• Title/Summary/Keyword: 혈관 조영술

Search Result 336, Processing Time 0.031 seconds

CT Findings and Accuracy of Preoperative Pathologic Diagnosis in Bronchial Carcinoid According to Subtype (기관지 유암종의 아형에 따른 CT 소견과 수술전 병리학적 진단의 정확성)

  • 임준석;홍용국;정경영;최규옥
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.380-387
    • /
    • 1998
  • We evaluated CT findings of bronchial carcinoid and accuracy of preoperative pathological diagnosis according to two subtypes. The subjects were 10 cases(typical;5, atypical;5), confirmed by surgery and tissue pathology. Sputum cytology(n=10), percutaneous aspiration(n=1) and bronchoscopic biopsy (n=8) were performed, preoperatively. The CT findings were analysed according to two subtypes. Typical carcinoid shows central location in all, and bronchial lumens just proximal to tumor were widened in two, whereas atypical carcinoid presented as peripheral leison in two. Among central atypical carcinoid, two cases showed flat meniscus appearance of lumen. Remaining one showed diffuse wall thickening. Intratumoral low density by necrosis was noted in one. Both subtypes show contrast enhancement. For preoperative diagnosis, sputum cytology & percutaneous aspiration were not conclusive at all. As for bronchoscopic biopsy, only 3 cases were accurately diagnosed as typical carcinoid. Typical carcinoid presented as endobronchial mass in all, whereas atypical carcinoid presented in various appearance. In all atypical & some typical carcinoid were misdiagnosed as primary lung cancer, preoperatively. However, in typical carcinoid, conservative surgery was possible. In conclusion, if there is discrepancy between CT findings & preoperative pathological diagnosis, full understanding of CT findings of bronchial carcinoid is imperative to choose appropriate surgical modality.

  • PDF

Routine Off-pump Total Arterial Coronary Revascularization (심폐바이때스 없이 시행된 동맥 도관만를 이용한 관상동맥 완전 재관혈화)

  • Lee, Jae-Won;Park, Nam-Hee;Kang, Seong-Sik;Choo, Suk-Jung;Park, Seung-Jung;Park, Seung-Wook;Hong, Myeong-Ki;Song, Hyun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.309-315
    • /
    • 2003
  • Background: To avoid the adverse effects of cardiopulmonary bypass and to overcome late vein graft failure we routinely peformed off-pump total arterial coronary revascularization. Material and Method: From July 2000 to August 2001, 104 consecutive patients underwent first elective off-pump total arterial coronary revascularization. Both internal mammary, radial and gastroepiploic arteries were used. Sequential and composite grafts were used to achieve complete revascularization. Perioperative adverse events and postoperative angiograms were analyzed. Result: A total of 252 arterial conduits were used with an average of 2.47 grafts per patient. A total of 326 distal anastomosis were performed with a mean of 3.13 distal anastomosis per patient. Cross over to on-pump occurred in seven patients (6.7%). Of these 4 were due to unstable hemodynamics during lateral or posterior wall stabilization as a result of cardiomegaly and 3 were due to uncontrolled bleeding during dissection of diffusely dimunitive deeply placed intramyocardial coronary arteries. There were no opeartive deaths. Two cases of perioperative myocardial infarction and transient neurologic complications occurred, respectively. Of the 312 distal anastomoses, 308 (98.7%) were compatible with Fitz-Gibboll A or B patency grading. Conclusion: Off-pump total arterial coronary revascularization was technically feasible in most elective cases with satisfactory early results. However, on-pump coronary bypass surgery should be considered in difficult circumstances, such as cardiomegaly or unfavorable anatomy of the target coronary artery.

Analysis of Risk Factors in Coronary Artery Bypass Surgery (관동맥우회술의 위험인자 분석)

  • 정태은;한승세
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1049-1055
    • /
    • 1998
  • Background: Coronary artery bypass surgery is an important treatment for ischemic heart disease. Recently operative mortality and morbidity has decreased, however further improvement is necessary. Materials and methods: This study was designed to evaluate the risk of operative mortality and morbidity by retrospective method. From 1992 to 1997, eighty six patients underwent coronary artery bypass surgery. There were 61 males and 25 females aged 36~74 years(mean, 58.6). Fourteen patients(16%) had previous PTCA or stent insertion, 41 patients(48%) had unstable angina, and 45 patients(52%) had three vessel disease. Patients with low LV ejection fraction(<35%) were 7 cases and urgent or emergent operation were 10 cases. There were 6 cases of combined surgery which were mitral valve replacement(2 cases), aortic valve replacement(2 cases), ASD repair(1 case), and VSD repair(1 case). Average number of distal anastomosis was 3.5 per patient and average aortic cross clamp time was 115±38.3min. Preoperative risk factors were defined as follows: female, old age(>70 years), low body surface area(<1.5M2), PTCA or stent insertion history, hypercholesterolemia, smoking, hypertension, DM, COPD, urgent or emergent operation, left main disease, low LV ejection fraction(<35%), and combined surgery. Results: Operative mortality was 7cases(8%). As a postoperative morbidity, perioperative myocardial infarction was 6 cases, cerebrovascular accident 6 cases, reoperation for bleeding 5 cases, acute renal failure 4 cases, gastrointestinal complication 3 cases, and mediastinitis 3 cases. In the evaluation of operative risk factors, low body surface area, DM and low LV ejection fraction were found to be predictive risk factors of postoperative morbidity(p<0.05), and low ejection fraction was especially a risk factor of hospital mortality(p<0.05). Conclusions: In this study, low body surface area, DM and low LV ejection fraction were risk factors of postoperative morbidity and low ejection fraction was a risk factor of hospital mortality.

