• Title/Summary/Keyword: 환경 진단

Search Result 2,184, Processing Time 0.12 seconds

The Characterization of Mass Transfer Factors in Neuroblastoma Implanted in Immunosuppressed Nude Rats (면역결핍누드쥐에 이식된 neuroblastoma에서의 물질전달에 미치는 인자의 특성)

  • ;G.R
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.41-50
    • /
    • 1994
  • The chemotherapy using macromolecules, i.e., monoclonal antibodies loaded with anticancer agents hasn't been successful in delivering therapeutic amount of the conjugates. The comprehensive evaluation of mass transfer factors in tumor is prerequisite for the development of the effective chemotherapy. Characterization of neuroblastoma implanted in immunosuppressed athymic nude rats was performed. Its growth kinetics, glucose metabolic rate (GMR) were measured along with the interstitial fluid pressure (IFP), blood perfusion rate (BPR) and pH distribution throughtout the tumor radius. Volume doubling time and GMR were 8.1 days(SD 0.44 day), 23.53 mg/min/100 g(SD 3.54 mg/min/100 g), respectively. The IFP in tumor center was increased with tumor volume, and approached to 3 mmHg (SD 2.6 mmHg) when the tumor was 3 cm high. The radial distribution of IFP, BPR and pH in 2 cm high tumors showed that BPR and pH were decreased, while IFP was increased as the ~ensors moved toward the tumor center. The elevated IFP, decreased BPR and pH in tumor center suggested that the delivery of conjugates might be increased by properly manipulating mass transfer factors.

  • PDF

Improvement Plan for Evaluation System of Records Management in Public Institutions : Focused on Introducing Self-evaluation System (공공기관 기록관리 평가제도 개선 방안 자체평가제도 도입을 중심으로)

  • Oh, Myung Jin;Ju, Hyun Mi;Rieh, Hae Young
    • The Korean Journal of Archival Studies
    • /
    • no.65
    • /
    • pp.151-197
    • /
    • 2020
  • The records management evaluation system is a system operated by the National Archives of Korea since 2007 based on the 「Public Records Management Act」. As the environment of public records management changes dramatically, there is a growing perception that fundamental improvement is necessary in the operation of this evaluation system. In particular, it is required that the most emphasized area is the customized methods based on the type and characteristics of the institutions. This study focused on the self-evaluation method, which aims to strengthen the autonomous evaluation capability of institutions as a new records management evaluation system in public institutions. In particular, the needs to change toward the self-evaluation method is described in relation to the diversity of the institutions to be evaluated, the specificity of the organizational structure of the archives, and the hierarchy and individuality of the institutions. A self-evaluation system (draft) was designed by which an institution diagnoses the records management work by itself, which aims to improve the level of performance. It also covered the development of evaluation items and indicators, the step-by-step application, and the legal and operational aspects to run the records management evaluation system in phases in public records management practices.

Effects on EDC-like farming chemicals in aquatic Organism (환경생물에 대한 내분비교란물질 의심 농약의 영향)

  • Kim, Hyun-Woo;Park, Kun-Ho;Park, Jin-Hong;Jin, Hua;Kim, Joon-Seong;Eu, Gook-Jong;Cho, Hyun-Sun;Kang, Ga-Mi;Lee, Myung-Sung;Song, Byung-Hoon;Shin, Jin-Sup;Cho, Maing-Haing
    • The Korean Journal of Pesticide Science
    • /
    • v.7 no.3
    • /
    • pp.188-197
    • /
    • 2003
  • Endocrine disrupting chemicals (EDCs) can alter hormone regulation that control reproductive system in animals. The effects of endosulfan, molinate, and alachlor that suspected to have examined disruption EDCs effect on a fish species of interest, Xiphophorus helleri (swordtail fish), were studied using vitellogenin (Vtg) and aromatase as diagnostic biomarkers. Induction of Vtg proteins was detected by RT-PCR in male fish treated with alachlor, and mixture of endosulfan and molinate in dose response manner. Also, induction of aromatase was detected by RT-PCR in male fish treated with alachlor, endosulfan, and mixture of endosulfan and molinate in sinlilar manner. In this study, swordtail fish exposed to endosulfan or molinate individually did not show any adverse effects. However, Vtg and aromatase expressions and apoptosis were detected in swordtail. fish exposed to the mixture of endosulfan and molinate. These results suggested that low concentrations of mixture of molinate and endosulfan individually do not affect swordtail fish, but may influence genital system, and induce apoptosis.

