The Growth Response of Balloon Flower (Platycodon grandiflorum A. DC.) Plantlets In Vitro as Affected by Air Exchanges and Light Intensity (배양용기 내 환기와 광도에 따른 도라지(Platycodon grandiflorum A. DC.) 기내 배양묘의 생장반응)

  • Choi So-Ra;Kim Myung-Jun;Eun Jong-Seon;Ahn Min-Sil;Lim Hoi-Chun;Ryu Jeong
    • Journal of Plant Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.23-29
    • /
    • 2005
  • Shoots of balloon flower (Platycodon grandiflorum A. DC.) derived from in vitro germinated seeds were cultured on MS medium containing $0.1\;\cal{mg/L}$ NAA under various photosynthetic photon flux (PPF) 33, 66, and $99\;{\mu}mol\;m^{-2}s^{-1}$ with or without membrane filter. Number of air exchanges per hour (NAEH) of the culture vessel with membrane filter on the lid was $4.9 h^{-1}$ and that without membrane filter was $0.1 h^{-1}$ Plantlets grown in $4.9 h^{-1}$ NAEH showed greater growth than in $0.1 h^{-1}$ NAEH. According to increase of PPF, plantlets growth decreased in $0.1 h^{-1}$ NAEH while it increased in $4.9 h^{-1}$ NAEH. At the same PPF, fresh weight and sugar content in plantlets in $4.9 h^{-1}$ NAEH were above 1.9, 2.0 times higher than those in $0.1 h^{-1}$ NAEH, respectively. Also they were enhanced in $4.9 h^{-1}$ NAEH by increase of PPF whereas no significance in $0.1 h^{-1}$ NAEH. The percentage of water content of plantlets in $4.9 h^{-1}$ NAEH was $4.2\~5.5\%$ lower than those in $0.1 h^{-1}$ and no difference in PPF. The content of total chlorophyll in plantlets in $4.9 h^{-1}$ NAEH was higher $0.27\~0.79\;\cal{mg/g}$ F.W. than that in $0.1 h^{-1}$ NAEH. By increase of PPF, it was decreased in $0.1 h^{-1}$ NAEH while had no significant difference in $4.9 h^{-1}$ NAEH. Guard and subsidiary cells of leaves in $4.9 h^{-1}$ NAEH were more developed than in $0.1 h^{-1}$ NAEH. Especially, in $99\;{\mu}mol\;m^{-2}s^{-1}$ leaves in $0.1 h^{-1}$ NAEH had undeveloped subsidiary cells and wide open stomata whereas those in $4.9 h^{-1}$ NAEH had well-developed subsidiary cells.

Diffusion Characteristics Based on the Gas Leakage Direction and Air Change per Hour in a Enclosed Space on Board a Ship (밀폐된 선내 공간에서 가스 누출방향과 환기횟수에 따른 확산특성)

  • Seong Min Lee;Ha Young Kim;Byeol Kim;Kwang Il Hwang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.165-175
    • /
    • 2024
  • Hydrogen is being touted as one of the energy sources to combat the climate change crisis. However, hydrogen can leak into enclosed spaces, rise to the ceiling, accumulate, and cause fires and explosions if it encounters an ignition source. In particular, ships that transport hydrogen or use it as a fuel comprise multiple enclosed spaces. Therefore, the dif usion characteristics within these spaces must be understood to ensure the safe use of hydrogen. The purpose of this study is to experimentally determine the diffusion characteristics of helium, which has similar properties to hydrogen, in a closed space on board a ship, and to determine the change in the oxygen concentration along the leakage direction as the air change per hour(ACH) increases to 25, 30, 35, 40, and 45 through CFD simulation. The study, results revealed that the oxygen concentration reduction rate was 2% for leakage in the -z direction and 1% for leakage in the +x and +z directions, and the ventilation time was 15 min 30 s for leakage in the -z direction, 7 min for leakage in the +x direction, and 9 min for leakage in the +z direction, showing that differences existed in the oxygen concentration and ventilation time depending on the leakage direction. In addition, no significant difference was observed in the rate of oxygen concentration reduction and ventilation time in all leakage directions from the ACH of 35 and above in the experimental space. Therefore, because the oxygen concentration and ventilation time were not improved by increasing the ACH, 35 was noted as the optimal ACH in this experimental environment.

Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests (실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가)

  • Kwag, Byung Chang;Lee, Soo Man;Kim, Gil Tae;Kim, Jong Yeob
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.93-106
    • /
    • 2022
  • Ventilation plays an important role in controlling indoor air quality. Due to the recent spread of infectious diseases such as COVID-19 and with people spending more time indoors, there's been increased attention on the importance of ventilation performance. In many countries, ventilation is regulated by airflow rates and the number of air changes per hour (ACH). However, airflow rates and ACH alone do not provide an accurate account of actual indoor pollutant removal and ventilation uniformity in a space. This study looked into the ventilation performance of an actual residential unit using several sampling points instead of basing it off of airflow and air change rates. Literature review was used to derive relevant influencing factors and the tracer gas dilution method was used for the field test. The study measured air velocity, age of air, and ventilation efficiency at several locations and compared them to the average value at the center of the test space to determine the differences in ventilation performance at the selected measurement points. The study showed that different sampling locations resulted in different ventilation values. Findings of this study will be used to develop an experimental procedure for evaluating indoor ventilation performance of actual residential spaces.

Growth Characteristics of Variety of Oyster Mushroom (Pleurotus ostreatus) as Affected by Number of Air Exchanges (느타리버섯의 품종별 환기횟수에 따른 생육특성)

  • Jang, Myoung-Jun;Ha, Tae-Moon;Lee, Yun-Hae;Ju, Young-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.208-214
    • /
    • 2009
  • In this study, we investigated the effects of the number of air exchanges (NAE) on shape fruit body in two oyster mushrooms, Chunchu 2# and Suhan 2#. The suitable NAEs of Chunchu 2# were $1/10h^{-1}$ at primordial induction, $1/6h^{-1}$ at early stage of growth, $1/4h^{-1}$ at middle stage of growth, $1/4h^{-1}$ at late stage of growth and those of Suhan 2# were $1/6h^{-1}$ at primordial induction, $1/6h^{-1}$ at early stage of growth, $1/4h^{-1}$ at middle stage of growth, and $1/2h^{-1}$ at late stage of growth. In those conditions, the fruit bodies grew well. $CO_2$ concentration hardly affected the primordial formation of both mushrooms. However there were ventilation disturbances over 1500ppm. For instance, the end of pileus rolled up etc. As a result, Suhan 2# required higher ventilation compared with Chunchu 2# and the lower NAE was favorable for growth.

Forced Ventilation Number of Air Changes to Set Point of Inside Air Temperature in Summer Glasshouse (여름철 유리온실의 목표온도 유지를 위한 강제환기 회수)

  • 우영회;이정명;남윤일
    • Journal of Bio-Environment Control
    • /
    • v.4 no.2
    • /
    • pp.223-231
    • /
    • 1995
  • Judicious control of high temperature is the most important task for a successful intensive - cultivation in greenhouses during the hot summer. Therefore, the climatological data at 31 locations in Korea were calculated using the modified model equation for ventilated in glasshouses during summer. Furthermore, the adequate number of air- changes or frequency of ventilation was estimated based on temperature settings, which is considered to be more active means of controlling summer glasshouse temperatures, was investigated. The major results can be summarized as follows: Forced ventilation of one air change per minutes was effective in maintaining the maximum air temperature below 35$^{\circ}C$ in the glasshouse haying 40% shading. It was impossible, however, to maintain air temperature below 3$0^{\circ}C$ in 40% shaded glasshouse with forced ventilation only.

  • PDF

Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse (플라스틱 단동온실의 천창 종류에 따른 자연환기 효과)

  • Rasheed, Adnan;Lee, Jong Won;Kim, Hyeon Tae;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.225-233
    • /
    • 2019
  • In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to $9.6^{\circ}C$ depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to $0.49min^{-1}$. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of $3.2^{\circ}C$ and a maximum ventilation rate of $0.49min^{-1}$.

