• Title/Summary/Keyword: 100미터

Search Result 333, Processing Time 0.03 seconds

High Frequency Magnetic Characteristics of $Co_{90}Fe_{10}$ Thin Films and $Co_{90}Fe_{10}/SiO_2$ Multilayers ($Co_{90}Fe_{10}$ 박막 및 $Co_{90}Fe_{10}/SiO_2$ 다층박막의 고주파 자기특성)

  • 윤의중;진현준;박노경;문대철;김좌연
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.300-307
    • /
    • 1998
  • The $Co_{90}Fe_{10}$ single layer films were deposited on various substrates (glass, Si, polymide) using high vacuum RF magnetron sputtering system and nominall 1000 $\AA$ thick $Co_{90}Fe_{10}$ alloy films had a good high frequency characteristic. $M_S$ and $H_{an}$ values obtained from the B-H characteristic of the $10{\times}[100 nm \;Co_{90}Fe_{10}/100 nm\; SiO_2]$ multilayers agreed well with those obtained by calculation. Complex relative permeability $(={\{\mu}_r={\mu}_r',-j{\mu}$\mu$_r")$ at frequency f was measured from the transmission characteristics $(S_{11},\; S_{21}\;parameters)$ of the microstrip line which has a stacked structure consisting of sample magnetic films and a conductor and is connected to a network analyzer. The ${\mu}_r'-f$ characteristic was abtained from the megnetic absorption, which was analyzed from the S-parameter characteristics of the microstrip line. The ${\mu}_r'-f$ characteristic was also calculated from the ${\mu}_r"-f$-f characteristic using the Kramers-Kronig relation. The measurement results were confirmed to agree well with those obtained by calculations.culations.

  • PDF

Noise Reduction on Low Tube Voltage CT Images (저관전압 CT영상에서 발생되는 노이즈 제거)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • To reduce the exposure dose in head CT, the use of low tube voltage is required. However, increasing noise may cause errors in the second data processing. In this study, we proposed a method to reduce noise by using low tube voltage. Experimental results show that the noise level is high at 100kVp and lowest at 140 kVp. The dose was lower at 100 kVp and higher at 140 kVp. As a result of applying the wavelet according to the threshold value, the noise value in the wavelet Th30 decreased to 4.51. Using the parameter condition(100 kVp, rotation time 0.5 sec, dose: 40.64 mGy) and the wavelet Th 30, the dose reduction of 65.3% was possible. We believe that applying the proposed method to head CT images will help to patient safety and interpret accurate information.

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

Adsorption Equilibrium, Kinetics and Thermodynamic Parameters Studies of Bismarck Brown R Dye Adsorption on Granular Activated Carbon (입상 활성탄에 대한 비스마르크 브라운 R 염료의 흡착평형, 동력학 및 열역학 파라미터에 관한 연구)

  • Lee, Jong-Jib
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.327-332
    • /
    • 2013
  • Batch experiments were carried out for adsorption equilibrium, kinetics and thermodynamic parameters of the brilliant brown R onto granular activated carbon. The operating variables studied were the initial dye concentration, contact time and temperature. Experimental equilibrium adsorption data were fitted to Langmuir and Freundlich adsorption isotherm by linear regression method. The equilibrium process was well described by Freundlich isotherm model and from the determined separation factor (1/n), granular activated carbon could be employed as an effective treatment for the removal of bismarck brown R. From kinetic experiments, the adsorption processes were found to confirm the pseudo second order model with a good correlation and the adsorption rate constant ($k_2$) increased with increasing adsorption temperature. Thermodynamic parameters like the activation energy, change of Gibbs free energy, enthalpy, and entropy were also calculated to predict the nature of adsorption in the temperature range of 298~318 K. The activation energy was determined as 8.73 kJ/mol for 100 mg/L. It was found that the adsorption of bismarck brown R on the granular activated carbon was physical process. The negative Gibbs free energy change (${\Delta}G$ = -2.59~-4.92 kJ/mol) and the positive enthalpy change (${\Delta}H$ = +26.34 kJ/mol) are indicative of the spontaneous and endothermic nature of the adsorption process.