A study on vulnerability analysis and incident response methodology based on the penetration test of the power plant's main control systems (발전소 주제어시스템 모의해킹을 통한 취약점 분석 및 침해사고 대응기법 연구)

  • Ko, Ho-Jun;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.295-310
    • /
    • 2014
  • DCS (Distributed Control System), the main control system of power plants, is an automated system for enhancing operational efficiency by monitoring, tuning and real-time operation. DCS is becoming more intelligent and open systems as Information technology are evolving. In addition, there are a large amount of investment to enable proactive facility management, maintenance and risk management through the predictive diagnostics. However, new upcoming weaponized malware, such as Stuxnet designed for disrupting industrial control system(ICS), become new threat to the main control system of the power plant. Even though these systems are not connected with any other outside network. The main control systems used in the power plant usually have been used for more than 10 years. Also, this system requires the extremely high availability (rapid recovery and low failure frequency). Therefore, installing updates including security patches is not easy. Even more, in some cases, installing security updates can break the warranty by the vendor's policy. If DCS is exposed a potential vulnerability, serious concerns are to be expected. In this paper, we conduct the penetration test by using NESSUS, a general-purpose vulnerability scanner under the simulated environment configured with the Ovation version 1.5. From this result, we suggest a log analysis method to detect the security infringement and react the incident effectively.

The Assessment Guideline of the Simplified Test Maturity Model (TMM) for An Assessor (심사원을 위한 경량화 테스트 성숙도 모델을 위한 평가 가이드 연구)

  • Jang, Woo Sung;Kim, Ki Du;Son, Hyun Seung;Park, Bo Kyung;Kim, R. Young Chul
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.8
    • /
    • pp.379-384
    • /
    • 2017
  • In real software business environment, there are required to validate software quality in diverse usage range of software for many small & medium companies. Software quality means both qualities of production and process. In our situation, we focus on better process quality of a test organization than a whole organization. But even the original test maturity model (TMM) does not enough to apply with our domestic venture/small & medium companies. To solve this problem, we suggest the simplified test maturity model for our companies. We redefine this simplified model with the original TMM and a test process improvement next (TPI next) model. The previous models just have provided each definition of maturity level, goal and activity per each level, which not exists an assessment guideline and a formal assessing procedure. Due to this reasons, an assessor is difficult to assess the test organization without them. this paper suggest an assessment guideline of the simplified TMM and also define the procedure which is included with activities and byproducts. With these assessment guideline, an assessor can work possible to formally assess test organizations of small & medium companies, and with self assessment guideline they can be correctly provision before assessment of their organizations.

Pattern Analysis of Personalized ECG Signal by Q, R, S Peak Variability (Q, R, S 피크 변화에 따른 개인별 ECG 신호의 패턴 분석)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong;Kim, Joo-Man;Kim, Seon-Jong;Kim, Byoung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.192-200
    • /
    • 2015
  • Several algorithms have been developed to classify arrhythmia which rely on specific ECG(Electrocardiogram) database. Nevertheless personalized difference of ECG signal exist, performance degradation occurs because of carrying out diagnosis by general classification rule. Most methods require accurate detection of P-QRS-T point, higher computational cost and larger processing time. But it is difficult to detect the P and T wave signal because of person's individual difference. Therefore it is necessary to classify the pattern by analyzing personalized ECG signal and extracting minimal feature. Thus, QRS pattern Analysis of personalized ECG Signal by Q, R, S peak variability is presented in this paper. For this purpose, we detected R wave through the preprocessing method and extract eight feature by amplitude and phase variability. Also, we classified nine pattern in realtime through peak and morphology variability. PVC, PAC, Normal, LBBB, RBBB, Paced beat arrhythmia is evaluated by using 43 record of MIT-BIH arrhythmia database. The achieved scores indicate the average of 93.72% in QRS pattern detection classification.

