• Title/Summary/Keyword: 화재 방재

Search Result 3,990, Processing Time 0.025 seconds

Study of IoT Service Strategy for Prevent Disasters (재난재해 감소를 위한 사물인터넷 서비스)

  • Yoon, YoungDoo;Choi, Hun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.102-109
    • /
    • 2017
  • The Nation's Constitution stipulates that the nation should strive to prevent disasters and protect the public from harm. That is, the nation is a protector of the protection of people's lives and property from potential danger. The disasters are the most important global issues, and disasters scope are not confined to natural disasters such as pre-existing earthquakes, landslides, floods, fires and fires extend to cyber terror and disease. In the age of IoT and ability of analyze big data, the establishment of a disaster prevention service system in modern society is a priority for the nation. In this study, we will explore the disaster prevention services for each country using IoT technology. Based on the research, it is believed that it will be the foundation for establishing strategies for service system of disasters using IoT technology.

A Study on the Microstructure Properties of $SnO_2$ Gas Sensors Fabricated by Sol-Gel Method (졸-겔법으로 제작된 $SnO_2$ 가스센서의 미세구조 특성에 관한 연구)

  • Jang, K.U.;Kim, M.H.;Lee, W.J.;Lee, H.S.;Kim, T.W.;Chung, D.H.;Ahn, J.H.;Lee, S.I.;Kim, S.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.102-105
    • /
    • 2005
  • 가스센서는 응용 분야와 기능 및 종류가 다양하고 최첨단 분야로서 학문적으로는 물리, 화학, 전기, 전자 및 기계 등의 배경을 필요로 하며 산업적으로는 공업 전 분야와 농림, 축산, 사무기기에서 뿐만 아니라 공해 방진용(자동차 연소제어 및 배출가스 제어, 대기오염 감시등), 민생용(조리, 환기, 공조 등), 교통 보안용(음주운전측정 및 음주운전 방지장치 등), 방재용(가스 누설 탐지기, 불완전 연소 방지, 산소 결핍, 화재 등), 의료용(호기, 마취가스의 분석 등) 매우 광범위하며 점점 더 확대되어 가고 있다. 본 연구에서는 검출 가스 종류에 따라 졸-겔법으로 감응막을 최적 설계하고, 최적으로 설계된 감응막을 디핑법으로 코팅처리한 후 최적으로 열처리하여 센서를 제작하였다. 또한, 자체 제작한 가스검출 시스템에 제작된 센서를 장착하여 센서의 가스 검출 특성을 측정하고, 측정 데이터를 이용하여 휴대용 가스 검출 시스템을 설계 제작하였다.

  • PDF

A study on the annoyance and disturbance of floor impact noise according to noise sensitivity based on questionnaire survey (설문조사를 통한 소음 민감도에 따른 층간소음에 의한 성가심과 생활방해 연구)

  • Jeong, Jeongho;Lee, Sungchan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.428-436
    • /
    • 2018
  • The response to noise may differ depending on the respondent's noise sensitivity. In this study, it was investigated that the noise sensitivity, the annoyance and disturbance of floor impact noise and opinions on their neighbors. The questionnaire respondents were divided into two or three groups based on noise sensitivity, and annoyance and disturbance on floor impact sound were compared. The noise sensitivity questionnaire method was presented. The questionnaire survey was conducted on 233 residents of Seoul, Gyeonggi - do area. As a result of the questionnaire survey, when the sensitivity group was divided into three groups, it was found that there was a significant difference between the groups with the noise sensitivity and the disturbance reaction. As a result of the opinions on their neighbors, positive responses to neighbors increased with age. Also, it was found that there was a low perception of inter - floor noise and life disturbance of the group having positive feelings about neighbors.

