• Title/Summary/Keyword: 화재조사

Search Result 1,212, Processing Time 0.02 seconds

Perceptions about the Professional Ethics of EMT (응급구조사 직업윤리에 대한 인식조사)

  • Yun, Hyeong-Wan;Lee, Jae-Min
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.71-78
    • /
    • 2014
  • Complex ethical issues of Emergency Medical Techinician (EMT) out-of hospital emergency medical scene and the ER (Emergency Room) behaviors were studied. The survey was conducted by 500 EMT group members working in the field of ambulance work and general hospital and it was about their work ethics, discussions and solutions about the transferred patients, and ethics regarding Do Not Attempt Resuscitate (DNAR). The survey includes work ethics, awareness about the target job, a discussion on the transfer of patients, measures, and deathbed. Discussions about the patient's condition and diagnosis results were majorly absent during patient transportation at the emergency care scene. More than 90% of emergency care transfer were inappropriate. Sometimes, EMT working in the field facing morally unethical problems beyond their responsibility. When EMT, who can not make death diagnosis, received deathbed related DNAR issues, they gone through severe ethical conflicts. The institutional support and therapy for EMT was weak. In Korea, especially in the accident site, ethical issues education is more needed than DNAR prevalence of education and guidance. If ethics training and guidance are given to EMT, a lot of moral errors in the field can be resolved.

Effect of All-out Condition on Physical Balance, Agility and Power (최대 지친상태가 신체의 평형성, 민첩성, 순발력에 미치는 영향)

  • Huh, Man-Dong;Bang, Chang-Hoon
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.120-125
    • /
    • 2010
  • The aim of study intends to investigate effect of All-out condition on physical balance, agility and power and to provide the base data for the safety of firefighter. The results of the study are as follows. For power estimation, the sargent jump is $41.0{\pm}3.2cm$ before estimation and $42.2{\pm}6.02cm$ after estimation as All-out condition. For static balance estimation, the closed-eyes foot balance is $40.3{\pm}36.8$sec before estimation and $27.5{\pm}27.18$sec after estimation. For dynamic balance estimation, the beam walking is $6.2{\pm}1.22$sec before estimation and $6.4{\pm}1.57$sec after estimation. The results are statistically significant. For agility estimation, the side step is $40.3{\pm}3.40$rep/20sec before estimation and $43.3{\pm}2.50$rep/20sec after estimation. The results are statistically significant. The wholebody reaction time is $0.21{\pm}0.05$sec before estimation and $0.18{\pm}0.02$sec after estimation.

Study on the Improvement of a Special Fire Police Judicial Police System (소방특별사법경찰제도의 문제점에 따른 개선방안 연구)

  • Park, Hyeong-Jin;Kim, Jung-Rae;Kim, Jong-Buk;Cha, jin;Kwon, Hyun-Seok;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.77-86
    • /
    • 2018
  • In recent years, the high growth of the Korean society has led to the development of large and small incidents and accidents, while safety regulations, such as the firefighting sector, have been strengthened with the expectation of people desiring safety. This study surveyed the problems and improvement plan of the current operation centered on the fire service public officers in Gyeonggi-do and Gangwon. As a result of the main research, it is necessary to arrange and carry out excellent investigative manpower, such as lawyers and professional career veterans in the fire department, metropolitan city and provincial firefighting headquarters, and frontline fire departments. In particular, it was suggested that a special task force should be established and set up in the above agency, and the planning investigation and enforcement work should be solved through subdivision of the fire special enforcement officer tasks, and the judicial cases that are difficult to be handled by the local fire station. In future research, it will be necessary to study the field of fire - fighting specialists' needs for more specialized education and various disaster field experiences.

Evaluation of Combustion gas during Fire Tests of Veneers Coated with Ammonium Salts (암모늄염으로 도포시킨 베니어판의 연소 시에 발생하는 연소가스 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.93-99
    • /
    • 2016
  • This study tested the combustion characteristics of veneer specimens coated with four kinds of ammonium salts. Each veneer specimen was coated three times with 20 wt.% ammonium salt solutions at room temperature. After drying, the combustion characteristics of the specimens coated with chemicals, were investigated using the cone calorimeter (ISO 5660-1, 2). The specimens coated with monoammonium phosphate (MAPP) and, diammonium phosphate (DMPP) showed a 6.7% and, 10.0%, lower mean heat release rate ($HRR_{mean}$), respectively, than that of the uncoated specimen. On the other hand, the specimens coated with MAPP showed a 15.7% higher $CO_{peak}$ production rate and the specimens coated with DAPP showed by 8.2% lower rate than that of the uncoated specimen. The veneer coated with ammonium sulfate (AMSF) and DAPP showed a 9.6% and 33.3% lower the peak smoke production rate ($SPR_{peak}$) than that of the uncoated specimen. In addition, the time to the peak smoke extinction area ($SEA_{peak}$) was delayed by 38.4% in the specimens coated with DAPP than the uncoated specimen. Therefore, DAPP inhibited the combustion properties of the veneer and showed a tendency to reduce smoke production.

