Abstract
Recently, in order to solve the traffic congestion in urban areas and to improve the peripheral environment, research on the design and construction technology development of great depth underground double-deck tunnel is under way by using the underground space in the urban area. The network type double-deck tunnel is in the form of an intersection with a small cross section and a steep slope as per construction at the base of a flatland, so that the fire smoke spreads rapidly in case of fire, which is expected to cause damage of human life. Therefore, this study is analyzed the delay effect of fire smoke diffusion according to the installation and non - installation of delay system for fire smoke diffusion at the intersection. Fire fumes were delayed up to 270 seconds when the delay system for fire smoke diffusion was installed at the intersection and it is analyzed that the greater the operating area of the delay system for fire smoke diffusion, the more preventable the damage of human life of the intersection.
Keywords
Great depth underground double-deck tunnel; Delay system for fire smoke diffusion; Smoke; Fire; Junction;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Choi, J.H. (2016), "Construction of urban underground road: attractive alternative for reducing traffic congestion", The Magazine of the Korean Society of Civil Engineers, Vol. 64, No. 8, pp. 34-37.
2 Kim, H.G., Lee C.W. (2004), "A study on the relationship among traffic accidents, fire occurrences and tunnel characteristics in local road tunnels", Journal of Korean Tunnelling and Underground Space Association, Vol. 6, No. 3, pp. 199-212.
3 Ministry of Land, Infrastructure and Transport (2011), Road design manual, Sejong, Korea.
4 Ministry of Land, Infrastructure and Transport (2012), Land transport and maritime R&D report: appendix-1, Sejong, Korea, pp. 140.
5 Ministry of Land, Infrastructure and Transport (2016), Guidelines for installing and managing road tunnel disaster prevention facilities, Sejong, Korea.
6 Shin, T.G., Moon, J.J., Yang, Y.W., Lee, Y.T. (2018), "A evaluation study of a fire smoke diffusion delay device installed in a great depth underground double deck tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 20, No. 1, pp. 225-234.   DOI
7 Yang, Y.W., Moon, J.J., Shin, T.G. (2016), "A research for preventing smoke diffusion in case of fire in great depth underground double-deck tunnel", Journal of The Korean Society of Mineral and Energy Resources Engineers, Vol. 53, No. 2, pp. 158-163.   DOI
8 Yang, Y.W., Moon, J.J., Shin, T.G. (2017), "A research and development for the delay device against fire smoke diffusion in great depth underground double deck tunnels", Journal of The Korean Society of Mineral and Energy Resources Engineers, Vol. 54, No. 2, pp. 110-116.   DOI
9 Yoo, J.O., Oh, B.C., Kim, H.G. (2013), "A numerical study on the characteristics of the smoke movement and the effects of structure in road tunnel fire", Journal of Korean Tunnelling and Underground Space Association, Vol. 15, No. 3, pp. 289-300.   DOI