• Title/Summary/Keyword: 환경 진단

Search Result 2,100, Processing Time 0.026 seconds

Effects on EDC-like farming chemicals in aquatic Organism (환경생물에 대한 내분비교란물질 의심 농약의 영향)

  • Kim, Hyun-Woo;Park, Kun-Ho;Park, Jin-Hong;Jin, Hua;Kim, Joon-Seong;Eu, Gook-Jong;Cho, Hyun-Sun;Kang, Ga-Mi;Lee, Myung-Sung;Song, Byung-Hoon;Shin, Jin-Sup;Cho, Maing-Haing
    • The Korean Journal of Pesticide Science
    • /
    • v.7 no.3
    • /
    • pp.188-197
    • /
    • 2003
  • Endocrine disrupting chemicals (EDCs) can alter hormone regulation that control reproductive system in animals. The effects of endosulfan, molinate, and alachlor that suspected to have examined disruption EDCs effect on a fish species of interest, Xiphophorus helleri (swordtail fish), were studied using vitellogenin (Vtg) and aromatase as diagnostic biomarkers. Induction of Vtg proteins was detected by RT-PCR in male fish treated with alachlor, and mixture of endosulfan and molinate in dose response manner. Also, induction of aromatase was detected by RT-PCR in male fish treated with alachlor, endosulfan, and mixture of endosulfan and molinate in sinlilar manner. In this study, swordtail fish exposed to endosulfan or molinate individually did not show any adverse effects. However, Vtg and aromatase expressions and apoptosis were detected in swordtail. fish exposed to the mixture of endosulfan and molinate. These results suggested that low concentrations of mixture of molinate and endosulfan individually do not affect swordtail fish, but may influence genital system, and induce apoptosis.

A study on vulnerability analysis and incident response methodology based on the penetration test of the power plant's main control systems (발전소 주제어시스템 모의해킹을 통한 취약점 분석 및 침해사고 대응기법 연구)

  • Ko, Ho-Jun;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.295-310
    • /
    • 2014
  • DCS (Distributed Control System), the main control system of power plants, is an automated system for enhancing operational efficiency by monitoring, tuning and real-time operation. DCS is becoming more intelligent and open systems as Information technology are evolving. In addition, there are a large amount of investment to enable proactive facility management, maintenance and risk management through the predictive diagnostics. However, new upcoming weaponized malware, such as Stuxnet designed for disrupting industrial control system(ICS), become new threat to the main control system of the power plant. Even though these systems are not connected with any other outside network. The main control systems used in the power plant usually have been used for more than 10 years. Also, this system requires the extremely high availability (rapid recovery and low failure frequency). Therefore, installing updates including security patches is not easy. Even more, in some cases, installing security updates can break the warranty by the vendor's policy. If DCS is exposed a potential vulnerability, serious concerns are to be expected. In this paper, we conduct the penetration test by using NESSUS, a general-purpose vulnerability scanner under the simulated environment configured with the Ovation version 1.5. From this result, we suggest a log analysis method to detect the security infringement and react the incident effectively.

The Assessment Guideline of the Simplified Test Maturity Model (TMM) for An Assessor (심사원을 위한 경량화 테스트 성숙도 모델을 위한 평가 가이드 연구)

  • Jang, Woo Sung;Kim, Ki Du;Son, Hyun Seung;Park, Bo Kyung;Kim, R. Young Chul
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.8
    • /
    • pp.379-384
    • /
    • 2017
  • In real software business environment, there are required to validate software quality in diverse usage range of software for many small & medium companies. Software quality means both qualities of production and process. In our situation, we focus on better process quality of a test organization than a whole organization. But even the original test maturity model (TMM) does not enough to apply with our domestic venture/small & medium companies. To solve this problem, we suggest the simplified test maturity model for our companies. We redefine this simplified model with the original TMM and a test process improvement next (TPI next) model. The previous models just have provided each definition of maturity level, goal and activity per each level, which not exists an assessment guideline and a formal assessing procedure. Due to this reasons, an assessor is difficult to assess the test organization without them. this paper suggest an assessment guideline of the simplified TMM and also define the procedure which is included with activities and byproducts. With these assessment guideline, an assessor can work possible to formally assess test organizations of small & medium companies, and with self assessment guideline they can be correctly provision before assessment of their organizations.