  • PDF

Computerized Quantative Analysis of Cornary Angiogram in Patients without Coronary Pathology (Computer System을 이용한 정상 관상동맥 조영 사진의 양적분석)

  • Yun, Yang-Koo;Park, Kay-Hyun;Choi, Young-Soo;Kim, Kwhan-mien;Jun, Tae-Gook;Kim, Jhin-gook;Shim, Young-Mog;Park, Pyo-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.488-493
    • /
    • 1998
  • In the preoperative evaluation before coronary artery bypass surgery, review of the coronary arteriogram is the most important step. Expected "normal" lumen diameter at a given coronary anatomic location is a basis for quantative estimation of coronary disease severity that could be more useful than the traditional "percent stenosis". The distribution and number of major coronary artery branches are determinants of number of bypass grafts needed. We reviewed the coronary artery anatomy in 174 adult patients who revealed no coronary pathology in angiographic studies done from September 1994 to June 1996. Quantative analysis was done in all cases by a single person using a Computerized System (Arripro 35ⓡ). The results were follows; 1) The mean diametre of left main coronary artery was 4.45 mm(range 2.74~6.72). The pattern of branching was bifurcation in 67.24%, trifurcation in 28.74% and quadrifurcation in 4.02% of the patients. 2) The mean diametre of left anterior descending artery was 3.17 mm(range 2.10~5.85), 2.79 (range 1.55~5.59) and 2.17 mm(range 1.37~3.81) in the proximal, mid, and the distal portions, respectively. The number of diagonal branches of left anterior artery was from one to four(mode=2). 3) The mean diametre of proximal and distal left circumflex artery were 3.17mm(range 1.74~4.89) and 2.19 mm(range 1.21~4.46). The number of obtuse marginal branches of left circumflex artery is from one to six(mode 2). 4) The mean diametre of proximal and distal right coronary artery, the posterior descending artery and the largest posterolateral branch were mean 3.51 mm(range 2.07~5.67), 2.09 mm (range 1.42~3.60), 2.09 mm(range 1.02~3.60) and 2.30 mm(range 1.39~4.39). 5) The right coronary artery dominant was 163 cases(93.68%) of the total 174 cases. 6) The large significant acute marginal artery was visualized in more than half of the people. half of the people.

  • PDF

Saphenous Vein Graft as a Composite Graft in Patients Who Are Undergoing Off-pump Coronary Artery Bypass: The Early Results (복재정맥 복합도관을 이용하여 시행한 심폐바이패스를 사용하지 않는 관상동맥우회술의 조기 결과)

  • Hwang, Ho-Young;Kim, Jun-Sung;Choi, Eun-Seok;Lee, Jae-Hang;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.324-330
    • /
    • 2009
  • Background: The long term patency of the free saphenous vein graft, which is the most commonly used conduit, anastomosed to the ascending aorta has been reported to be lower than that of arterial grafts. We evaluated early clinical outcome and the angiographic patency of the saphenous vein composite graft based on the left internal thoracic artery, and compared these results with those of using arterial composite grafts. Material and Method: From September 2006 to October 2008, 419 patients underwent off-pump coronary revascularization. Among those, 295 patients (70.4%) were revascularized using composite grafts (group I: saphenous vein composite graft, n=71, group II: arterial composite graft, n=224). The clinical results were compared between the 2 groups. Early postoperative coronary angiograms were performed in all the patients. ($1.6{\pm}1.6$ days) Result: The number of the distal anastomosis per patient was $3.5{\pm}1.0$ and $3.1{\pm}0.8$ in group I and II, respectively (p=.002). The operative mortality (n=2, 0.7%) and postoperative complications such as atrial fibrillation (n=73, 24.7%), perioperative myocardial infarct (n=6, 2.0%), acute renal failure (n=6, 2.0%), reoperation for bleeding (n=5, 1.7%), cerebrovascular accident (n=3, 1.0%), and mediastinitis (n=1, 0.3%) were not related with the use of saphenous vein graft. Early coronary angiograms revealed a 96.9% (126/130) for the saphenous vein grafts and a 98.8% (479/485) for the composite graft in group II (p=.231). Conclusion: Our data suggested that a saphenous vein graft might be used as analtemative conduit to the arterial graft for constructing a composite graft, as based on our early clinical and angiographic results. Further study is required to establish the long-term efficacy of using a saphenous vein as a composite graft.

