• Title/Summary/Keyword: 형태측정

Search Result 6,419, Processing Time 0.043 seconds

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

The Effect of Perceived Risk, Scarcity Message in the CATV Homeshopping Ad, and Purchasing Experience on CATV Homeshopping Consumers Response (케이블 TV홈쇼핑 프로그램에서 지각된 위험과 희소성 메시지가 이용경험이 다른 소비자의 반응에 미치는 영향에 관한 연구)

  • Lee, Kyu-Wan;Koo, Ja-Eun
    • Korean journal of communication and information
    • /
    • v.32
    • /
    • pp.209-245
    • /
    • 2006
  • This study examines primarily the effects of perceived risk and scarcity massage on consumers in CATV homeshopping. For consumers, the perceived risk is the cause of delaying purchase decision in CATV Homeshopping while scarcity message in the Ad facilitate purchasing intention in the CATV homeshopping. And another important characteristic of consumer which exerts impact on the response of consumer to the Ad and the product is the frequency of purchasing experience. Thus the purpose of this study is to test the effect of 3 factors on consumer's response to homeshopping Ad and product: one is perceived risk, another is scarcity message and the third is consumer's difference in purchasing. And these are defined as independent variables. The responses of the consumer, the dependent variables of this test are measured in three dimensions; 1) the purchasing intention of the product, 2) the attitude toward the Ad, and 3) the attitude toward product of the consumer. 110 housewives are sampled and assigned to 4 experimental groups. All the groups first watched a video-taped homeshopping Ad messages, and then filled up their responses on the administered questionnaire. The results of this study shows as follows: 1) Perceived risk has negative effect to consumer response. 2) Scarcity message has positive effect to consumers response. 3) But especially perceived risk has negative effect to high frequency purchasing experience group. 4) Scarcity message has also negative effect to high frequency purchasing experience group. 5) The interaction effect of perceived risk and scarcity message is most prominent to the consumers of high frequent purchasing experience.

  • PDF

Fabrication of Label-Free Biochips Based on Localized Surface Plasmon Resonance (LSPR) and Its Application to Biosensors (국소 표면 플라즈몬 공명 (LSPR) 기반 비표지 바이오칩 제작 및 바이오센서로의 응용)

  • Kim, Do-Kyun;Park, Tae-Jung;Lee, Sang-Yup
    • KSBB Journal
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • In the past decade, we have observed rapid advances in the development of biochips in many fields including medical and environmental monitoring. Biochip experiments involve immobilizing a ligand on a solid substrate surface, and monitoring its interaction with an analyte in a sample solution. Metal nanoparticles can display extinction bands on their surfaces. These charge density oscillations are simply known as the localized surface plasmon resonance (LSPR). The high sensitivity of LSPR has been utilized to design biochips for the label-free detection of biomolecular interactions with various ligands. LSPR-based optical biochips and biosensors are easy to fabricate, and the apparatus cost for the evaluation of optical characteristics is lower than that for the conventional surface plasmon resonance apparatus. Furthermore, the operation procedure has become more convenient as it does not require labeling procedure. In this paper, we review the recent advances in LSPR research and also describe the LSPR-based optical biosensor constructed with a core-shell dielectric nanoparticle biochip for its application to label-free biomolecular detections such as antigen-antibody interaction.

Translucency of ceramic veneers on glazing effect (세라믹 비니어의 글레이징에 따른 반투명도 변화)

  • Kim, Sung-Joon;Kahm, Se Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.138-143
    • /
    • 2015
  • Purpose: The aim of this study was to compare the translucency of two different laminate ceramic veneers with and without glazing. Materials and methods: Ten millimeter side square-shaped specimens in 0.3 mm and 0.6 mm thick were fabricated for the following materials with and without glazing (n=80): A1 shade IPS e.maxPress (IEM) and Styleveneers (STV). The color coordinates (CIE $L^*a^*b^*$) of the specimens were measured with a colorimeter. The Translucency parameter (TP) was calculated from the color difference of the material on a black versus a white background. For comparisons between materials and between the 'not glazed' and 'glazed' groups, unpaired t-test was used to analyze the data (P=.05). Results: The TP ($Mean{\pm}SD$) of 'not-glazed' and 'glazed' group of IEM specimens at 0.3 mm thickness were $45.99{\pm}3.00$ and $49.53{\pm}2.28$ and the TP at 0.6 mm thickness were $32.82{\pm}2.59$ and $43.02{\pm}0.98$, respectively. Likewise, the TP of 'not-glazed' and 'glazed' group of STV specimens at 0.3 mm thickness were $47.03{\pm}3.65$ and $50.95{\pm}3.05$ and the TP at 0.6 mm thickness group were $34.48{\pm}1.28$ and $43.39{\pm}1.20$, respectively. As the glazing of ceramic veneer differed, the TP of each ceramic veneer showed statistically significant difference. But, the result between the products was not statistically different. Conclusion: Within the limitations of this study, we are concluded that the glazing process changed translucency of laminate ceramic veneers and the TP would not be affected by products.

