• Title/Summary/Keyword: 휘발성유기오염물질

Search Result 95, Processing Time 0.024 seconds

Insights Of Air Pollutant Emission From Construction Sealant (건축용 실란트 오염물질 방출량 기준에 대한 고찰)

  • Seo, Yeonwon;Jung, Jinyoung;Bae, Keesun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.226-227
    • /
    • 2014
  • This study is intended for the review of the standards related with the released contaminants from building materials used in the building room. Because currently being used industry standard and test method for the emissions of air pollutant are ambiguous so the new enactment and revision of the test methods and standards need to be addressed to match the actual situation in the construction industry. Based on actual evaluation for seveal sealants used in the job site, this study will present a direction for the revision and new enactment of standards and test method appropriately.

  • PDF

The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House (에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성)

  • Yoo, Bok-Hee;Park, Sun-Hyo
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.

A Study of Pollutants emitted from Apartment finishing Materials (공동주택 건축마감자재 오염물질 방출에 관한 연구)

  • Kim, Min-Woo;Lee, Chung-Keun;Hwang, Dong-Gyu;Lee, Seong-Yeun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.981-985
    • /
    • 2008
  • Construction company's role is getting bigger recently because of interest of indoor air quality problem. The using environment-friendly building finishing material is the most benefit method to reduce pollutants in house. It is confirmed the actual condition of environment-friendly building finishing material such as wallpapers, wooden flooring boards, glues, paints, adhesives, plaster boards that are used the work of apartment construction in 2006-2007. It shows that environment-friendly materials have excellent grade mostly, general materials have pass I, pass II grade mostly and are high TVOC emission.

  • PDF

A study on contaminant reduction performance of the adsorption protector for construction surface (흡착보양재의 오염물질방출 저감성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.714-719
    • /
    • 2008
  • In a domestic construction field, after floor is constructed, protector for construction surface is set up to prevent the surface of the floor being scratched and polluted. However, the problem is that contaminants discharged with the removal of the protector for construction surface exert a bad influence for the indoor air quality. In the research, it tested to the contaminant reduction performance of the adsorption protector for construction surface using powder of charcoal by the alternative proposal of such protectors for construction surface

  • PDF

A Study on Initial Control Performance of the Adsorption Protector for Construction Surface about Contaminant (흡착보양재 적용에 따른 실내 오염물질 초기제어 성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.229-235
    • /
    • 2009
  • In a domestic construction field, floor surface must be covered not to be scratched and polluted by protector until resident comes in. However this protector restricts the contaminant to leave from floor surface. So when the protector is removed, much contaminant is emitted from the floor surface to inside and makes a bad influence on the indoor air quality, In this research, it will be tested the reduction performance of contaminant between a normal protector and a contaminant absorption protector using charcoal powder.

Development of Nontoxic Flame Retardant Paint (친환경 무독성 난연도료에 대한 연구)

  • Do, Young-Woong;Kwon, Myeon-Joo;Joo, Hyun-Ku;Yoon, Jae-Kyung;Ha, Jin-Wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.336-338
    • /
    • 2008
  • 본 연구에서는 EU에서 발효되는 6대 규제유해물질(Pb, Hg, Cd, $C^{6+}$, PBB/PBDE)과 환경부 규제유해물질에 의해 도료의 유해조성물질을 제한하게 됨에 따라 VOC(휘발성유기화합물) 배출이 적고, 브롬계/할로겐계를 탈피하여 인체안전성 확보 및 환경오염을 최소화하며, 방염제 형식승인 및 검정기술기준 (KOFEIS 0201)에 부합하는 수용성 유 무기계 난연도료를 개발하였다. 친환경적인 난연도료 제조에 대한 최적조건으로 Mg(OH)$_2$, $Sb_2O_3$, 붕산아연을 1:2:2로 혼합한 난연제 그리고 바인더(마이셸 2%)와 물의 비율을 1:1로 제조한 후, 난연제:(바인더+물)을 1:1로 제조한 난연도료 3의 성능이 가장 우수하였다.

