• Title/Summary/Keyword: 화재 연기

Search Result 767, Processing Time 0.029 seconds

A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors (연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구)

  • Son, Geun­Sik;So, Soo­Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.236-244
    • /
    • 2021
  • Purpose: The purpose of this study is to develop IoT multi-fire detectors combined smoke/carbon monoxide/heat and wireless IoT communication and to confirm the detect performance by smoke generator fire test and cotton wicks fire test. Method: The IoT multi-fire detector combined smoke and CO and combined smoke and heat were experimented the detect performance by smoke generator test and fire test of cotton wicks. And the case of fire alarm was checked. Result: The IoT multi-fire detector combined smoke and CO rung the alarm at the fire test of cotton wicks, did not ring the alarm at the smoke generator test. In comparison, the IoT multi-fire detector combined smoke and heat did not ring the alarm both at the smoke generator test and the fire test of cotton wicks. Conclusion: The IoT multi-fire detector combined smoke and CO detected the only smoke including the carbon monoxide and the IoT multi-fire detector combined smoke and heat did not ring the alarm for lack of heat. As a result, when the developed IoT multi-fire detector was detected the signal more than the set point, the fire alarm was sounded through cotton wicks fire test and smoke generator.

A evaluation study of a fire smoke diffusion delay device installed in a great depth underground double deck tunnel (대심도 복층터널에 설치 가능한 화재연기 확산지연장치 성능 평가 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.225-234
    • /
    • 2018
  • Domestic urban areas are experiencing serious traffic congestion problems due to continuous population growth and increased traffic volume. In order to solve the problem of traffic congestion, the study of great depth underground double deck tunnels using underground space is being actively carried out in the urban areas. The characteristics of great depth underground double deck tunnels are low in cross section, so the spread of fire smoke is expected to spread faster than the road tunnel in case of fire. Therefore, it is necessary to provide a fire smoke delay device which delays the spread of fire smoke when a fire occurs in a tunnels. In the previous study, the diffusion effect was analyzed according to the blocking area when the fire smoke spread delay device was operated through the 3D CFD in the study of preventing the smoke spread in the case of the tunnel fire. A study on fire smoke diffusion delay device using spring elasticity which is excellent in applicability to a tunnel and economical value is studied. In this study, fire smoke spread delay system was developed to fire smoke delay was experimentally analyzed. Fire smoke delay effect of fire smoke delay device appeared. Therefore, it is considered that the can minimize the damage of the victims when installed in the great depth underground double deck tunnels.

A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests (화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, in order to analyze the response characteristics of the smoke detectors which is suitable with the residential fire detector, the paper fire and flammable liquid fire experiment came to be accomplished according to UL Standard for safety for smoke detector for fire alarm signaling systems, UL 268. Also Photoelectric smoke detector, the Analog smoke detector and the single station alarm device came to be used with the specimen and the response characteristics of the smoke detectors which follows in these two types(paper, flammable liquid) test fire came to be analyzed. As a result, according to test fire there was some difference to response characteristics of the smoke detectors.

A study on the fire smoke diffusion delay strategy in a great depth underground double deck tunnel junction (대심도 복층터널 교차로 화재연기 확산지연 방안 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek;Han, Jae-Hee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.115-126
    • /
    • 2019
  • Recently, in order to solve the traffic congestion in urban areas and to improve the peripheral environment, research on the design and construction technology development of great depth underground double-deck tunnel is under way by using the underground space in the urban area. The network type double-deck tunnel is in the form of an intersection with a small cross section and a steep slope as per construction at the base of a flatland, so that the fire smoke spreads rapidly in case of fire, which is expected to cause damage of human life. Therefore, this study is analyzed the delay effect of fire smoke diffusion according to the installation and non - installation of delay system for fire smoke diffusion at the intersection. Fire fumes were delayed up to 270 seconds when the delay system for fire smoke diffusion was installed at the intersection and it is analyzed that the greater the operating area of the delay system for fire smoke diffusion, the more preventable the damage of human life of the intersection.

Establishment of Pre-Pilot Test Bed for Real Scale Experiment Study in Smoke Management (실규모 연기제어 실험연구를 위한 Pre-Pilot Test Bed 구축)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Joo, Sang-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.81-84
    • /
    • 2012
  • 건축물에서 화재가 발생할 경우 연기에 의한 요인이 인명피해의 주요 원인으로 파악되고 있다. 특히 건축물이 고층화, 복합화, 대형화되면서 화재시 연기에 취약한 건축물이 증가하고 있고, 또한 기존의 연기제어 설계기준이 개선되어야 할 필요가 발생하고 있다. 이러한 요구에 부응하기 위해서는 새로운 조건에 대한 연기확산 및 연기제어에 대한 수행되어야 하며, 이론 수치해석적 연구와 더불어 실제적인 실험적 연구가 되어야 한다. 한국건설기술연구원 화재안전연구센터에는 5층규모의 제배연 실험동이 건립되어 있으며, 다양한 건축물 조건 및 연기제어 방식에 따른 실규모의 실험적 연구가 가능하도록 설비가 구성되어 있다. 본 논문에서는 이러한 Pre-Pilot Test Bed의 구축현황과 관련 실험내용을 소개하고자 한다.