Study on the effective response method to reduce fire risk of wood fuel heating system (화목 연료 난방설비의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Bong-Woo;Lee, Guen-Cull;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.163-171
    • /
    • 2019
  • Recently, rural housing in urban areas has been increasing due to the improvement of income level. With the increase of the construction of the power house, the installation of the heating system using the harmonious fuel for the purpose of heating and the beauty of the room is increasing rapidly. In addition to the increasing use of firewood heating equipment, the incidence of fire is also increasing. Analysis of the National Fire Data System of the Fire Department The result of the analysis of the National Fire Data System Many parts of the fire are incinerated by the accumulation of tar due to the incompleteness of periodic cleaning inside the cylinder. The distance between the fire extinguisher and the combustible materials such as ceiling, Resulting in fire. In addition, it was found that much of the fire of the firewood heating system in the time zone occurs during the sleeping and resting time and there is not enough time for the residents to cope. This, in turn, causes serious harm to the lives and property of the users of the pyrotechnic heating system. Therefore, in this study, domestic and foreign standards and laws related to fuel oil heating facilities were analyzed and 12 cases of fire accidents were analyzed. Through the revision of the fire prevention and firefighting facilities installation and maintenance law, the installation standards of the alarm and fire extinguishing facilities were presented.

Study on Solidification and Strength of Soft Soils by Using Waste Magnesia-Carbon Powder (폐 Magnesia-Carbon Powder를 이용한 연약지반 고형화 및 강도 증진에 대한연구)

  • Choi, Hun;Song, Myong Shin;Kang, Hyung Ju;Jung, Eui Dam;Kim, Ju Seng
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • Magnesia-carbon brick is used to refractory material in Converter and/or Ladle furnace for molten steel manufacturing. The rapid growth of steel making industry, molten steel industry is increased. Therefore, growth of molten steel industry lead to make waste magnesia-carbon brick by repair of Converter and/or Ladle furnace. These waste magnesia-carbon brick is abandoned all. Besides, as it is loosely composed of silt and clay including sand falling according to the type of gangue, rainwater inflows and outflows relatively easily, but silt or clay particles absorb water for a long period, weakening ground. This study tried to show that when colluvial soil is solidified using waste magnesia-carbon brick powder as a way to solidify strengthen the rigidity of colluvial soil.

A survey on noise generation and conversation interruption in cafes (카페 공간의 소음과 대화 방해에 대한 설문조사)

  • Jeong, Jeong-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.660-670
    • /
    • 2021
  • As various people use the cafe for various purposes, it is difficult to hear conversations with the accompanying people due to the noise and background music of people around the respondents. In addition, there is a need for improvement related to the noise and sound inside the cafe, such as making it easier to hear the conversations of nearby users. 212 adult men and women participated in the questionnaire on the survey on cafe acoustics and noise conditions. As a result of the survey, about two-thirds of the respondents said that they did not prefer noisy cafes, and that the noise of cafes had a negative effect. The major source of noise in cafes is the sound of people around users, and more than 40 % of the respondents said that they could not hear well the sound of conversations with their accompanying people due to the sounds of those around them, or that they were concerned about their own conversations being transmitted to those around them. As a result of the survey on cafe sound and noise, it was found that improvements were needed to secure the voice privacy of cafe users as well as the voice intelligibility.

An Experiment Study on Electric Vehicle Fire and Fire Response Procedures (전기차 화재 실험 및 대응방안에 관한 연구)

  • Ki-Hun Nam;Jun-Sik Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.63-70
    • /
    • 2024
  • Lithium-ion batteries (LIB) are widely used in various sectors, such as transportation (e.g., electric vehicles (EV)) and energy (e.g., energy storage facilities) due to their high energy density, broad operating temperature (-20 ℃ ~ 60 ℃), and high capacities. LIBs are powerful but fragile on external factors, including pressure, physical damage, overheating, and overcharging, that cause thermal runaway causing fires and explosions. During a LIB fire, a large amount of oxygen is generated from the decomposition of ionogenic materials. A water fire extinguisher that helps with cooling and suffocating must be essentially required at the same time. In fact, however, it is difficult to suppress LIB fires in the case of EVs because a LIB is installed with a battery pack housing that interrupts direct extinguishing by water. Thus, this study aims to investigate effective fire extinguishing measurements for LIB fires by using an EV. Relevant documents, including research articles and reports, were reviewed to identify effective ways of LIBs fire extinguishing. A real-scale fire experiment generating thermal runaway was carried out to figure out the combustion characteristics of EVs. This study revealed that the most effective fire extinguishing measurements for LIB fires are applying fire blankets and water tanks. However, there is still a lack of adequate regulation and guidelines for LIB fire extinguishment. Taking this into account, developing functional fire extinguishment measurements and available regulatory instruments is an urgent issue to secure the safety of firefighters and citizens.