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Central Nervous System Complications of Coronary Artery Bypass Grafting - Comparison Between Off-Pump CABG and Conventional CABG (관상동맥 우회술 후의 중추신경계 합병증 - 심폐바이패스를 사용하지 않은 관상동맥 우회술과 기존의 관상동맥 우회술의 비교)

  • Chang, Ji-Min;Lee, Jeong-Sang;Kim, Ki-Bong;Ahn, Hyuk;Yoon, Byung-Woo;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.33 no.12
    • /
    • pp.941-947
    • /
    • 2000
  • Background: Central nervous system complication after coronary artery bypass grafting(CABG) is one of the major prognostic determinants and the use of the cardiopulmonary bypass(CPB) may increase the incidence of this devastating complication. In this study, the outcomes after off-pump CABG were studied and compared with those following the conventional CABG using CPB. Material and Method: Among the consecutive isolated CABG's performed in SNUH during Feb. 1995 and Jun. 1999, 338 coronary artery bypass grafting were divided into two groups. 223 patients underwent CABG using the CPB(Group I), and 115 patients underwent CABG without CPB(OPCAB)(Group II). All patients enrolled in this study received extensive preoperative examinations including thorough neurologic examination before and after surgery, transcranial doppler study, carotid duplex ultrasonography, and magnetic resonance angiography if necessary. Central nervous system(CNS) complications were defined as stroke, seizure, metabolic or hypoxic encephalopathy and transient delirium after surgery. Result: There were 61 cases(27.3%) who developed postoperative CNS complication in Group I, whereas 8 cases(7.0%) of CNS complications developed postoperatively in group II(p<0.05). Statistically significant predictors of postoperative CNS complications in group I were age and the use of cardiac assist devices perioperatively. Conclusion: This study suggested that omitting the use of CPB in CABG resulted in significant decrease of the postoperative CNS complications. OPCAB should be more widely applied especially to the elderly who have preexisting cerebrovascular disease.

  • PDF

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

The Clinical Significance of Measurement of Serum Vascular Endothelial Growth Factor in Patients with Hemoptysis (객혈환자에서 혈청 Vascular Endothelial Growth Factor 검사의 유용성)

  • Lo, Dae-Keun;Kim, Seung-Joon;Lee, Sook-Young;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.137-144
    • /
    • 2002
  • Background: Hemoptysis is an often alarming presenting symptom and VEGF is a major regulator of both normal and abnormal angiogenesis, including many inflarrunatory diseases. In this report the clinical significance of the serum VEGF level in patients with hemoptysis was investigated. Methods: Thirty-two patients with hemoptysis were evaluated. The estimated amount of hemoptysis, etiology and serum VEGF level was examined at admission and bronchial angiography was performed in 22 patients. In order to objectify the neovascularization status, one point for the presence of the A-V shunt, hypervascularity, vascular tortuosity was designated for a total of 0-3 points. Results: Mean quantity of hemoptysis was $172.4{\pm}270.4ml$. The mean angiographic neovascularization score was $1.23{\pm}0.75$. The serum VEGF level correlated with the quantity of hemoptysis(r=0.524, p=0.002) and with the angiographic neovascularization score(r=0.441, p=0.04). Using the standard diagnostic criterion for massive hemoptysis, the serum VEGF level of patients with massive hemoptysis($642.4{\pm}545.6$ pg/ml, n=13) was found to be higher than that of patients with non-massive hemoptysis($394.6{\pm}225.8$ pg/ml, n=19) (p=0.069). Conclusion: Regardless of the etiology, the serum VEGF may contribute to abnormal neovascularization in patients with hemoptysis. Therefore, it is suggested that serum VEGF measurements may help in predicting a massive hemoptysis.

Right Gastroepiploic Artery Spasm during Pst-CABG Coronary Angiography (우위대동맥을 이용한 관상동맥 우회술을 시행받은 환자에서 관상동맥 조영술증 발생한 우위대망동맥의 경련)

  • Song, Hyun;Lim, Han-Jung;Lee, Cheol-Whan;Hong, Myeong-Ki
    • Journal of Chest Surgery
    • /
    • v.33 no.5
    • /
    • pp.428-431
    • /
    • 2000
  • In the mid 1980's, the ITA(internal thoracic artery) graft was clearly recognized to be superior to the sapheonous vein graft in respect to long term patency. Therefore, there has been growing interest in the arterial conduit with the possibility of improving the long term result. We have been performing CABG with GEA since 1998 with the same purpose. For mid-term and long-term follow up, we have been performing postoperative coronary angiography. In this paper, a case of GEA spasm, a purported drawback of this conduit, during postoperative coronary anigiography and relieved by direct infusion of 200$\mu\textrm{g}$ isoket into the GEA is reported. The current case which exemplifies the spastic nature of RGEA is accompanied with coronary angiography.

  • PDF