Forced Ventilation Number of Air Changes to Set Point of Inside Air Temperature in Summer Glasshouse

여름철 유리온실의 목표온도 유지를 위한 강제환기 회수

  • 우영회 (원예 연구소 시설재배과) ;
  • 이정명 (경희 대학교 산업대학 원예학과) ;
  • 남윤일 (원예 연구소 시설재배과)
  • Published : 1995.12.01

Abstract

Judicious control of high temperature is the most important task for a successful intensive - cultivation in greenhouses during the hot summer. Therefore, the climatological data at 31 locations in Korea were calculated using the modified model equation for ventilated in glasshouses during summer. Furthermore, the adequate number of air- changes or frequency of ventilation was estimated based on temperature settings, which is considered to be more active means of controlling summer glasshouse temperatures, was investigated. The major results can be summarized as follows: Forced ventilation of one air change per minutes was effective in maintaining the maximum air temperature below 35$^{\circ}C$ in the glasshouse haying 40% shading. It was impossible, however, to maintain air temperature below 3$0^{\circ}C$ in 40% shaded glasshouse with forced ventilation only.

여름철 온실 온도환경의 효율적인 제어는 온실의 주년재배와 고도활용을 위한 가장 중요한 당면과제이다. 따라서 본 연구는 우리나라 31개 지역의 기후자료를 분석하여 고온기 온실의 기온관리에 있어서 목표 온도 유지를 위한 지역별 적정 최대환기횟수를 결정함으로서 온실의 기온관리를 위한 기본적인 자료를 제공하고자 실시하였다. 그 결과 여름철 유리온실의 설정온도 유지를 위한 강제환기는 40% 차광 유리 온실에서 최대환기횟수 1회/min로 35$^{\circ}C$ 유지가 가능하였으나 환기만에 의한 한계 최고실온 3$0^{\circ}C$ 유지는 불가능하였다.