• 제목/요약/키워드: 154

검색결과 7,010건 처리시간 0.037초

154kV 변전소에서 피뢰장치의 뇌서지특성 해석 (A Study on the Analysis of the Lightning Surge Characteristics of Arresters in a 154kV Substation)

  • 윤창섭;조한구;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.433-439
    • /
    • 2006
  • This paper describes the characteristic evaluation of 154kV lightning arrester developed by domestic technology. To prove the protective ability of lightning arrester developed, various overvoltages were analyzed for A and B arrester were being used now at 154kV air and gas insulation substation, and for arrester developed. The results obtained by the various simulations show that the developed arrester has the effective protective ability and reducing ability of the overvoltage as A and B arrester, nevertheless there are somewhat differences among three kinds of arresters. Accordingly, it is evaluated that the arrester developed by domestic technology secured reliability can be installed actually at 154kV substation. In this paper, EMTP/ATP was used for simulation.

154kV급 전력-광복합케이블의 개발 (Development of the 154kV optical fiber incorporated power cable)

  • 류재규;유성종;전승익;조진철;최봉남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1639-1641
    • /
    • 1997
  • In this study, We developed the 154kV optical fiber incorporated power cable which is combined optical fibers with conventional 154kV power cable. Also, we developed optical unit that optical fiber is inserted in stainless tube. The optical unit was tested, and we got good results enough to safe optical fibers. Also we put the optical fiber incorporated power cable to the test of electrical characteristics and optical characteristics, we knew that the electrical characteristics were the same characteristics as conventional 154kV power cable and the transmission loss change was almost zero. The method of optical unit connection was examined.

  • PDF

154kV STATCOM(정지형 무효전력 보상장치) 국산화 최초설치 및 현장시험 (The Installation and Site Test of 154kV STATCOM)

  • 방선웅;민병욱;신명식;유현호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.170-171
    • /
    • 2011
  • 현재 제주지역 전력계통은 원형 모양의 다중계통으로 구성되어 있어 송전선로 고장 발생시 단일계통으로 운전됨에 따라 말단 측에 전압문제가 발생할 우려가 있을 뿐만 아니라, 대규모 풍력발전단지 조성 및 #2 HVDC 제주연계로 제주지역내 무효전력 수급 불균형 상황이 발생할 것으로 예상된다. 이에 따라 제주지역 전력계통 전압안정도 개선을 위하여 순동 무효전력 보상장치를 154kV 한라, 신제주변전소에 설치하기로 계획하였으며 154kV급 STATCOM(정지형 무효전력 보상장치)으로 결정되었다. 이번에 제주에 적용된 STATCOM은 미금변전소에 설치된 345kV급 STATCOM에 이어 국내기술로 개발된 설비로 154kV급으로는 처음 국내에 설치되었다. 제주지역 특성을 반영하여 변압기, 인버터 등 STATCOM 구성 주요기기에 대한 정격을 결정, 기술규격을 확정한 후 구매를 추진하였고 2011년 1월부터 설치를 착수하여 2011년 5월말 시운전 목표로 추진하고 있다. 본 논문에서는 국내에 최초로 적용되는 154kV급 STATCOM의 현장설치 주요과정에 대한 소개와 현장시험 주요항목 및 유의사항에 대해 기술하고 있다.

  • PDF

154kV 콤팩트 변전소 표준모델 개발 및 실증 (Development and Construction of 154kV Compact Substation Standard Model)

  • 민병욱;신명식;김태용;황윤곤;김영달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.436-437
    • /
    • 2011
  • Before 1970s, 154kV substations in Korea were built in outdoor steel structure types only. In early 1970s, Germany developed GIS and the first indoor GIS type substation was built in Korea in 1980. In 1998, 154kV indoor type substations were standardized into regular type and urban type which applied steel frames to structures. In 2002, this was re-standardized into five different types in detail. In 2009, 154kV compact substation design was developed and standardized and saved about 20% of the construction cost with new technology and methods. Compact substations were classified into three types ; urban type, multi-function type, and regular type. The first urban type compact substation, Jang-ki substation, was built in Kimpo in June, 2010. This paper would present the standard model of 154kV compact substation and the way of improving facilities for the first compact substation.

  • PDF

154kV, 1GVA 초전도케이블 설계 (Design of 154kV, 1GVA HTS Cable)

  • 조전욱;심기덕;김석호;이수길;장현만;최창열;이근태;양병모;김성래
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.192-192
    • /
    • 2010
  • DAPAS (Development of Advanced Power system by Applied Superconductivity technologies) program that the, superconductivity national program has been started one of the 21C frontier programs from 2001 in Korea. The 3rd phase of DAPAS program was started at April 2007, and the ultimate goal of HTS cable project is to develop 154kV, 1GVA class HTS cable. The structure of 154kV, 1GVA HTS cable is single core with cold dielectric insulation. The cable core consists of the former, conduction layer, electrical insulation layer, shielding layer. The cable cryostat consists of two corrugated seamless aluminum tubes as its high sealing reliability, the tubes separated through a spacer arrangement. Outdoor termination was developed by LS cable and cryogenic system by CVE for 154kV, 1GVA class HTS cable. The 154kV, 1GVA HTS cable will be installed and be tested in KEPCO Gochang Testing Center from June 2010.