Comparison of Response Systems and Education Courses against HNS Spill Incidents between Land and Sea in Korea (국내 HNS 사고 대응체계 및 교육과정에 관한 육상과 해상의 비교)

  • Kim, Kwang-Soo;Gang, Jin Hee;Lee, Moonjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2015
  • As the type of Hazardous and Noxious Substances(HNS) becomes various and the transport volume of HNS increases, HNS spill incidents occur frequently on land and the sea. In view of various damages to human lives and properties by HNS spills, it is necessary to educate and train professional personnel in preparation for and response to potential HNS spills. This study shows the current state of response systems and education courses against HNS spill incidents on land and the sea to compare those with each other between land and sea in Korea. Incident command system on land are basically similar to that at sea, but leading authority which is responsible for combating HNS spills at sea is changeable depending on the location of HNS spill, as it were, Korea Coast Guard(KCG) is responsible for urgent response to HNS spill at sea, while municipalities are responsible for the response to HNS drifted ashore. Education courses for HNS responders on land are established at National Fire Service Academy(NFSA), National Institute of Chemical Safety(NICS), etc., and are diverse. Education and training courses for HNS responder at sea are established at Korea Coast Guard Academy(KCGA) and Marine Environment Research & Training Institute(MERTI), and are comparatively simple. Education courses for dangerous cargo handlers who work in port where land is linked to the sea are established at Korea Maritime Dangerous Goods Inspection & Research Institute(KOMDI), Korea Port Training Institute(KPTI) and Korea Institute of Maritime and Fisheries Technology(KIMFT). Through the comparison of education courses for HNS responders between land and sea, some recommendations such as extension of education targets, division of an existing integrated HNS course into two courses composed of operational level and manager level with respective refresh course, on-line cyber course and joint inter-educational institute course in cooperation with other relevant institutes are proposed for the improvement in education courses of KCG and KOEM(Korea Marine Environment Management Corporation) to educate and train professionals for combating HNS spills at sea in Korea.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

A Study on Flame Retardant Performance of Vertical Blind and Roll Screen (버티칼 브라인드와 롤 스크린의 방염성능 유지에 관한 연구)

  • Jeong, Hyun Gyu;Cho, Woncheol;Lee, Tae Sik
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.41-46
    • /
    • 2010
  • This study focuses on two points. First, I have examined the difference on combustion between flame-retardant and non flame-retardant products including vertical blinds and roll screens that are widely used as a substitute for fabric curtains. The second point is to see how long flame-retardant goods can be durable, that is, flame retardant durability after washing in liquid. the experiment on the flame-retardant ability before and after washing of vertical blinds and roll screens that have been used for a long time in fire protection construct. Comparing and analyzing domestic and foreign laws on flame-retardant after the experiment on durability of these products. I aim to draw necessity for increased application of internal laws and regulations on flame-retardant and show how to improve the point at issue. According to the result, clear differences in performance and safety were observed between flame-retardant and non flame-retardant products. flame-retardant materials can prevent things from fire spread without igniting but melting when they've met flame and burnt, In contrast, non flame-retardant material for experiment which size is 120cm long takes less than 3 minutes only to be completely destroyed by fire. However, it was expected for flame-retardant durability of flame-retardant blinds which are not washable to decrease flame-retardant durability after being washed with water, there was no sharp difference. so it is demonstrated that flame-retardant blinds can keep flame-retardant durability. accordingly through the strict course of product we are concerned about keeping durability.

  • PDF