Pattern Analysis of Personalized ECG Signal by Q, R, S Peak Variability (Q, R, S 피크 변화에 따른 개인별 ECG 신호의 패턴 분석)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong;Kim, Joo-Man;Kim, Seon-Jong;Kim, Byoung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.192-200
    • /
    • 2015
  • Several algorithms have been developed to classify arrhythmia which rely on specific ECG(Electrocardiogram) database. Nevertheless personalized difference of ECG signal exist, performance degradation occurs because of carrying out diagnosis by general classification rule. Most methods require accurate detection of P-QRS-T point, higher computational cost and larger processing time. But it is difficult to detect the P and T wave signal because of person's individual difference. Therefore it is necessary to classify the pattern by analyzing personalized ECG signal and extracting minimal feature. Thus, QRS pattern Analysis of personalized ECG Signal by Q, R, S peak variability is presented in this paper. For this purpose, we detected R wave through the preprocessing method and extract eight feature by amplitude and phase variability. Also, we classified nine pattern in realtime through peak and morphology variability. PVC, PAC, Normal, LBBB, RBBB, Paced beat arrhythmia is evaluated by using 43 record of MIT-BIH arrhythmia database. The achieved scores indicate the average of 93.72% in QRS pattern detection classification.

Analysis of the Importance of Subjects to Improve the Educational Curriculum in the Radiological Science - Focused on Radiological Technologists - (방사선(학)과 교육과정 개선을 위한 교과목 중요도 분석 - 방사선사를 중심으로 -)

  • Kim, Jung-Hoon;Ko, Seong-Jin;Kang, Se-Sik;Kim, Dong-Hyun;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.125-132
    • /
    • 2012
  • In this study a group of experts and clinical radiological technologists were surveyed to evaluate the clinical importance of current subjects in the radiological sciences. For the data collection and analysis, an open-ended questionnaire was distributed to the group of experts, and a multiple choice questionnaire was distributed to radiological technologists. Subjects were classified into 9 groups for analysis of the importance of subjects, and in regard to the questionnaire design for measurement of variables, departments and type of hospital were set up as independent variables, and the 9 groups of subjects were set up as dependent variables. As a result, clinical radiological technologists perceived Diagnostic Imaging Technology and practical courses, including general radiography, CT and MRI, as the most clinically necessary subjects, and the group of experts placed most weight on basic courses for the major. The result of this study suggests that the curriculum should be revised in a way that combines theory and practice in order to foster radiological technologists capable of adapting to the rapidly changing healthcare environment.

Development of Traffic Accident Index Considering Driving Behavior of a Data Based (데이터 기반의 도로구간별 운전자의 통행행태를 고려한 교통사고지표 개발)

  • LEE, Soongbong;CHANG, Hyunho;CHEON, Seunghoon;BAEK, Seungkirl;LEE, Young-Ihn
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.4
    • /
    • pp.341-353
    • /
    • 2016
  • Highway is mainly in charge of middle-long distance of vehicular travel. Trip length has shown a growing trend due to increased commute distances by the relocation of public agencies. For this reason, the proportion of driver-driven accidents, caused by their fatigue or sleepiness, are very high on highways. However, existing studies related to accident prediction have mainly considered external factors, such as road conditions, environmental factors and vehicle factors, without driving behavior. In this study, we suggested an accident index (FDR, Fatigued Driving Rate) based on traffic behavior using large-scale Car Navigation path data, and exlpored the relationship between FDR and traffic accidents. As a result, FDR and traffic accidents showed a high correlation. This confirmed the need for a paradigm shift (from facilities to travel behavior) in traffic accident prediction studies. FDR proposed in this study will be utilized in a variety of fields. For example, in providing information to prevent traffic accidents (sleepiness, reckless driving, etc) in advance, utilization of core technologies in highway safety diagnostics, selection of priority location of rest areas and shelter, and selection of attraction methods (rumble strips, grooving) for attention for fatigued sections.