  • PDF

Intracellular CD154 Expression Reflects Antigen-specific $CD8^+\;T$ Cells but Shows Less Sensitivity than Intracellular Cytokine and MHC Tetramer Staining

  • Han, Young-Woo;Aleyas, Abi G.;George, Junu A.;Yoon, Hyun-A;Lee, John-Hwa;Kim, Byung-Sam;Eo, Seong-Kug
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권12호
    • /
    • pp.1955-1964
    • /
    • 2007
  • A recent report showed that analysis of CD154 expression in the presence of the secretion inhibitor Brefeldin A (Bref A) could be used to assess the entire repertoire of antigen-specific $CD4^+\;T$ helper cells. However, the capacity of intracellular CD154 expression to identify antigen-specific $CD8^+\;T$ cells has yet to be investigated. In this study, we compared the ability of intracellular CD154 expression to assess antigen-specific $CD8^+\;T$ cells with that of accepted standard assays, namely intracellular cytokine IFN-${\gamma}$ staining (ICS) and MHC class I tetramer staining. The detection of intracellular CD154 molecules in the presence of Bref A reflected the kinetic trend of antigen-specific $CD8^+\;T$ cell number, but unfortunately showed less sensitivity than ICS and tetramer staining. However, ICS levels peaked and saturated 8 h after antigenic stimulation in the presence of Bref A and then declined, whereas intracellular CD154 expression peaked by 8 h and maintained the saturated level up to 24 h post-stimulation. Moreover, intracellular CD154 expression in antigen-specific $CD8^+\;T$ cells developed in the absence of $CD4^+\;T$ cells changed little, whereas the number of IFN-${\gamma}$-producing $CD8^+\;T$ cells decreased abruptly. These results suggest that intracellular CD154 could aid the assessment of antigen-specific $CD8^+\;T$ cells, but does not have as much ability to identify heterogeneous $CD4^+\;T$ helper cells. Therefore, the combined analytical techniques of ICS and tetramer staining together with intracellular CD154 assays may be able to provide useful information on the accurate phenotype and functionality of antigen-specific $CD8^+\;T$ cells.

진동시험에 의한 154kV 변압기 부싱의 동특성 분석 및 내진성능 평가 (Modal Identification and Seismic Performance Evaluation of 154kV Transformer Porcelain Bushing by Vibration Test)

  • 조양희;조성국
    • 한국지진공학회논문집
    • /
    • 제10권5호
    • /
    • pp.107-115
    • /
    • 2006
  • 지진과 같은 재난이 발생하였을 때에도 전력설비는 그 본래의 기능을 상실하지 않고 구조적인 안정성을 유지해야 하는 핵심 산업시설물이다. 이 연구는 가장 대표적인 전력설비인 154kV 변압기에 부착된 애자형 부싱의 진동특성과 내진성능을 분석하였다. 연구의 목적에 따라 국내에서 운용하던 실제 154kV 변압기 부싱을 대상으로 30tonf 용량의 진동대를 이용하여 진동시험이 실시되었다. 진동시험은 동특성분석시험과 내진성능시험 그리고 파괴한도시험으로 구분하고, 각각의 시험에는 정현소인파, 인공지진파 그리고 연속공진정현파를 진동대운동으로 입력하였다. 이 논문에는 시험에 사용된 시편과 진동설비의 특성 그리고, 시험 방법 및 종류를 설명하고, 시험 결과 얻어진 계측자료의 특성에 대하여 논의한다. 이 연구를 통하여 국내에서 운용중인 154kV 변압기 부싱은 그 고유진동수가 20Hz 이상인 고진동수 설비이며, 감쇠비는 4%미만인 것으로 분석되었다. 또한, 특별한 경우를 제외하고, 변압기 부싱은 국내의 설계기준지진에 대하여 충분한 내진안전성을 보유하고 있으며, 강한 공진운동에 의해 예상되는 부싱의 최초 파괴모드는 하단 개스킷의 파손인 것으로 밝혀졌다.

154[KV] 가공송전선로 아래에서 전장분포의 측정과 분석 (Measurement and Analysis of Electric Filed Distributions under 154[kV] Overhead Tranamission Lines)

  • 이복희;이정기;안창환;이경옥;박동화;곽희로;송진호
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.92-98
    • /
    • 1997
  • 본 노문에서는 154[kv] 가공송전선로의 주변에서 발생하는 극저주파 영역(ELF)의 전장의 측정·분석한 결과에 대해서 기술하였다. 상용주파수와같은 저주파 성분의 검출을 3차원 평행평판형 전장센서를 제작하였으며, IEEE에서 추천하는 실험방법을 적용하여 교정실험을 수행한 바 제작된 전계측정장치의 수파수 대력은 7[Hz]에서 2.7[MHz]이고, 응답 감도는 0.0094[mV/V/m]이었다. 154[kv] 2회선 가공송전선로 아래에서 전장의 실측실험을 수행하고, 그 결과를 분석하였다. 가공송전선 아래에서 의전장의 분포는 주변의 금속 물체 때문에 비대칭 형상을 나타내었으며, 그리고 최대 전계의 세기는 3[kV/m]이하이었다. 본 연구에서의 측정 결과는 관련 여러 국제기관의 제한·권고치를 만족시키고 있다.

  • PDF