unbalanced Input Voltage Conditions (불평형 입력 전압 하에서 위상 검출이 없는 3상 PWM AC/DC 컨버터의 새로운 제어 기법)

  • 박규서;안성찬;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.254-260
    • /
    • 2000
  • 일반적으로 3상 PWM AC/DC 컨버터는 정상상태에서의 효과적인 오차제거 및 빠른 과도응답 특성을 얻기 위해 동기좌표계상으로 모델링하여 제어한다. 그러나 이와 같은 제어기는 입력전압이 평형일 경우를 전제조건으로 하므로, 입력전압이 불평형일 경우 입력전류와 직류링크 전압에 2차 고조파 성분이 나타나게 된다. 본 논문에서는 불평형 입력전압 하에서 컨버터 시스템의 입력전류와 직류링크 전압에 발생하는 2차 고조파 성분을 최소화하기 위한 새로운 제어기법을 제안하였다. 입력측 역기전력 성분으로 간주할 수 있는 동기좌표계상의 전압을 입력전압의 상태에 따라 변동하였으며, 전류지령치를 무효전력과 2차 고조파 유효전력을 선택적으로 제거하도록 선정하였다. 입력전압의 분석은 동기좌표계상에서 수행되어지며, 각 상의 위상과 진폭의 검출이 불필요하다. 제안한 제어기법은 매우 간단하며 불평형 입력전압 상태에서 입출력 시스템의 고조파 왜란을 효과적으로 제어할 수 있다.

  • PDF

Design and Fabrication of the Frequency Tripper for Medium Power (중전력 주파수 3체배기 설계 및 제작)

  • Roh, Hee-Jung;Lee, Byung-Sun
    • 전자공학회논문지 IE
    • /
    • v.47 no.3
    • /
    • pp.47-52
    • /
    • 2010
  • In this paper, a frequency tripler has been designed with 100mW medium-power using P-HEMT. It is designed to obtain 7.2GHz frequency at the output that is an integer multiple of 2.4GHz input frequency by using nonlinear device that produces 3rd harmonic. The frequency tripler is designed by using load-pull simulation. To suppress the 2nd and fundamental, notch filter is used for the frequency tripler. The tripler is designed to obtain about 21dBm output power with 15dBm input, i.e., 6dB conversion gain and the suppression of 20dBc at fundamental, and 30dBc at the second harmonics.

A Design of Predistortion Linearizer Using Second Harmonic Signals (2차 고조파 신호를 이용한 전치 왜곡 선형화기 설계)

  • Kim Sung-Yong;Kim Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.12 s.103
    • /
    • pp.1239-1245
    • /
    • 2005
  • In this paper, a new predistortion linearizer using second harmonic components feedforwarding is proposed. The harmonic generator of the proposed predistorter that consists of a small signal amplifier extracts second harmonic signals. A vector modulator that modulate fundamental signal with second harmonic signals, generates the inverse third order intermodulation distortion signals and controls amplitude/phase of them with modulation factors. As a result, this linearizer is suppressed IMD3 signals of power amplifier effectively. The test results show that the third order IMD of power amplifier is suppressed more than 20 dB for CW two-tone signals. Also, it's improved the adjacent channel power ratio(ACPR) more than 5 dB for CDMA(IS-95) 4FA signals.