An experimental study of cutting efficiency of air-driven diamond burs on human tooth (수종 air-turbine 다이아몬드 버의 절삭 효과에 관한 실험적 연구)

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the cutting efficiency of coarse grit diamond burs with air-turbine handpiece on natural tooth. Materials and methods: Four groups of coarse grit diamond bur were selected: Komet (A), Shofu (B), Premier (C), and Mani (D). The extracted maxillary central incisors were used, and ten cuts were made on each specimen, using the rotary diamond burs. The surface of each bur was measured at the upper, middle, and bottom of the bur with confocal laser scanning microscope and imaged with SEM. The data were analyzed with one-way ANOVA and t-test at the significance level of 0.05. Results: The surface roughness was measured. At the A diamond bur, the Sa values were $52.93\;{\mu}m$, $48.32\;{\mu}m$, $46.79\;{\mu}m$, $45.06\;{\mu}m$, and $43.43\;{\mu}m$ for control, test 1, 2, 3, and 4 respectively. The Sa values were $50.68\;{\mu}m$, $45.62\;{\mu}m$, $44.41\;{\mu}m$, $44.10\;{\mu}m$, and $42.46\;{\mu}m$ for B diamond bur, $58.02\;{\mu}m$, $55.53\;{\mu}m$, $52.22\;{\mu}m$, $48.26\;{\mu}m$, and $45.36\;{\mu}m$ for C diamond bur, and $50.11\;{\mu}m$, $46.73\;{\mu}m$, $45.46\;{\mu}m$, $42.58\;{\mu}m$, and $41.80\;{\mu}m$ for D diamond bur. Surface roughness after each bur use showed significant changes, but no significant difference was found in surface roughness change between bur systems. Conclusions: Surface roughness in the same bur system showed significant differences after each tooth preparation. However no statistically significant differences were found in surface roughness between bur systems. The SEM images between control and test 4 showed the abraded particles.

Effect of Saengshik on Blood Glucose Response in Healthy Subjects (생식조성이 정상성인의 혈당반응에 미치는 영향)

  • Kim, Hwa-Young;Hong, Seong-Gil;Hwang, Sung-Ju;Mok, Chul-Kyoon;Park, Mi-Hyoun;Lee, Ju-Yeon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.12
    • /
    • pp.1553-1559
    • /
    • 2007
  • The purposes of this study were to investigate the effect of Saengshik on blood glucose level of normal subject and to explore the marketing possibility of four kinds of Saengshik (ES, HS, BS, SS) as alternative diabetic meals. Blood glucose levels of healthy volunteers was measured at 15, 30, 45, 60, 75, 90, 105 and 120 minutes after taking Saengshik and 50 g glucose. Blood glucose response areas, glycemic index (GI) and glycemic load (GL) were calculated from the glucose response. The Saengshik showed a significantly lower glucose level than the glucose. The glycemic index (GI) of ES showed $43.1{\pm}12.6$, which belonged to low GI foods (GI of 55 or less). Other samples (HS, BS, SS) could be classified as intermediate GI foods ranging $56{\sim}69$ of GI. Saengshik showed a gentle rising and falling pattern showing moderate left area ratio and right area ratio on blood glucose curve. The GL of ES showed 14.1 while HS, BS and SS did $19.2{\sim}19.5$. The results indicated that Saengshik may have a beneficial effect on a diabetic.

