Earthquake Simulation Tests of a 1 :5 Scale 3-Story Masonry-Infilled Reinforced Concrete Frame

  • Lee, Han-Seon;Woo, Sung-Woo;Heo, Yun-Sup
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.153-164
    • /
    • 1999
  • The objective of this research is to observe the actual response of a low-rise nonseismic moment-resisting masonry-infilled reinforced concrete frame subjected to varied levels of earthquake ground motions. The reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N2IE component earthquake ground motion, whose peak ground acceleration(PGA) was modified to 0.12g, 0.2g, 0.3g, and 0.4g. The g1oba1 behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of the structure were measured. Before and after each earthquake simulation test, free vibration tests and white noise tests were performed to find the changes in the natural period of the model. When the results of the masonry-infilled frame are compared with those of the bare frame, it can be recognized that masonry infills contribute to the large increase in the stiffness and strength of the g1oba1 structure whereas it also accompanies the increase of earthquake inertia forces. However, it is judged that masonry infills may be beneficial to the performance of the structure since the rate of increase in strength appears to be greater than that of the induced earthquake inertia forces.

  • PDF

말뚝 기초 고유진동수의 가속도 크기 의존성을 고려한 상사법칙 개발 (Development of the similitude law considering the intensity-dependent variation of natural frequency of pile foundation system)

  • 최정인;유민택;김성렬;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.905-912
    • /
    • 2009
  • 1-g shaking table test is conducted to evaluate the dynamic behavior of a soil-structure system under seismic loading condition. A consistent similitude law between the model and prototype is needed to predict the behavior of the prototype structure, quantitatively. The natural frequency of geomaterial decreases with the increase of shaking intensity because of the non-linear property of the geomaterial. This phenomenon affects the applicability of similitude laws in 1-g shaking table tests. In this study, a simple method is suggested to determine the frequency of the input motions in 1-g tests in order to enhance the applicability of similitude laws. Modified input frequency is calculated using the frequency ratio with consideration of the variation of the natural frequency according to the intensity of input ground acceleration. To verify the applicability of the suggested method, a series of 1-g shaking table tests were performed for three different sizes of model piles having an overburden mass on their heads by varying the acceleration and the frequency of input motion. The acceleration amplification ratio on the overburden mass, the lateral displacement at the pile head and the maximum bending moment along the pile depth were measured. The projected behaviors of the virtual prototype based on the measured values of the model tests, where the input frequencies were calculated by the new method, showed good consistency, verifying the applicability of the suggested method.

  • PDF

내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가 (Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment)

  • 정란;이정우;박태원
    • 콘크리트학회논문집
    • /
    • 제18권6호
    • /
    • pp.721-728
    • /
    • 2006
  • 지진은 구조물에 막대한 피해를 발생시키는 것으로 보고되고 있으나, 우리나라에 내진설계규정이 도입되기 전인 1988년 이전에 설계된 건물은 이에 대한 대책이 없다. 특히 공동주택의 경우 지진저항요소가 없는 구조물이 다수 있는 것으로 조사되었다. 이러한 구조물에 대하여 내진성능의 정도를 파악하고, 성능지수가 부족한 구조물에 대해서는 적절한 보강이 이루어져야 할 것이다. 본 연구에서는 이전의 연구에서 범용 구조해석 프로그램인 MIDAS를 이용하여 모델 구조물의 내진성능을 평가하여 얻어진 내진성능의 부족함을 기초로 5층 규모의 철근콘크리트 벽식 구조물에 상사법칙을 적용하고, 진동대 실험을 수행하여 국내외 규준에 의한 모델 구조물의 내진성능을 평가하였다. 진동대 실험의 경우 실험의 공간적 제약으로 인하여 원형 구조물에 대한 실험을 할 수 없어, 구조물의 원형크기를 상사법칙에 의하여 필요한 규모로 축소하여 제작하였다. 성능수준을 평가해 본 결과 내진설계가 수행되지 않은 구조물은 PGA 등급 0.2g의 지진에 대하여 사용한계수준의 내진성능을 나타내었으며 허용층간변위를 평가해 본 결과 0.2g의 지진등급까지만 허용한계수준의 층간변위를 나타내어 내진성능에 대한 보강이 필요할 것으로 판단되었다.