Analysis of the Importance of Subjects to Improve the Educational Curriculum in the Radiological Science - Focused on Radiological Technologists - (방사선(학)과 교육과정 개선을 위한 교과목 중요도 분석 - 방사선사를 중심으로 -)

  • Kim, Jung-Hoon;Ko, Seong-Jin;Kang, Se-Sik;Kim, Dong-Hyun;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.125-132
    • /
    • 2012
  • In this study a group of experts and clinical radiological technologists were surveyed to evaluate the clinical importance of current subjects in the radiological sciences. For the data collection and analysis, an open-ended questionnaire was distributed to the group of experts, and a multiple choice questionnaire was distributed to radiological technologists. Subjects were classified into 9 groups for analysis of the importance of subjects, and in regard to the questionnaire design for measurement of variables, departments and type of hospital were set up as independent variables, and the 9 groups of subjects were set up as dependent variables. As a result, clinical radiological technologists perceived Diagnostic Imaging Technology and practical courses, including general radiography, CT and MRI, as the most clinically necessary subjects, and the group of experts placed most weight on basic courses for the major. The result of this study suggests that the curriculum should be revised in a way that combines theory and practice in order to foster radiological technologists capable of adapting to the rapidly changing healthcare environment.

Development of Traffic Accident Index Considering Driving Behavior of a Data Based (데이터 기반의 도로구간별 운전자의 통행행태를 고려한 교통사고지표 개발)

  • LEE, Soongbong;CHANG, Hyunho;CHEON, Seunghoon;BAEK, Seungkirl;LEE, Young-Ihn
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.4
    • /
    • pp.341-353
    • /
    • 2016
  • Highway is mainly in charge of middle-long distance of vehicular travel. Trip length has shown a growing trend due to increased commute distances by the relocation of public agencies. For this reason, the proportion of driver-driven accidents, caused by their fatigue or sleepiness, are very high on highways. However, existing studies related to accident prediction have mainly considered external factors, such as road conditions, environmental factors and vehicle factors, without driving behavior. In this study, we suggested an accident index (FDR, Fatigued Driving Rate) based on traffic behavior using large-scale Car Navigation path data, and exlpored the relationship between FDR and traffic accidents. As a result, FDR and traffic accidents showed a high correlation. This confirmed the need for a paradigm shift (from facilities to travel behavior) in traffic accident prediction studies. FDR proposed in this study will be utilized in a variety of fields. For example, in providing information to prevent traffic accidents (sleepiness, reckless driving, etc) in advance, utilization of core technologies in highway safety diagnostics, selection of priority location of rest areas and shelter, and selection of attraction methods (rumble strips, grooving) for attention for fatigued sections.

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Ecosystem Diagnosis and Evaluations Using Various Stream Ecosystem Models (다양한 하천생태모델을 이용한 생태계 진단 및 평가)

  • Kim, Ja-Hyun;Lee, Eui-Haeng;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.3
    • /
    • pp.370-378
    • /
    • 2007
  • The objective of this research was to diagnose integrative ecological health in Bansuk Stream, one of the tributaries of Gap Stream, using the fish assemblage during July 2006${\sim}$April 2006. For this research, we selected six sampling sites and applied some approaches such as the Index of Biological Integrity (IBI), Qualitative Habitat Evaluation Index (QHEI), and necropsy-based Health Assessment Index (HAI). The stream health condition, based on the IBI values, averaged 24 (n= 18, range: $10{\sim}46$), indicating "poor${\sim}$fair" condition according to the criteria of US EPA (1993). Physical habitat condition, based on the QHEI, averaged 116 (n=6, range: $77{\sim}139$), indicating "fair${\sim}$good" condition. Values of IBI were more correlated with 3 metrics of instream cover ($M_1$, r=0.553, p=0.017, n=18), flow/velocity ($M_3$, r=0.627, p=0.005, n=18), and riffes/bends ($M_7$, r=0.631, p=0.005, n=18) than other metrics. Value of HAI in the control was zero (i.e., excellent condition), while the values in the T1 and T2 treatments were 5 (range: 0${\sim}$30) and 50 (range: 40${\sim}$80), respectively. The maximum values of IBI (46) were coincided with zero of HAI. Thus, these approaches seem to be a good tool for a diagnosis and evaluations of stream ecosystem health.