The Family Relationship Scale : Re-validation ("가족관계척도" 활용을 위한 타당도 연구)

  • Yang, Ok-Kyung;Lee, Min-Young
    • Korean Journal of Social Welfare
    • /
    • v.54
    • /
    • pp.5-33
    • /
    • 2003
  • This study is about the re-validation evaluation of the family Relationship Scale (FRS), developed to measure the family relationship in the social work practice. This study aims at re-validating the FRS, developed and validated in by Yang in 2001 for more general utilization. The sample was married mates and females residing in Seoul. For Face Validity, the content analysis was performed, and the FRS was re-validated in the dimensions of Love & Caring, Acceptance, and Recognition, positive affection, empathy, and autonomy and flexibility for each area. Internal reliability was .93, and internal consistency among three dimensions was 93%. For Empirical Validity, the Construct validity, the Criterion validity, and the Discriminant validity were performed. Construct Validity was validated through factor analyses. Commonalities for the factor analysis was 54%, and the factor loading for each factor was over .45. The confirmative factor analysis also confirmed the fitness of the scale. For Predictive Validity of Criterion Validity, regression analysis showed that the family stress scores became lower as the scores of the family relationship became higher; the discriminant analysis revealed that the family stress turned low ill tile group of high scores of family relationship. The Correlation analysis for Concurrent Validity was performed and the results showed the positive and significant relationship with a couple communication level (r=54) and a parent-child communication level (r=64). Life satisfaction and mental health level also revealed significantly positive correlation to prove Convergent Validity. Physical health level revealed a weak relationship with family relationship providing the evidence of Discriminant Validity. Discriminance was also proved by the analysis of variance with demographics. Thus, Cross Validation was confirmed the validation of the FRS through the various analyses with the married population. This study result improved the validity generalization of the Scale and verify the generalized usage of this sociometric scale in the field of social work practice.

  • PDF

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Corrosion Rate of Structural Pipes for Greenhouse (온실 구조용 파이프의 부식속도 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Lee, Si Young;Moon, Sung Dong;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.333-340
    • /
    • 2015
  • Because soils in reclaimed lands nearby coastal areas have much higher salinity and moisture content than soils in inland area, parts of greenhouses embedded in such soils are exposed to highly corrosive environments. Owing to the accelerated corrosion of galvanized steel pipes for substrucrture and structure of greenhouses in saline environments, repair and reinforcement technologies and efficient maintenance and management for the construction materials in such facilities are required. In this study, we measured the corrosion rates of the parts used for greenhouse construction that are exposed to the saline environment to obtain a basic database for the establishment of maintenance and reinforcement standards for greenhouse construction in reclaimed lands with soils with high salinity. All the test pipes were exposed to soil and water environments with 0, 0.1, 0.3, and 0.5% salinity during the observation period of 480 days. At the end of the observation period, salinity-dependent differences of corrosion rate between black-surface corrosion and relatively regular corrosion were clearly manifested in a visual assessment. For the soils in rice paddies, the corrosion growth rate increased with salinity (0.008, 0.027, 0.036, and $0.043mm{\cdot}yr^{-1}$ at 0, 0.1, 0.3, and 0.5% salinity, respectively). The results for the soils in agricultural fields are 0.0002, 0.039, 0.040, and $0.039mm{\cdot}yr^{-1}$ at 0, 0.1, 0.3, and 0.5% salinity, respectively. The higher corrosion rate of rice-paddy soil was associated with the relatively high proportion of fine particles in it, reflecting the general tendency of soils with evenly distributed fine particles. Hence, it was concluded that thorough measures should be taken to counteract pipe corrosion, given that besides high salinity, the soils in reclaimed lands are expected to have a higher proportion of fine particles than those in inland rice paddies and agricultural fields.

An Estimate of Ballast Track Condition on Dynamic Behavior of Railway Bridge (철도교량의 동적거동 특성을 고려한 자갈도상궤도의 상태추정에 관한 연구)

  • Kweon, Oh-Soon;Choi, Jung-Youl;Kang, Myoung-Seok;Lee, Hee-Up;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.480-493
    • /
    • 2007
  • Many railway-advanced countries are using the various types of track to reduce the track maintenance and repair cost according to the improvement of velocity. It spends on much maintenance and repair cost for ballast track due to abrasion of ballast, track irregularity and unisotropical ballast-support stiffness. The ballast track on railway bridge is accelerating the deterioration of ballast according to interaction of railway bridge and track. As continuing the deterioration, it is caused dynamic loads. Due to these effects, it increases negative loads of track and bridge. However, when designing the railway bridge, the effect of ballast track was applicate only dead load, so elastic behavior effect of ballast track is not influenced. Therefore, this paper presumes the stiffness of ballast track on railway bridge considering dynamic behavior of railway bridge, it was evaluated that effect on dynamic behaviors of railway bridge according to ballast track stiffness.

  • PDF