• Title/Summary/Keyword: 화재 사고

Search Result 1,170, Processing Time 0.026 seconds

The Arc Dispersion Properties by Switching of High Sensitivity Type RCD Contacts (고감도형 누전차단기 접점의 스위칭에 따른 아크 비산 특성)

  • Choi Chung-Seog;Kim Dong-Woo;Kim Young-Seok;Lee Ki-Yeon
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.63-68
    • /
    • 2005
  • In this study, the arc dispersion properties were analyzed according to switching of high sensitive type Residual Current Protective Device(RCD) contacts. Arc dispersion and ignition process was taken by high speed imaging system(HSIS). In this experiment, electric lamps(60 W) and heaters(950 W) were connected in parallel as loads. In case of normal RCD, it took about 2.3(ms) from the generation of arc to the extinction of uc. When arc was dispersed in normal RCD, it did not ignite cotton. Whereas, in case of RCD deteriorated by NaCl solution, the range of arc dispersion was wider and the arc lasted for 3.3[ms] more compared to normal RCD. And the arc ignited cotton. In order to prevent accidents caused by RCD, we should be careful of environmental factors, such as dust and humidity, and the parts of RCD should be used as incombustible materials.

Analysis of the Wireless Communication Environment in the Narrowed Residential Space for the Fire fighting Operation (소방작전을 위한 협소거주 공간의 무선 통신 환경 분석)

  • Park, Hyun-Ju;Hong, Sang-Beom;Choi, Hyuk-Jo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.242-248
    • /
    • 2017
  • Recently, Population has been concentrated in cities due to rapid economic growth. As a result, urban buildings are becoming more dense, high-rise, and diversified. The shape of these urban buildings increases the risk of fire, accidents and crime. The narrow living space has the characteristic of the unchanged floor. In case of a fire, the living space of the narrow residence is large in the damage because the smoke diffusion rate is fast. The radio wave transmittance and transmission distance of wireless communication used in fire fighting operations vary depending on the type of building materials and buildings. Therefore, this paper analyzes the building materials and structural characteristics of the narrow residential space for efficient fire fighting operations. We have developed a communication environment solution for a narrow residential space for the optimal fire fighting operation through the measurement of the radio wave transmittance and the transmission distance of the wireless communication.

The Study for the Optimal Location of Fire Stations in Seoul (서울시의 소방서 최적입지에 관한 연구)

  • Kim, Geun-Young;Kang, Sung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.153-159
    • /
    • 2002
  • Disasters are the phenomena that we have to prevent the occurrence in order to keep the safety to human lives and properties, and if occurred, we have to minimize the economic, social, and mental costs of the occurred disasters or incidents. This research analyzes the optimal location of fire stations in terms of served population maximization in Seoul. This research introduces "the maximal covering location problem(MCLP)," one of the optimization techniques, as the primary research method. This research also applies a geographic information system into spatial distribution analyses of existing fire stations and observed fire incidents. Results from the analyses show that the existing location of fire stations and branches need to be improved. The dispatch location of fire engines should be reconsidered for rapid services of fire fighting.

Convergence Technique Study through Simulation Thermal Analysis due to the Shape of Electric Heater (전기 히터의 형상에 따른 시뮬레이션 열 해석 연구를 통한 융합 기술 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.241-246
    • /
    • 2015
  • In cold winter season, the apparatuses of heating and heater which warm up the interior of a room are necessary element and the used amount of these apparatuses from the year 2000 has been increased abruptly. But, the fire accident and the danger of fire are also increased. Therefore, 3D modelling is done by referring three kinds of the electric heaters as the heaters of ceramic, carbon and near infrared ray sold in the city for the design of more safe heating apparatuses in this study. The thermal analyses with these models are carried out and the durabilities due to the thermal deformation and stress are studied. By the background of the study results derived in this study ultimately, the durabilities of electric heater models due to each shape can be anticipated and contributed to the development of new heating apparatus with more safe resistance to fire. And it is possible to be grafted onto the convergence technique at design and show the esthetic sense.

How Phenolic Composites were chosen - In Case of England (6) (페놀 컴포지트 실용화의 길 - 영국의 경우 (CASE STUDY 6))

  • Nomaguchi, Kanemasa;Forsdyke, Ken L
    • Composites Research
    • /
    • v.17 no.6
    • /
    • pp.58-66
    • /
    • 2004
  • As the first modem industrialized country in the world, so England UK was safetyfied from "SMOKE FIRE DANCER" at London Underground as the first country also. Indeed, the quick decision maker of Grate London Metropolitan must be serious, while the technology developing people also so eager in rebuilding safer composite system for public security accumulating basic data at their laboratories. Mr. Ken L. Forsdyke, one of co-authors of this paper, who was the project leader at BP Chemicals International Company at that time, is now telling you some key points adding to the stories he mentioned before in this series, "How Phenolic Composites were chosen". Now, with another article of the basic data, our tales of "In Case England" will be closed. May God save people from "Horror SMOKE FIRE".ople from "Horror SMOKE FIRE".IRE&".ot;.