해저터널 내진성능 향상을 위한 Flexible segment 효용성 연구 (Study on flexible segment efficiency for seismic performance improvement of subsea tunnel)

  • 장동인;김종일;곽창원;박인준
    • 한국터널지하공간학회 논문집
    • /
    • 제19권3호
    • /
    • pp.503-515
    • /
    • 2017
  • 최근 대형화되고 있는 지하구조물은 평상시는 물론 지진시에도 안정성을 확보하여야 한다. 특히 지하구조물 중에서도 해저터널은 지진시 안정성 유지가 매우 중요하다고 할 수 있다. 본 논문의 목표는 해저터널의 지진시 안정성 유지에 획기적인 시설물 중의 하나인 Flexible segment에 대해서 진동대 시험을 이용한 효용성 검증이다. 검증된 결과를 토대로 3차원 동해석을 통해 Flexible segment의 최적위치를 제안하는 것이 또 다른 하나의 논문 목표이다. 본 연구 수행을 위해 선정한 가상해저터널 단면에 상사율(1:100)을 고려한 1g 진동대 시험(1g Shaking Table Test)을 경주지진파, 인공지진파, 종방향, 횡방향, Flexible segment유무 등을 고려해서 모두 8회 이상 수행하였다. 진동대 시험 수행결과 전 시험 모두에서 Flexible Segment가 해저터널 내진성능향상에 효과가 있음을 확인하였다. 또한 시험적으로 내진성능 향상에 효과가 검증된 Flexible segment의 최적 위치를 선정하기 위하여, 3차원 동적 수치해석을 수행하였다. 그 결과 분기구간에서 Flexible segment를 인접해 설치할 경우 지진가속도가 감쇠하는 것을 확인할 수 있었다.

1/12 축소 철근콘크리트 주상복합구조물의 진동대실험 (Shaking Table Tests of A 1/12-Scale Reinforced Concrete Upper-Wall Lower-Frame Structure)

  • 이한선;김상연;고동우;권기혁;김병현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.139-144
    • /
    • 2001
  • The objective of this study is to investigate the behavior of 1/12 scale upper-wall lower-frame reinforced concrete structure subjected to earthquake excitations. For this purpose, Taft N21E earthquake accelerogram was simulated by using 4m$\times$4m shaking table. When the input acceleration is compared to that of output, it was found that simulation of shaking table is satisfactory. From the test results with peak ground acceleration(PGA) 0.22g, which corresponds to 0.11g in prototype by the similitude law, it can be observed that the model responded in elastic behavior and that large interstory drift occurred at the lower part of the structure.

  • PDF

진동대 시험을 이용한 콘크리트 댐의 동적거동 특성 연구 (A Study on the Dynamic Behavior of Concrete Dam by Shaking Table Tests)

  • 황성춘
    • 한국소음진동공학회논문집
    • /
    • 제15권7호
    • /
    • pp.806-812
    • /
    • 2005
  • This paper adresses the shaking table tests with 1/100 scaled model followed similitude law for OOdam main designing section to understand nonlinear behavior characteristics of concrete dam body by ground motion. As earthquake wave, Hachinohe and El Centre waves were used and acceleration and displacements are measured to analyze behaviors of dam body. For maximum ground acceleration range $(0.3\~0.9 g)$, the results showed linear behavior regardless of maximum 9round acceleration and secured safety of structure. To analyze the behavior of dam after tension cracking, 3 cm-notch was placed at the critical section of over-flowing section. As results of applying Hachinohe wave(0.8 g), Even though tension cracks were formed at over-flowing section by Hachinohe wave(0.8 g), it showed that the dam is stable for supporting upper stream Part of water tank of dam.

1g 진동대 실험 및 등가정적해석을 이용한 억지말뚝의 사면안정 내진보강 효과 연구 (A Study on Seismic Retrofit Design of the Stabilized Piles by 1g Shaking Table Tests and Pseudo-static Analysis)