The Effects of Locational Point Representation of Apartment Complexes on Hedonic Valuation of Air Quality (공동주택 위치표현 방법이 대기질의 한계잠재가격 측정에 미치는 영향)

  • Chul Sohn
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.6
    • /
    • pp.949-960
    • /
    • 2003
  • The marginal implicit price of air quality can be measured by taking a partial derivative of hedonic price function (HPF) with respect to the level of air quality. It has been pointed out that the size of the marginal implicit price varies with the use of different function forms, different estimation methods, and the different ways of measuring air quality level in estimating HPF. In addition to these factors, this study shows theoretically and empirically the way housing properties are represented on a digital map could differentiate the size of marginal implicit price of air quality when GIS is used to measure location attributes of the housing properties in the Korean apartment market. Furthermore, this study shows that the degree of difference in the marginal implicit price due to the manner in which housing properties are represented on a digital map can be larger than the degree of difference in the marginal implicit price due to using different function forms and estimation methods. The major implication from the results of this study is that one should carefully try diverse ways of representing housing properties in the Korean apartment market on a digital map in the process of estimating HPF, as he or she usually tries diverse function forms and estimation methods, to see if the value of the marginal implicit price of air quality varies substantially.

The Langmuir Adsorption Isotherms of the Electroadsorbed Hydrogens at the Single Crystal Pt(100)/Aqueous Electrolyte Interfaces (단결정 Pt(100)/수용액 계면에서 전가흡착된 수소의 Langmuir흡착등온식)

  • Chun Jang Ho;Jeon Sang Kyoo
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.1
    • /
    • pp.14-20
    • /
    • 2001
  • The Langmuir adsorption isotherms of the under-potentially deposited hydrogen (UPD H) and the over-potentially deposited hydrogen (OPD H) at the single crystal Pt(100)/0.5 M $H_2SO_4$ and 0.5 M LiOH aqueous electrolyte interfaces have been studied using the phase-shift method. The phase-shift profile $({-\varphi}\;vs.\;E)$ for the optimum intermediate frequency can be used as a useful method to estimate the Langmuir adsorption isotherm $(\theta\;vs.\;E)$ at the interfaces. The equilibrium constant (K) for the OPD H and the standard free energy $({\Delta}G_{ads})$ of the OPD H at the Pt(100)/0.5M $H_2SO_4$ aqueous electrolyte interface are $1.5\times10^{-4}$ and 21.8 kJ/mol, respectively. At the Pt(100)/0.5 LiOH aqueous electrolyte interface, K transits from 1.9(UPD H) to $6.8\times10^{-6}$(OPD H) depending on the cathode potential (E) and vice versa. Similarly, ${\Delta}G_{ads}$ transits -1.6 kJ/mol (UPD H) to 29.5 kJ/mol (OPD H) depending on E and vice versa. The transition of K and ${\Delta}G_{ads}$ is attributed to the two distinct adsorption sites of the UPD H and OPD H on the Pt(100) surface. The UPD H and the OPD H at the Pt(100) interfaces are the independent processes depending on the H adsorption sites rather than the sequential processes for the cathodic $H_2$ evolution reactions.

Bioequivalence Evaluation of Fleroxacin Tablets in healthy Korean (플레록사신정의 생물학적 동등성 평가)

  • Lee, Myong-Jae;Sun, Yih Hsiu;Sohn, Uy-Dong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.18 no.2
    • /
    • pp.132-136
    • /
    • 2008
  • 생물학적동등성시험기준에 따라 플레록사신정 (Fleroxacin, 100 mg) 을 시험약으로 하고 메가로신정 100 mg을 대조약으로 하여 $2{\times}2$ 교차 시험법에 따라 건강한 성인 지원자 24명에게 3정 (fleroxacine, 300 mg/정) 씩을 경구투여한 후, 각 피험자들의 혈중 약물농도 데이터로부터 구한 혈중농도-시간곡선하면적 (AUCtmax.) 과 최고혈중농도 (Cmax) 등의 생체이용률 파라미터에 대해 통계학적으로 고찰하여 두 제제간의 생물학적동등성을 평가하였다. 혈중 약물농도는 HPLC/UV 검출기로 분석하다. 플레록사신정의 대조약과 시험약에 대한 동등성 여부를 종합적으로 판단하여 보면 생물학적동등성시험의 판단 기준인 2항목 (AUCt, Cmax) 에 대하여 두 가지 비교항목 중 AUCt 값의 경우 대조약은 $44.26{\pm}7.12{\mu}g{\cdot}hr/mL$, 시험약은 $4.11{\pm}1.63{\mu}g/mL$이며 두 약물의 로그변환한 평균치 차의 90% 신뢰구간은 log 0.9570 에서 log 1.0565 이다. Cmax 값의 경우 대조약은 $45.16{\pm}10.04{\mu}g{\cdot}hr/mL$, 시험약은 $3.78{\pm}1.01{\mu}g/mL$ 이며, 대조약과 시험약의 로그변환한 평균치 차의 90% 신뢰구간이 log 0.8369에서 log 1.0626 로서, AUCt 와 Cmax 두 항목 모두 log 0.8에서 log 1.25 이내이어야 한다는 생물학적동등성시험 기준을 충족시켰다. 이러한 결과들로부터, 시험약 플레록사신정 (Fleroxacin, 100mg)은 대조약인 메가로신정 100 mg 대하여 생물학적동등성의 판단 기준인 두 항목 AUCt와 Cmax에 있어서 생물학적으로 동등함을 알 수 있었다.