Detection Technique and Device of Series Arcing Phenomena (직렬아크현상의 검출기술 및 장치)

  • Ji, Hong-Keun;Jung, Kwang-Suk;Park, Dae-Won;Kil, Gyung-Suk;Seo, Dong-Hoan;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.332-338
    • /
    • 2010
  • Annually, electrical fires caused by arcing phenomena in power system rapidly increase as the use of more electric appliances, but there is no established method for the prevention of the accidents. With this background, this paper dealt with the experimental results on a series arc detection technique and a device for air conditioners. Series arcing phenomena that is generated in incomplete connection of air conditioners was simulated, and the frequency spectrum was analyzed. The Fast Fourier Transform (FFT) of the arc pulse showed that the dominant frequency components exist in ranges of 190 kHz~250 kHz and 900 kHz~1.6 MHz. An arc detection circuit with low cut off frequency of 170 kHz to attenuate 60 Hz by 170 dB and a signal discriminator were designed. Also, an algorithm which separate series arc signal from unwanted noises produced by switching operation, inverter, and surge was proposed. Application experiment was carried out on several types of air-conditioners by using the arc generator specified in UL1699, and the results showed the over 99 % accuracy.

The cause analysis of explosion on junction termination of 345kV cable (345 kV 케이블 종단접속부에서의 폭발사고 원인분석)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok;Choi, Myeong-Il
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.12a
    • /
    • pp.63-79
    • /
    • 2010
  • It is found to the arc trace on the junction termination of 345kV cable. According to the analysis of the cable material is judged to be good. Manufacturing and design problems are not considered. In construction defects, it was estimated to the low level of insulation oil. In the majority of the arc trace appeared XLPE is found. However, there is no Soots mark, yellow band has not been confirmed, not associated with a radial arc of the spider leg is not evidence. In other opinions, void, contamination or jut are not found on the inside of XLPE. Thus, by the attachment of the impurities in surface of XLPE insulation is judged to the breakdown.

  • PDF

5G service and universal service (5G시대 통신서비스의 공익성 제고 방안에 대한 모색)

  • Kim, Sung-Wook
    • Journal of Digital Convergence
    • /
    • v.18 no.2
    • /
    • pp.103-110
    • /
    • 2020
  • The fire incident of KT's Ahyun branch occurred last year indicates that hyper-connected society led by 5G technology would be a dystopia instead of a utopia unless seamless connection of 5G service is well secured. Looking backward on 1999, we could peacefully and happily greet the new millennium by making a great effort to prevent the millennium bugs(Y2K) from causing the catastrophe such as a shut-down of banking system. Likewise, we should make a great effort to keep 5G networks and 5G service continuously working without the disruption of even just a second, which would enable us to avoid facing any catastrophes caused by the disruption of 5G service. As a way to do so, it can be considered that 5G service is designated as universal service because it has the key features of public goods like telephone and high-speed internet services.

The study of quantitative analysis for noxious gases of plastic materials by remote sensing open path FT-IR spectrometer (원격 측정용 개방 경로형 FT-IR spectrometer를 사용하여 플라스틱 재료의 유해 가스 정량 분석에 관한 연구)

  • Cho, Nam-Wook;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.230-235
    • /
    • 2012
  • It is to use many plastic materials as living essential goods. But when the fire is happened, owing to noxious gases, many men should be injured. Therefore as the noxious gases are measured by open path FT-IR spectrometer as remote monitoring, the demage of men could be minimized. Such this system consists of a Fourier transform spectrometer and infrared lamp fitted to long length. The study was to do the quantitative analysis on CO, $NO_2$, HCl, HF gas by remote monitoring open path FT-IR spectrometer. And the method of it should use MLR (multiple linearity regression) method. As result, It was confirmed to be more than 0.95 as $R^2$ of MLR. And then Urethane and PVC of plastic materials selected was burned, the concentration of polluted gases were measured by remote monitoring method.

A Study on the Analysis of Damage Cause for MOF Installed in 22.9 kV Power Receiving System (22.9 kV 수전설비 시스템에 설치된 계기용변성기의 소손원인 판정에 관한 연구)

  • Kim Hyang-Kon;Shong Kil-Mok;Kim Dong-Ook;Choi Chung-Seog
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.93-98
    • /
    • 2005
  • The purpose of this paper is to judge the damage cause of instrument transformer(MOF; Metering Out Fit) installed in 22.9kV power receiving system. In the three-dimensional analysis of the restored MOF, the damage pattern progressed from inside to outside, there was no damaged part in the upside. The resistance of the carbonized middle part is roughly $100\kappa\Omega$ and the exothermic temperature at inside is presumed as about $300\~800^{\circ}C$ in the result of metallurgical structure analysis. The structure and the composition rate on metal surface by SEM is similar. In the result of FT-IR analysis, we can observe the absorbtion peak at $1500cm^{-1}\;and\;1730 cm^{-1}$ is small. The high exothermic peak showed at the center part of the coil in the result of DTA.