• Title/Summary/Keyword: 휨강성 감소

Search Result 99, Processing Time 0.036 seconds

Flexural Rigidity Reduction of Multi-Delaminated Composite Beams (다층 층간분리된 복합적층보의 휨강성 감소)

  • Park, Tae-Hyo;Baek, Jae-Wook;Cho, Baik-Soon
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.3
    • /
    • pp.233-244
    • /
    • 2001
  • In this study, flexural rigidity reduction of multi-delaminated composite beams are investigated. In order to evaluate the flexural rigidity reduction. Performed theoretical analysis. In order to investigate flexural rigidity reduction about effects of delamination on composite beams, the general kinematic governing equations are derived and solved by dividing the delaminated beam and imposing the continuity conditions into each sub-beam. For condition to appear multiple delamination through the laminated composite beams, the flexural rigidity reduction are compared according to many stacking sequences and several forms for delaminations. The present study could be used to evaluate the flexural rigidity reduction of composite laminated beams on multi-delaminations.

  • PDF

Effects of Axiral Restraint on flexural and Shear Behavior in High Strength Reinforced Concrete Beams (고강도 철근 코크리트 휨 부재의 휨.전단거동에 미치는 축방향 구속의 영향)

  • 양은익;고훈범;김진근;이성태
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.6
    • /
    • pp.207-216
    • /
    • 1997
  • 본연구는 축방향 변형 구속이 고강도 콘크리트 휨부재의 휨 전단거동에 미치는 영향을 조사하기 위한 것으로, 수화열과 건조수축에 기인하는 축방향 변형과 재하에 의한 축방향 변형을 구속한 부재 및 무구속 부재에 대하여 휨파괴와 전단파괴 실험을 실시하였다. 타설 직후부터 축변형을 구속한 실험체의 재하시 강성은 재하전의 구속으로 발생한 관통균열의 영향을 받아 무구속 실험체의 강성보다 낮지만, 재하시의 축변형 구속에 따른 압축구속력의 상승으로 인하여 강성의 크기는 역전되었다 축변형이 완전히 구속된 휨부재의 휨강도는 무구속 부재보다 20%이상 상승하지만 변형능력은 감소하는 것으로 나타났으며, 재하전의 축변형 구속에 의한 관통균열(균열폭 0.1mm 미만)은 부재의 전단내력 및 전단균열 진전 형상에 영향을 미치지 않았다.

Flexural Behavior of RC Beam After Completion of Electrochemical Chloride Extraction (전기화학적 염화물 추출 후 철근-콘크리트 보의 휨 거동)

  • Jung Wook Lee;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.484-492
    • /
    • 2023
  • The structural behaviour of concrete beam was examined by the three points bending test after the completion of the electrochemical chloride extraction (ECE), rather than bond strength mostly measured in previous studies. It was found that the flexural rigidity of concrete was lowered by the ECE, but the strength was enhanced in terms of the maximum load.The flexural rigidity, in the linear elastic range, was reduced by the loss of effective cross-section area. In fact, the inertia moment was substantially subjected to 70 % loss of the cross-section by the tensile strain at the condition of the failure. However, a lower rate of the inertia moment reduction was achieved by the ECE, implying the higher resistance to the cracking, but the higher risk of deformation.

Flexural Stiffness and Characteristics of Vibration in CFT Truss Girder (CFT 트러스 거더의 휨강성 및 진동특성)

  • Chung, Chul-Hun;Song, Na-Young;Kim, In-Gyu;Jin, Byeong-Moo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.19-30
    • /
    • 2009
  • The primary objective of the present study was to attempt to quantify the effect of the existing codes for CFT composite section on initial section flexural stiffness, based on the measured vibration frequency of CFT truss girders. The formulae for the initial flexural stiffness of the composite sections in the different codes are compared with the free vibration test results. The results of the free vibration test on the CFT truss girders are in good agreement with the analysis results when used in ACI formulae. The free vibration analysis of CFT truss girders for different f/L ratios was conducted to determine how the natural frequency of the CFT truss girder is affected by different f/L ratios. The presence of the f/L ratios in CFT truss girders alters its frequencies of vibration because of the global stiffness of the CFT girders. The frequency in horizontal modes decreases as the f/L ratio increases. However, the frequency in vertical modes increases as the f/L ratio increases.

Evaluation of the Bending Performance of a Modified Steel Grid Composite Deck Joint (격자형 강합성 바닥판의 수정된 이음부에 대한 휨성능 평가)

  • Shin, Hyun-Seop;Park, Ki-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.38-47
    • /
    • 2013
  • For the joint connection of the precast steel grid composite decks, the prefabricated joint which is composed of concrete shear key and high-tension bolts was already proposed. In this study, for the purpose of increasing the bending stiffness and bending strength of the proposed prefabricated joint section details of the proposed joint are modified, and through experimental tests the bending performance, such as stiffness and strength of a modified joint, is compared with those of the proposed joint. Test and analysis results show that the shear cracks in the concrete shear key are clearly reduced by the strengthening of the shear key using shear studs and additional rebars. According to analysis results of the moment-curvature relationship, bending stiffness of the modified joint is about 47% greater than the stiffness of the proposed joint. Furthermore, the modified joint has about 32% greater bending strength than the proposed joint. Compared to specimens without the joint the modified joint has same or slightly higher bending strength, but about 37% lower bending stiffness.