  • PDF

CCTV를 이용한 디지털 비디오 연기감지 방식

  • Lee, Sang-Hyeon
    • 방재와보험
    • /
    • s.107
    • /
    • pp.38-44
    • /
    • 2005
  • 기존 화재감지 기술이 점차적으로 발전되어 가고 있지만, 이러한 기존 기술과 다른 자동식 연기감지 방식이 혁신적으로 변화하고 있다. 이런한 혁신기술로 인하여 성장기의 화재를 감지하고 감지기에서 데이터를 분석하고, 화재와 관련된 데이터를 소방관계자에게 전송하는 방법이 계속 변화하고 있다. 기존 화재감지 방식의 예는 여러 가지 감열소자(열감지기), 광전식, 이온화식, 공기흡입형(연기감지기), 자외선.적외선(불꽃감지기)감지 방식이다. 감지기에서 데이터 분석의 형태로 연기농도를 표시하는 방법 등이 있다. 화재조건을 전송하는 방법은 특정한 구성요소(발신기, 감지기 등)의 위치(어드레스), LCD, CRT 그래픽 표시장치에서 많은 발전이 있었다. 이러한 혁신 기술은 화재경보 설비 판매시장, 설치방법, 기술기준의 변화에 많은 영향을 미치고 있다. 최근 개발된 디지털 비디오 연기감지 방식은 자동화재 감지 방식에 있어서 새롭고 급진적인 변화를 요구하고 있다.

  • PDF

Uncertainty Analysis of the Optical Smoke Density Measurement through the Doorway in a Compartment Fire (구획화재의 출입구를 통한 광학적 연기밀도 측정의 불확실성 해석)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-79
    • /
    • 2013
  • The present study measured the light transmission to quantify the smoke density(smoke mass concentration) through the doorway in a compartment fire and performed the uncertainty analysis to evaluate the reliability of the measurement technique. The optical light extinction method based on Bourguer's law was applied to estimate the smoke density of doorway exhausting smoke flow in upper layer of a compartment for methane gas fires. The measurement uncertainty of the light extinction measurement was evaluated for the light transmittance, path length, and specific mass extinction coefficient and the expanded uncertainty was estimated about 20% with confidence level of 95%. The mean smoke density through the doorway for the methane fire was calculated for quasi-steady fire and the smoke density linearly increased as the GER increased.

A Study on the Performance Improvement of Smoke Control with Smart Dampers (스마트 댐퍼를 적용한 제연 성능 개선에 관한 연구)

  • Choi, Hyun-Jun
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.159-160
    • /
    • 2023
  • 화재가 발생할 때 연기로부터 안전하게 피난과 소방관의 소화활동을 위해 제연설비가 설치되어 있다. 기존의 자동차압·과압 조절형 급기댐퍼는 화재층과 비화재층을 구분하지 못하므로 화재가 발생하지 않는 층에서 피난을 할 경우 화재층이 연기로부터 보호받지 못한다. 스마트 댐퍼를 적용하면 화재층과 비화재층을 구분하므로 화재층을 연기로부터 보호가 가능하다.

  • PDF

A Study of Smoke Spread and Flow in a Long Corridor (복도에서의 연기 확산 및 유동에 관한 연구)

  • 김충익;유홍선;김명배;한용식;김진곤;윤명오;김상욱
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.29-39
    • /
    • 1998
  • 복도는 사무실용 건물, 호텔 등 공중이용 건물에서 중요한 피난경로의 일부이다. 화재로 복도에 연기가 확산되면 그 온도, 연층의 높이, 유해물질의 농도 등에 따라 피난에 심각한 장애를 가져올 수 있다. 본 연구는 이러한 복도에서의 연기의 확산 및 유동에 관하여 연구하기 위하여 길이 40m의 복도에서 pool fire로부터의 연기 유동에 관한 실제크기의 실험과 수치해석을 수행하였다. 화재실과 그에 접해있는 긴 복도가 있는 실험장치에 직경 15, 20, 30cm의 가솔린 pool을 화재실 중앙에서 점화 시켰다. 연기의 온도 및 이동을 측정하기 위해 전장 중앙선을 따라 열전대를 설치하였고 연층의 두께를 측정하기 위하여 수직방향으로 세곳에 열전대가 부착된 수직봉을 설치하였다. 아르곤 레이저 sheet 과 비디오 카메라를 이용해 연기의 유동을 가시화 하였다.

  • PDF

Developements of Recognition Fire Levels based on Fuzzy Inference System (퍼지인지시스템을 통한 화재상황인식 모델개발)

  • Jin, Hyun-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.393-395
    • /
    • 2011
  • 기존의 화재 감시 시스템은 보통 연기, CO 혹은 온도와 온도의 변화량을 가지고 화재 여부를 판단하였다. 대부분의 각각의 센서에서 측정된 값을 가지고 미리 설정한 값과 비교하여 기준을 넘었을 경우에 화재라고 결정한다.건물 내부에 화재가 발생하였을 경우에는 연기와 고열로 인하여 접근이 어려울 경우가 대부분이다. 사람의 손이 닿지 않는 경우에 화재 감시반 센서모듈을 통하여 고열과 가득한 연기로 인한 내부 환경을 판정하여서 화재상황을 인식하는 방식을 제안한다.

  • PDF