  • PDF

Characteristics of Hazardous Air Pollutants in the Steel Industrial City, Pohang (II) - Volatile Organic Compounds (철강산업도시 포항지역 유해대기오염물질의 오염특성 (II) - 휘발성유기화합물)

  • Kim, Min-ji;Seo, Young-Kyo;Cho, Byoung-Yoon;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.244-258
    • /
    • 2018
  • We performed this study to investigate the spatial, seasonal, and daily variations of the concentrations of volatile organic compounds (VOCs) in Pohang, where large steel industrial complexes are located. Ambient air sampling was undertaken at 4 sites during 4 seasons. Each sample was taken for 4 hours continuously for 8 consecutive days per season at each site. Three sites were located within the Pohang city, but one as a control site in Gyeongju. A total of 72 individual VOCs were determined by thermal desorption coupled with GC/MS, including aliphatics, aromatics, carbonyls and halides. The most abundant VOC was toluene, being followed by ethylbenzene and xylenes. Benzene concentrations(c.a. 0.7 ppb) were found to be much lower than the national ambient standard of 1.5 ppb. Overall, the VOCs levels in Pohang appeared to be lower than other national industrial complexes in Korea such as Shiwha-Banwol, Yeosu-Gwangyang, Gumi, and Ulsan. This implies that steel industry may not give significant impacts on the atmospheric levels of VOCs as much as petrochemical, electronic, and/or textile industries, where large amounts of organic solvents are used.

Seasonal variations of volatile organic compounds (VOCs) in indoor air of daycare centers (보육시설 실내공기 중 휘발성유기화합물(VOCs)의 계절적 농도변화에 대한 연구)

  • Jang, Seong-Ki;Chun, Jae-Young;Kim, Sung-Youn;Park, Suk-Young;Ryu, Jung-Min;Lim, Jung-Yeon;Lee, Woo-Suk
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.474-482
    • /
    • 2007
  • Daycare centers are an important indoor environment for pre-school children and exposure area with potential harmful health effects for infants and children who spend most of their daily life. Sampling was undertaken at 29 daycare centers located Seoul in Korea from January, 2006 to December 2006. The target compounds were 7 individual volatile organic compounds (benzene, toluene, ethylbenzene, m,p-xylene, styrene, o-xylene, TVOC). The mean concentrations of TVOC, toluene, m ,p-xylene, ethylbenzene, benzene and styrene in daycare centers were $318.7{\mu}g/m^3$, $51.6{\mu}g/m^3$, $11.7{\mu}g/m^3$, $6.5{\mu}g/m^3$, $4.2{\mu}g/m^3$, $3.6{\mu}g/m^3$, respectively. Toluene occupied 17.6 % of the concentration of individual VOCs. The ratio of indoor and outdoor (I/O) of TVOC and toluene were 2.0 and 1.6, respectively. The results of characteristics according to a season of a year, the concentration of TVOC were measured $433.9{\mu}g/m^3$, and these concentrations during third quarter of the year in summer were higher than the other season. In the other four seasons, TVOC were measured 280.5 in winter, 298.3 in spring and $264.6{\mu}g/m^3$ in fall, respectively.

A Study on Adsorption Characteristics of Benzene over Activated Carbons Coated with Insulating Materials and Desorption by Microwave Irradiation (절연물질이 코팅된 활성탄의 벤젠 흡착특성 및 마이크로파에 의한 탈착에 관한 연구)

  • Kim, Ki-Joong;Ahn, Ho-Geun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.445-451
    • /
    • 2008
  • In order to regenerate the activated carbon polluted by volatile organic compounds (VOCs) using microwave, adsorption and desorption characteristics of benzene over activated carbon (AC) coated with insulating materials were investigated. Physical characteristics of activated carbon and insulator-coated ACs were investigated by means of $N_2$ gas adsorption and scanning electron microscopy (SEM). The amount of VOC adsorbed showed a positive relationship with the specific surface area of the ACs, and spark discharge over insulator-coated ACs did not occur. Potassium silicate (PS) was the best binder for coating of insulating materials on AC. Amount of benzene desorbed by microwave irradiation was dependent on output power of microwave. Nearly same performance was obtained even though the adsorption-desorption operation under microwave irradiation was repeated 5 times. Finally, it was known that the microwave heating was a very effective mean for regenerating the polluted AC.

Energy Usage and Emissions of Air Pollutants in North Korea (북한 에너지 사용과 대기오염물질 배출 현황)

  • Kim, In-Sun;Lee, Ji-Yi;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.303-312
    • /
    • 2011
  • Data on the energy usage including biomass, emissions of air pollutants ($SO_x$, $NO_x$, CO), and the air quality in North Korea are analyzed. The energy usage in North Korea has decreased in the 1990s and thus, the emission amount of air pollutants. Coal and biomass constitute a major fraction of energy sources since the 1990s. It is identified that the emission amount of air pollutants per unit energy consumption in North Korea is much higher than South Korea for the period data are available (since 1990) implying that the air pollutant emission management system in North Korea is inadequate. In particular, the amount of biomass burning for household cooking and heating is significant with the huge emissions of air pollutants such as CO and organic species both in the gas and aerosol phase. Furthermore, it is found that the existing energy usage and air pollutant emission data are not consistent in biomass burning related data.