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Ecosystem Diagnosis and Evaluations Using Various Stream Ecosystem Models (다양한 하천생태모델을 이용한 생태계 진단 및 평가)

  • Kim, Ja-Hyun;Lee, Eui-Haeng;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.3
    • /
    • pp.370-378
    • /
    • 2007
  • The objective of this research was to diagnose integrative ecological health in Bansuk Stream, one of the tributaries of Gap Stream, using the fish assemblage during July 2006${\sim}$April 2006. For this research, we selected six sampling sites and applied some approaches such as the Index of Biological Integrity (IBI), Qualitative Habitat Evaluation Index (QHEI), and necropsy-based Health Assessment Index (HAI). The stream health condition, based on the IBI values, averaged 24 (n= 18, range: $10{\sim}46$), indicating "poor${\sim}$fair" condition according to the criteria of US EPA (1993). Physical habitat condition, based on the QHEI, averaged 116 (n=6, range: $77{\sim}139$), indicating "fair${\sim}$good" condition. Values of IBI were more correlated with 3 metrics of instream cover ($M_1$, r=0.553, p=0.017, n=18), flow/velocity ($M_3$, r=0.627, p=0.005, n=18), and riffes/bends ($M_7$, r=0.631, p=0.005, n=18) than other metrics. Value of HAI in the control was zero (i.e., excellent condition), while the values in the T1 and T2 treatments were 5 (range: 0${\sim}$30) and 50 (range: 40${\sim}$80), respectively. The maximum values of IBI (46) were coincided with zero of HAI. Thus, these approaches seem to be a good tool for a diagnosis and evaluations of stream ecosystem health.

Power Consumption Analysis of Routing Protocols using Sensor Network Simulator (센서 네트워크 시뮬레이터를 이용한 라우팅 프로토콜의 전력소모량 분석)