A Study on the Safety Management Differences According to Social Welfare Facility Type (사회복지시설의 유형에 따른 안전관리의 차이에 관한 연구)

  • Shin, Hyo-Jin;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.89-97
    • /
    • 2014
  • At a time of growing importance of safety management in the social welfare facility by the increase of social welfare facilities, this study analysed safety perceptions about facility management, facility conditions, and facility structure and arrangement. This study sample consisted of 204 service providers and service users in 12 social welfare facilities. T-test and ANOVA were used to find the group differences among facility types. The findings were as follows. Firstly, safety perceptions of the service providers were significantly higher than those of service users in terms of facility management, and facility structure and arrangement. Secondly, in terms of facility types, the respondents in the family service center had lower safety perceptions than the respondents in other service in all three areas. Thirdly, facilities that are of 10 years or older had higher safety perceptions than the respondents of facilities that are 6 to 10 years old in the area of facility management, and facility structure and arrangement. Fourthly, in regard to building heights, the respondents in 3 to 4 story facilities had statistically higher safety perceptions than respondents in 1 story facilities. Finally, looking at the relationship between floor area and safety perceptions, safety perceptions of the respondents of less than $400m^2$ facilities or $600m^2$ and more facilities were significantly higher than those of $400m^2{\sim}$ less than $600m^2$ facilities.

Design and Verification of Housing and Memory Board for Downsizing for Crash Protected Memory Module (충돌보호메모리모듈의 소형화를 위한 하우징 및 메모리 보드 설계와 검증)

  • Kim, Jun-Hyoung;Kim, Jung-Pil;Kim, Jeong-Yeol;Kim, Tae-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.81-88
    • /
    • 2020
  • Flight data recorder is a equipment that records data required for investigation of aircraft accidents and should be developed in compliance with the ED-112A standard. Unlike general data storage device, flight data recorder must be able to recover data after an aircraft accident, requiring a housing and a memory board to protect data in extreme environments. To attain this performance, we designed a housing that can withstand the test by analyzing the physical environment of the impact, shear/tensile, penetration resistance and static crush test of the crash survival test and minimized the size and weight compared to the existing one in consideration of the installation of the aircraft in this paper. Insulation material and thermal block material were applied to endure high and low temperature fire so that the internal temperature does not rise above 150℃ even in 260℃, 10 hour environment. In addition, the memory board is designed to minimize the size and we devise a hoping programming method to prevent continuous data loss of more than 16 seconds. Through this, Crash protected memory module that satisfies ED-112A was completed.

Developing of Forest Fire Occurrence Danger Index Using Fuel and Topographical Characteristics on the Condition of Ignition Point in Korea (산불발화지점의 임상 및 지형특성을 이용한 산불발생위험지수 개발)

  • Lee Si-Young;Won Myoung-Soo;Han Sang-Yoel
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.75-79
    • /
    • 2005
  • This study has developed Forest Fire Occurrence Danger Index (FFODI) using fuel and topographical characteristics for the practical purposes of forecasting forest fire occurrence danger rating. This was made on the basis of the 126 forest fire site according to field survey. The result of fire frequency analysis showed 87 sites on conifer $(69\%)$, 21 on mixed $(16.7\%)$ and 18 $(14.3\%)$ on non-conifer. The scale for Fuel Model Index(FMI) ranges from 1 to 10 and Topography Model Index(TMI) from 1 to 5. FMI is 10 on the conifer, 3 on the mixed and 2 on the non-conifer. In case of topographical analysis, it was estimated that 90 site $(71.4\%)$ of ignition point was bottom foot hill and 22 site $(17.5\%)$ was on the southwest. TMI in southwest direction is 5.0, 4.5 in the northwest and the northeast, 4.0 in the southeast and the south, 2.5 in the north and the west and 1.5 in the east. TMI in the bottom foot hill is 5 in the bottom foot hill, 1.5 in the upper foot hill, 1.0 in the bottom middle slope and 0.5 in the upper middle slope and bottom ridge.