  • PDF

Power Consumption Analysis of Sensor Node According to Beacon Signal Interval in IEEE 802.15.4 Wireless Star Sensor Network (IEEE 802.15.4 무선 스타 센서 네트워크에서 비콘 신호 주기에 따른 센서 노드 전력소모량 분석)

  • Yoo Young-Dae;Choi Jung-Han;Kim Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9B
    • /
    • pp.811-820
    • /
    • 2006
  • In this paper, The correlation of the power consumption of sensor node is analyzed according to the analyze parameter in IEEE 802.15.4 star sensor network. And It is studied the influence on analysis parameter. The power consumption of sensor network in transmission process and average transmission power consumption drives to numerical formula. And CSEM WiseNET system measurement value is used. As a simulation result, The power consumption of sensor node in star network consist of 10 sensor nodes is more than 20 % that in single network in average. When beacon signal interval is 0.1 second in all frequency bands, the power consumption of sensor node in up-link is more than 2.5 times that in down-link in average. When beacon signal interval is 1 second and the number of sensor nodes increases to 100 and sensing data increases to 100 byte, the power consumption of sensor node increases to 2.3 times. And The superior performance of 2.4 GHz frequency band has than 868/915 MHz frequency band up to $6{\sim}12$ times.

Dependence of Analog and Digital Performance on Carrier Direction in Strained-Si PMOSFET (Strained-Si PMOSFET에서 디지털 및 아날로그 성능의 캐리어 방향성에 대한 의존성)

  • Han, In-Shik;Bok, Jung-Deuk;Kwon, Hyuk-Min;Park, Sang-Uk;Jung, Yi-Jung;Shin, Hong-Sik;Yang, Seung-Dong;Lee, Ga-Won;Lee, Hi-Deok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.23-28
    • /
    • 2010
  • In this paper, comparative analysis of digital and analog performances of strained-silicon PMOSFETs with different carrier direction were performed. ID.SAT vs. ID.OFF and output resistance, Rout performances of devices with <100> carrier direction were better than those of <110> direction due to the greater carrier mobility of <100> channel direction. However, on the contrary, NBTI reliability and device matching characteristics of device with <100> carrier direction were worse than those with <110> carrier direction. Therefore, simultaneous consideration of analog and reliability characteristics as well as DC device performance is highly necessary when developing mobility enhancement technology using the different carrier direction for nano-scale CMOSFETs.

Quaternary D Flip-Flop with Advanced Performance (개선된 성능을 갖는 4치 D-플립플롭)

  • Na, Gi-Soo;Choi, Young-Hee
    • 전자공학회논문지 IE
    • /
    • v.44 no.2
    • /
    • pp.14-20
    • /
    • 2007
  • This paper presents quaternary D flip-flop with advanced performance. Quaternary D flip-flop is composed of the components such as thermometer code output circuit, EX-OR gate, bias inverter, transmission gate and binary D flip-flop circuit. The designed circuit is simulated by HSPICE in $0.35{\mu}m$ one-poly six-metal CMOS process parameters with a single +3.3V supply voltage. In the simulations, sampling frequencies is measured around 100MHz. The PDP parameters and FOM we estimated to be 59.3fJ, 33.7 respectively.