Effect of $CO_2$ Concentration, NAEH and Light Intensity on the Photoautotrophic Growth of Campanula punctata 'Rubriflora' Plantlets In Vitro (자주초롱꽃의 기내 자가영양배양시 $CO_2$농도, 환기횟수 및 광도가 생장에 미치는 영향)

  • Shim, Jae-Nam;Kim, Gyeong-Hee;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.14 no.4
    • /
    • pp.233-238
    • /
    • 2005
  • Growth of Campanula punctata 'Rubriflora' plantlets, as affected by three levels of photosynthetic photon flux (PPF), 70, 110, and $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, two levels of $CO_2$ concentration, 500 and $1,500{\mu}mol{\cdot}m^{-1}$, and two levels of number of air exchanges per hour (NAEH), 0.1 and $2.8 h^{-l}$, was studied. Explants were obtained from photomixotrophically-micropropagated plantlets. Four explants were planted in each $3.7{\times}10^{-4}m^3$ polycarbonate box containing MS basal medium and no added sucrose. Explants were cultured under cool-white fluorescent lamps for $16h{\cdot}d^{-1},\;at\;25\pm1^{\circ}C$ temperature, and $70\~80\%$ relative humidity In treatments of $2.8h^{-1}$ NAEH, a 10mm round hole made on the vessel cap was sealed with a microporous filter. For higher $CO_2$ concentrations in the culture room, $CO_2$ gas was provided from a tank of liquefied $CO_2$. Fresh and dry weights, length of the longest root, and number of leaves significantly increased with increasing PPF and especially $CO_2$ concentration. Length of the longest root, number of leaves, fresh and dry weights, and chlorophyll concentration were enhanced with increased NAEH. However, leaf area was the smallest in the $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}\;PPF\;2.8h^{-1}$ NAEH and especially, $1,500{\mu}mol{\cdot}mol^{-1}\;CO_2$ concentration treatment. Treatment effect became more produced with time. Overall, treatment with $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}\;PPF\;and\;1,500{\mu}mol{\cdot}mol^{-1}\;CO_2$ gave the most vigorous growth.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (건축물에너지효율등급 기밀시험이 등급에 미치는 영향분석)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Ju, Jung-Kyeong
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • The ventilation frequency of 0.5 times in residential facilities is applied mandatorily to the housing facilities containing more than 100 house units to improve the indoor air quality and create comfortable interior conditions and pleasantness for residents. The Building Energy Efficiency Rating system requires the implementation of leakage test based on ventilation frequency with the test results being reflected in the efficiency ratings, thereby stimulating the precise construction of the fittings in the periphery of windows and savings of energy that can be lost due to the infiltration air. The inspection results of the Building Energy Efficiency Rating at the site showed that the ventilation frequency was in the range between 0.63 and 0.71 and that the difference was found to have a significant effect on the amount of energy reduction. It is urgent to conduct the study on highly leakage-proof buildings and construction methods, along with the expansion of mandatory leakage-proof diagnosis of non-residential buildings, considering the mandatory ventilation frequency below 0.6 for passive houses under the European standards and the target set by Korea to introduce the passive house, the rigorous standard for energy efficiency in buildings and mitigating their ecological footprint, by 2017 and achieve the zero house by 2025.

Evaluation of Changes in Radon Levels in Educational Research Facilities by Number of Ventilation and Time (환기횟수 및 환기시간에 따른 교육연구시설 라돈 수치변화 평가)

  • Shin, Yoon-Seok;An, Jae-Seung;Kim, Seong-Bin;Park, Min-Young
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.335-336
    • /
    • 2023
  • 최근 환경에 대한 관심이 지속적으로 증가함에 따라 실내 공기질에 대한 관심 역시 증폭되었다. 이에 따라 실내 공기질을 결정 짓고 흡연에 이어 폐암 사망률이 높은 라돈에 대한 관심 역시 증가하였다. 따라서 본 연구에서는 실내 라돈가스의 농도를 낮추기 위한 방법을 찾기 위해 RADON EYE RD200을 이용하여 교육연구시설에서의 세 강의동을 대상으로 라돈 방출량을 측정하고, 환기를 통해 라돈의 감소량을 측정한다. 세 강의동 모두 현재 기준치인 148 Bq/m3을 초과하는 수치를 기록하였고, 강의실을 10분간 환기한 결과 1회 환기 시 평균 77 Bq/m3만큼 감소하였고, 2회 환기 시 평균 56 Bq/m3만큼 감소하였다. 본 연구를 통해 라돈의 실태 및 위험성을 인지하고 라돈에 관련된 시설물 지침 및 환기를 강조하는 방안에 대한 마련이 필요하다고 판단된다.

  • PDF