  • Kim, Bang-Hyun;Jung, Yong-Doc;Kim, Tea-Kyu;Kim, Jong-Hyun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10a
    • /
    • pp.414-418
    • /
    • 2006
  • 유비쿼터스 컴퓨팅의 인프라가 되는 센서 네트워크는 매우 작은 하드웨어로 이루어지는 많은 수의 센서 노드들로 구성된다. 이 네트워크의 토폴로지와 라우팅 방식은 그 목적에 따라 결정되어야 하며, 하드웨어 및 소프트웨어도 필요한 경우에는 변경되어야 한다. 따라서 그러한 네트워크를 최적으로 설계하기 위해서는 시스템 동작을 확인하고 성능을 예측할 수 있는 센서 네트워크 시뮬레이터가 필요하다. 현존하는 몇몇 센서 네트워크 시뮬레이터들은 특정 하드웨어나 운영체제에 맞추어 개발되었기 때문에, 그러한 특정 시스템들을 위해서만 사용될 수 있다. 그리고 시스템 설계 상의 주요 이슈가 되는 전력 소모량 및 프로그램 실행 시간을 추정하기 위한 어떤 수단도 지원하지 못하고 있다. 이 연구에서는 기존의 센서 네트워크 시뮬레이터들이 갖고 있는 문제점을 해결한 시뮬레이터를 개발하고, 센서 네트워크의 계층적 라우팅 프로토콜인 LEACH, TEEN, APTEEN의 전력소모량을 시뮬레이션을 이용하여 분석하였다. 시뮬레이션의 작업부하인 명령어 트레이스로는 ATmega128L 마이크로컨트롤러용 크로스컴파일러에 의해 생성된 실행 이미지를 사용하였다. 따라서 각각의 라우팅 프로토콜을 실제 센서 보드에서 동작하는 응용 프로그램으로 구현하고, 컴파일된 실행 이미지를 작업부하로 사용하여 시뮬레이션 하였다. 라우팅 프로그램들은 ETRI의 센서 네트워크 운영체제인 Nano-Q+ 1.6.1을 기반으로 구현되었으며, 하드웨어 플랫폼은 옥타컴의 센서 보드인 Nano-24이다. 시뮬레이션 결과에 따르면, 센서 네트워크는 그 사용 목적에 따라 라우팅 프로토콜을 적절히 선택해야 한다는 것을 알 수 있다. 즉, LEACH는 주기적으로 네트워크의 상황을 체크해야 하는 경우에 적합하고, TEEN은 환경의 변화를 수시로 감지해야 하는 경우에 적합하다. 그리고 APTEEN은 전력소모량과 기능 측면을 모두 고려할 때 가장 효과적인 라우팅 프로토콜이라고 할 수 있다.iRNA 상의 의존관계를 분석할 수 있었다.수안보 등 지역에서 나타난다 이러한 이상대 주변에는 대개 온천이 발달되어 있었거나 새로 개발되어 있는 곳이다. 온천에 이용하고 있는 시추공의 자료는 배제하였으나 온천이응으로 직접적으로 영향을 받지 않은 시추공의 자료는 사용하였다 이러한 온천 주변 지역이라 하더라도 실제는 온천의 pumping 으로 인한 대류현상으로 주변 일대의 온도를 올려놓았기 때문에 비교적 높은 지열류량 값을 보인다. 한편 한반도 남동부 일대는 이번 추가된 자료에 의해 새로운 지열류량 분포 변화가 나타났다 강원 북부 오색온천지역 부근에서 높은 지열류량 분포를 보이며 또한 우리나라 대단층 중의 하나인 양산단층과 같은 방향으로 발달한 밀양단층, 모량단층, 동래단층 등 주변부로 NNE-SSW 방향의 지열류량 이상대가 발달한다. 이것으로 볼 때 지열류량은 지질구조와 무관하지 않음을 파악할 수 있다. 특히 이러한 단층대 주변은 지열수의 순환이 깊은 심도까지 가능하므로 이러한 대류현상으로 지표부근까지 높은 지온 전달이 되어 나타나는 것으로 판단된다.의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{99m}Tc$-transierrin이 감염 병소의 영상진단에 사용될 수 있을 것으로 기대된다.리를 정량화 하였다. 특히 선조체에서의 도파민 유리에 의한 수용체 결합능의 감소는 흡연에 의한 혈중 니코틴의 축적 농도와 양의 상관관계를 보였다(rho=0.9, p=0.04). 결론: $[^{11}C]raclopride$ PET을 이용하여 비흡연 정상인에서 흡연에 의한 도파민 유리를 영상화 및 정량화 하였고, 흡연에 의한 선조체내 도파민 유리는 흡연시 흡수된

  • PDF

FMD response cow hooves and temperature detection algorithm using a thermal imaging camera (열화상 카메라를 이용한 구제역 대응 소 발굽 온도 검출 알고리즘 개발)

  • Yu, Chan-Ju;Kim, Jeong-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.292-301
    • /
    • 2016
  • Because damages arising from the occurrence of foot-and-mouth disease (FMD) are very great, it is essential to make a preemptive diagnosis to cope with it in order to minimize those damages. The main symptoms of foot-and-mouth disease are body temperature increase, loss of appetite, formation of blisters in the mouth, on hooves and breasts, etc. in a cow or a bull, among which the body temperature check is the easiest and quickest way to detect the disease. In this paper, an algorithm to detect FMD from the hooves of cattle was developed and implemented for preemptive coping with foot-and-mouth disease, and a hoof check test is conducted after the installation of a high-resolution camera module, a thermo-graphic camera, and a temperature/humidity module in the cattle shed. Through the algorithm and system developed in this study, it is possible to cope with an early-stage situation in which cattle are suspected as suffering from foot-and-mouth disease, creating an optimized growth environment for cattle. In particular, in this study, the system to cope with FMD does not use a portable thermo-graphic camera, but a fixed camera attached to the cattle shed. It does not need additional personnel, has a function to measure the temperature of cattle hooves automatically through an image algorithm, and includes an automated alarm for a smart phone. This system enables the prediction of a possible occurrence of foot-and-mouth disease on a real-time basis, and also enables initial-stage disinfection to be performed to cope with the disease without needing extra personnel.