  • 한진태;조종석;유민택;이승현
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.93-101
    • /
    • 2011
  • 국토의 70% 이상이 산지인 국내 지형 조건에서 도로, 철도 등 크고 작은 건설 공사에서는 필연적으로 사면이 형성된다. 그러나, 최근 국내외적으로 빈번히 발생하는 지진에 대한 사면안정 보강공법에 대한 연구는 전무한 실정이다. 이에 본 연구에서는 1 g 진동대 실험 및 등가정적해석을 이용하여 사면의 내진 보강공법으로써 억지말뚝의 적용성을 평가하고, 억지말뚝이 적용된 사면 및 억지말뚝의 지진시 거동을 분석하였다. 1 g 진동대 실험 결과로부터, 억지말뚝 보강 사면의 지진시 사면파괴 억지효과를 검증하였으며, 등가정적해석을 통해 억지 말뚝을 사면 하부 또는 상부보다 사면 파괴면의 중앙부에 말뚝을 설치했을 때 사면파괴 억지효과가 가장 큼을 알 수 있었다. 또한, 말뚝이 사면 중앙부에 설치되었을 경우, 말뚝의 중심 간격에 따른 안전율 변화를 등가정적해석으로부터 분석하였다.

Centrifuge shaking table tests on a friction pendulum bearing isolated structure with a pile foundation in soft soil

  • Shu-Sheng, Qu;Yu, Chen;Yang, Lv
    • Earthquakes and Structures
    • /
    • 제23권6호
    • /
    • pp.517-526
    • /
    • 2022
  • Previous studies have shown that pile-soil interactions have significant influences on the isolation efficiency of an isolated structure. However, most of the existing tests were carried out using a 1-g shaking table, which cannot reproduce the soil stresses resulting in distortion of the simulated pile-soil interactions. In this study, a centrifuge shaking table modelling of the seismic responses of a friction pendulum bearing isolated structure with a pile foundation under earthquakes were conducted. The pile foundation structure was designed and constructed with a scale factor of 1:100. Two layers of the foundation soil, i.e., the bottom layer was made of plaster and the upper layer was normal soil, were carefully prepared to meet the similitude requirement. Seismic responses, including strains, displacement, acceleration, and soil pressure were collected. The settlement of the soil, sliding of the isolator, dynamic amplification factor and bending moment of the piles were analysed to reveal the influence of the soil structure interaction on the seismic performance of the structure. It is found that the soil rotates significantly under earthquake motions and the peak rotation is about 0.021 degree under 24.0 g motions. The isolator cannot return to the initial position after the tests because of the unrecoverable deformation of the soil and the friction between the curved surface of the slider and the concave plate.

1-g 진동대 모형시험을 위한 상사법칙의 적용성 평가 (Applicability of Similitude Laws for 1-g Shaking Table Tests)

  • 황재익;김성렬;김명모
    • 한국지반공학회논문집
    • /
    • 제20권3호
    • /
    • pp.141-150
    • /
    • 2004
  • 1995년 고베지진에 의해 피해를 입었던 중력식 안벽구조물과 잔교식 안벽구조물의 동적 거동을 재현하고, 분석하기 위하여 소규모 1-g 진동대 모형시험을 수행하였다. 1989년 Iai가 제안한 상사법칙을 이용하여 진동대 모형시험 결과를 원형크기의 것으로 환산하여 현장계측 결과와 비교하였다. 그 결과, 중력식 안벽구조물의 변위는 현장계측 결과의 약 1/3 정도 발생하였고, 벽체의 변형 형상은 원형과 유사하였다. 잔교식 안벽구조물의 변위는 현장계측 결과의 약 2/3 가 발생하였고, 말뚝에 발생하는 최대모멘트의 위치와 원형말뚝의 파괴위치는 잘 일치하였다.

진동대 실험을 이용한 암반비탈면의 가속도 특성 (Acceleration Behavior of Rock Slope by Shaking Table Test)

  • 강종철;윤원섭;박연준
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.841-848
    • /
    • 2021
  • This study investigated the acceleration characteristics of rock slopes when earthquakes, which have not been studied much in Korea, occur. The rock slope was modeled with a similar raw of 1/20 in consideration of the height(10m), roughness, strength, and the joint dips(20°). After the completion of the model, a shaking table tests was conducted according to the magnitude of the acceleration and the type of seismic wave. The maximum acceleration was greater in the short-period seismic wave than in the long-period seismic wave, and the maximum acceleration was larger in the small acceleration. The rock slope was close to a rigid block and a structure more vulnerable to the long period wave than to the short period wave. In the event of an earthquake smaller than the domestic earthquake-resistant maximum design acceleration(0.154g), safety management of the rock slope was required.