Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment  

Chung, Lan (Dept. of Architectural Engineering, Dankook University)
Lee, Joung-Woo (Dept. of Architectural Engineering, Dankook University)
Park, Tae-Won (Dept. of Architectural Engineering, Dankook University)
Publication Information
Journal of the Korea Concrete Institute / v.18, no.6, 2006 , pp. 721-728 More about this Journal
Abstract
Earthquakes are reported thai building structures have been colossal damaged, but before 1988 designed structures which were not applicate seismic design code have no seismic performance. Especially, for the apartment structures were indicated that it have no resist wall element of earthquake before 1988 designed structures. We have to evaluate for seismic performance this structures, therefore it will be retrofitted for seismic index sufficient structures. We performed seismic performance evaluation for model structures by MIDAS which is general structure analysis software. In this study, it was performed shaking table test to evaluate model structure which is reinforcement concrete and 5 floors for seismic performance index. We made specimens by similar's law and tested shaking table test. In the shaking table test it is not performed prototype model test because of space and equipment condition. So we had made scale-down model for 1/5 by similar's law. That's why it needs for the evaluation of performance. However, it is not possible to do an experiment of prototype owing to the shortage of space and the limit of an experimental instrument in the shaking table test. Then, modeling and reducing the part of prototype do the experiment. In this experiment a shaking table test is done and seismic performance of model structures is evaluated by using similitude laws for scale down specimen. As a result it is proved that non-seismic design structures need to retrofit since seismic performance shows life safe grade in 0.12g of an earthquake.
Keywords
seismic design; shaking table test; similitude laws; seismic performance; wall-type apartment;
Citations & Related Records
연도 인용수 순위
  • Reference
1 건설교통부 정기주택 통계자료, www.moct.go.kr
2 정 란, 우운택, 박태원, 나승욱, '전단변식 구조시스템의 내진성능평가 지표 산정', 한국지진공학회 추계학술표대회 논문집, 경희대학교, 수원, 6권 1호, pp.223-230
3 박태원, 벽식구조 공동주택의 내진성능 보강효과, 단국대학교 박사학위 논문, 2005, 8pp
4 Applied Technology Council, Seismic Evaluation and retrofit of Concrete Buildings, ATC-40 Redwood, C.A., 1996
5 Gulkan P. and Aozen M, 'Response and Energy Dissipation of Reinforced Concrete Frames Subjected to Strong Base Motion', Structural Research Series, No.3, Civil Engineering Studies, University of Illinois, Urbana, 1971, pp.336-342
6 박현수, 정란, 민정규, '상사법칙을 이용한 R/C부재의 모델링 기법', 대한건축학회 논문집 Vol.8, No.1 pp.191-199
7 International Conference of Building Officials, Uniform Building Code, UBC-97, SEAOC, California, 1997, Chapter 19
8 건설교통부, 건축구조설계기준, KBC-2005, pp.III-15