Efficacy and Usability of Patient Isolation Transport Module for CBRN Disaster : A Manikin Simulation Study (특수재난 대응 환자 격리 이송 장비의 효율성 및 편의성 평가: 마네킹시뮬레이션 연구)

  • Kim, Ki-Hong;Hong, Ki-Jeong;Haam, Seung-Hee;Choi, Jin-Woo
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • In Chemical, Biological, Radiological and Nuclear (CBRN) disaster, integrated and optimized equipment package including stretcher, isolation unit, patient monitoring and treatment equipment is essential to achieve proper treatment and prevent secondary contamination. The purpose of this study was to evaluate the efficiency and ease of use of integrated CBRN disaster equipment package for disaster medical response. This study was a randomized crossover study using a manikin simulation for emergency medical technitian (EMT). All participants used the existing devices and prototype of integrated CBRN disaster equipment package alternately. Efficiency was measured by time from vital sign change to detection or treatment application. Ease was use was measured by questionnaires for each patient monitor, stretcher care and isolation unit. 12 EMTs were enrolled. hypoxia-detection time of integrated equipment group was significantly shorter than existing equipment group (4.9 s (3.8-3.9) vs 3.5 s (2.5-3.9), p < 0.05). There was decreasing tendency of ECG change detection and facial mask oxygen supply but no statistical significance was observed. Overall satisfaction of patient monitoring device in integrated equipment group was significantly higher than existing devices (4(3.5-5) vs 3(3-3), p < 0.05). The use of integrated CBRN disaster equipment package shortened the hypoxia detection time and improved usability of vital sign monitor compared to existing devices.

Evaluation of Smoke Risk and Smoke Risk Rating for Combustible Substances from Fire (화재로부터 연소성 물질에 대한 연기위험성 및 연기위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui;You, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.197-204
    • /
    • 2021
  • This study investigated the smoke risk assessment of woods and plastics for construction materials, focusing on the smoke performance index-V (SPI-V), smoke growth index-V (SGI-V), and smoke risk index-VI (SRI-VI) according to a newly designed methodology. Spruce, Lauan, polymethylmethacrylate (PMMA), and polycarbonate (PC) were used for test pieces. Smoke characteristics of the materials were measured using a cone calorimeter (ISO 5660-1) equipment. The smoke performance index-V calculated after the combustion reaction was found to be 1.0 to 3.4 based on PMMA. Smoke risk by smoke performance index-V was increased in the order of PC, Spruce, Lauan and PMMA. Lauan and PMMA showed similar values. The smoke growth index-V was found to be 1.0 to 9.2 based on PMMA. Smoke risk by smoke growth index-V increased in the order of PMMA, PC, Spruce, and Lauan. COpeak production rates of all specimens were measured between 0.0021 to 0.0067 g/s. In conclusion, materials with a low smoke performance index-V and a high smoke growth index-V cause a high smoke risk from fire. Therefore, it is understood that the smoke risk from fire is high. It is collectively summarized by the smoke risk index-VI.

Development of Scenario for Utilization in Education of Disaster Response Robots and Effective Analysis of its Application (재난안전로봇의 교육적 활용을 위한 시나리오 개발 및 그 활용의 효과분석)

  • Kang, Ung Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.160-166
    • /
    • 2021
  • In this study, we aim to develop a scenario for educational utilization of disaster response robots that can be used at fire sites and analyze the effectiveness of scenarios according to robot utilization education. Our scenarios were developed based on direction, reality, and rationality determined through the use of a questionnaire survey distributed to current firefighters. In addition, the educational utilization of disaster response robots and training effectiveness were analyzed through repetitive robot control training by a robot development team, current firefighters, and college students. Robot control was divided into direct control, monitor control, and simulation control, and tests were carried out five times. As a result of the analysis of the robot control test, the average time spent for each group was 28 seconds for college students, followed by development teams (30second) and incumbent firefighters (38second). According to the individual analysis results, firefighters (maximum 35second) in direct control, the development team (maximum 14second) in monitor control, and firefighters (maximum 22second) in simulation control showed the effect of shortening control time. These results show that robot control education and training is necessary for robots to be used more effectively at disaster sites.