A Study on Flexural Rigidity of Two-row Overlap Pile Wall for Deep Excavation Support (대심도 굴착면 지지를 위한 2열 겹침말뚝의 휨 강성에 관한 연구)

  • Choi, Won-Hyuk;La, You-Sung;Kim, Bum-Joo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.1
    • /
    • pp.33-43
    • /
    • 2018
  • Two-row Overlap Pile wall is a novel retaining wall system with high flexural rigidity and waterproofing for deep excavation support currently being developed in Korea. The Two-row Overlap Pile wall is constructed by making an overlap between consecutive four-axis (or two-axis) auger piles which themselves are overlapped and arranged in zigzag manner. In this study, the flexural rigidity of the Two-row Overlap Pile wall, including the effect of cross-sectional shape, was examined using both theoretical and numerical approaches. The results of investigation suggested that the Two-row Overlap Pile wall formed with two-row piles exhibit greatly higher flexural rigidity than conventional one-row pile walls such as Cast in place pile (CIP) and Secant pile wall (SPW), whereas the effect of overlap length between piles on the flexural rigidity is relatively minimal.

A Study on Rotation Behavior of High Strength Steel Endplate Connections under Fire (화재시 고강도강 엔드플레이트 접합부의 회전 거동에 관한 연구)

  • Shin, Su-Min;Lee, Chy-Hyoung;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.35-43
    • /
    • 2016
  • In order to understand rotation behavior of high strength steel endplate connections under fire, this study is compared with existing studies conducted using FEA program. Eurocode 3 presents the three failure modes according to the prediction of bending resistance moment. The parameters of analysis model are temperature, thickness and steel materials of endplate. The rotation stiffness, and bending resistance moment are analyzed according to the parameters. The change of rotation stiffness and bending resistance moment are analyzed about the parameters, regression equations are suggested the change of high strength steel endplate connections. Consequently, the regression equations were proposed as the linear and quadratic equation. The moment ratio of high strength steel under fire was more reduced than the carbon steel, and was small effect about the thickness. When the high strength steel under fire was compared with at ambient temperature, the slope of initial rotation stiffness reduced, the increment ratio of moment was slow, and the change of plastic rotation stiffness wasn't effect by the thickness increase.

Structural Performance Evaluation of Reinforced Concrete Beams with Externally Bonded FRP Sheets (RC 구조물에 적용된 부착식 휨보강공법의 보강성능 평가)

  • Hong, Geon-Ho;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.78-86
    • /
    • 2003
  • Reinforced concrete beams are often retrofitted with various FRP composite sheets. This paper is focused on the comparison of structural performance of various FRP sheets and proposal of the retrofitting design formula. Effects of the FRP kinds(AFRP, GFRP, CFRP) and the reinforcing steel ratio on behavior of the retrofitting beams are tested and analyzed with particular emphasis on the maximum load capacity, stiffness, and ductility. The experimental work included 4 point flexural testing of 3.2m span reinforced concrete beams with bonded external reinforcements. The results show that the difference of FRP kinds is not large and the flexural load capacity is mainly affected by stiffness of the retrofitting materials. This paper also proposes the design formula on the retrofitting reinforced concrete flexural members and checks with this experimantal work and previous research results.

Calculation for of Strength Reduction Factor for Concrete Beam reinforced with GFRP rebars (GFRP rebar로 보강된 콘크리트보의 휨 강도감소계수 보정식 제안)

  • Sim, Jong-Sung;Park, Cheol-Woo;Park, Sung-Jae;Kang, Tae-Sung;Kwon, Dong-Wook;Lee, Yong-Taek
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.137-140
    • /
    • 2008
  • If the flexural member of concrete is designed using the FRP rebar, suddenly brittleness destruction resulted from the fracture of FRP rebar is generated in the extreme situation because of brittleness characteristics of FRP rebar and concrete when designed to be less than balanced reinforcement ratio, so it is recommended to design the flexural member of concrete to be more than balanced reinforcement ratio. In ACI 440.1R-06 proposes the different bending strength decrease coefficient according to destructive form of concrete flexural member using the FRP rebar. However, ACI 440.1R-06 applies the same strength decrease coeffient to all FRP rebars made of diverse materials. If the same strength decrease coefficient is applied to all FRP rebars, effect of increasing the reinforcement ratio and selection of FRP rebar will be considerably limited. In this regard, we are to propose the formula to calculate the bending strength decrease coefficient in consideration of change in characteristics of FRP rebar and L/D through the reliability analysis in this paper.

  • PDF

Modal Property Estimation of Tapered Cantilever Pipe-type Cracked Beam (테이퍼 캔틸레버 원형강관 균열보의 모드특성 추정)

  • Lee, Jong Won;Kim, Sang Ryul;Kim, Bong Ki
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.361-368
    • /
    • 2014
  • Modal properties for tapered cantilever pipe-type beam is identified by applying the boundary conditions to a general solution for tapered beam. A bending stiffness for cracked beam is constructed based on an energy method for tapered cantilever thin-walled pipe, which has a through-the-thickness crack, subjected to bending. Then the natural frequencies and mode shapes of a tapered cantilever thin-walled cracked pipe are identified. It can be found that the phenomenon of the bending stiffness distribution along the beam length of the cracked beam is quite reasonable, the natural frequencies are decreased as the crack sizes are increased, and the mode shapes are changed due to the crack. This results may be used to the vibration-based crack identification for the tapered cantilever pipe-type tower structures.