• Title/Summary/Keyword: 합착

Search Result 38, Processing Time 0.022 seconds

Comparative evaluation of micro-shear bond strength between two different luting methods of resin cement to dentin (합착 술식에 따른 레진 합착제의 상아질에 대한 미세전단결합강도의 비교 연구)

  • Lee, Yoon-Jeong;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.283-293
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of dual bonding technique by comparing microshear bond strength between two different luting methods of resin cement to tooth dentin. Three dentin bonding systems(All-Bond 2, One-Step, Clearfil SE Bond), two temporary cements (Propac, Freegenol) were used in this study. In groups used conventional luting procedure, dentin surfaces were left untreated. In groups used dual bonding technique, three dentin bonding systems were applied to each dentin surface. All specimens were covered with each temporary cement. The temporary cements were removed and each group was treated using one of three different dentin bonding system. A resin cement was applied to the glass cylinder surface and the cylinder was bonded to the dentin surface. Then, micro-shear bond strength test was performed. For the evaluation of the morphology at the resin/dentin interface, SEM examination was also performed. 1. Conventional luting procedure showed higher micro-shear bond strengths than dual boning technique. However, there were no significant differences. 2. Freegenol showed higher micro-shear bond strengths than Propac, but there were no significant differences. 3. In groups used dual bonding technique, SE Bond showed significantly higher micro-shear bond strengths in One-Step and All-Bond 2 (p<0.05), but there was no significant difference between One-Step and All-Bond 2. 4. In SEM observation, with the use of All-Bond 2 and One-Step, very long and numerous resin tags were observed. This study suggests that there were no findings that the dual bonding technique would be better than the conventional luting procedure.

Comparison of Push-out Bond Strengths According to Relining Procedure and Cement Type on Fiber Post (Fiber post의 Relining 방법과 시멘트 유형에 따른 Push-out Bond Strength의 비교)

  • Kang, Hyun-Young;Cho, So-Yeun;Yu, Mi-Kyung;Lee, Kwang-Won;Kim, Kyoung-A
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.253-265
    • /
    • 2011
  • When restoring endodontically treated teeth is the mismatch between fiber post size and post space diameter, the resin cement layer is excessively thick in post space and voids are likely to form in it, thus predisposing to de-bonding. The method to overcome this problem is to reline the fiber post with composite resin. This individual anatomic post improves the adaptation of post to root walls and decreases the resin cement thickness. The purpose of this in vivo study was to evaluate the push-out bond strength of fiber post according to relining procedure and luting agents type used for simplicity of clinical procedure. Forty-two extracted teeth were divides into six groups.(n=7) A1: relined fiber post cemented with Luxacore/all-bons 2, A2: non-relined fiber post cemented with Luxacore/all-bond2, B1: relinind fiber post cemented with Calibra/XP-bond, B2: non-relined fiber post cemented with Calibra/XP-bond, C1: relined fiber post cemented with RelyX Unicem, C2: non-relined fiber post cemented with RelyX Unicem Push-out bond strength was affected by interaction between relining procedure and luting agent type. Relined fiber post presented higher push-out bond strength value than non-relined fiber post and statically significant differences(p<0.05) Cementation with RelyX Unicem showed significantly higher bond strength than other luting agents(p<0.05).

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

AN EXPERIMENTAL STUDY ON MARGINAL LEAKAGE OF THE DENTAL PERMANENT CEMENTS AFFECTED BY THE TEMPORARY CEMENTS (치과용 임시합착 Cement가 영구합착 Cement의 변연누출에 미치는 영향에 관한 실험적 연구)

  • Lee, Hyeog;Lee, Ho-Yong
    • The Journal of the Korean dental association
    • /
    • v.22 no.4 s.179
    • /
    • pp.313-322
    • /
    • 1984
  • This study was designed to observe the marginal leakage of three permanent cements affected by three temporary cements. The temporary cements used in this study were Zinc oxide-eugenol, Non-eugenol, and Calcium hydroxide cements and the permanent cements were Zinc phosphate, Polycarboxylate and Alumina reinforced EBA cements. To measure the dye penetration into permanently cemented zone, the experimental specimens were treated with the temporary cements for a week. An analysis of the data obtained from 120 specimens resulted in the following conclusions: 1. Regardless of the types of the permanent cements used, using Calcium hydroxide cement as temporary cement showed higher marginal leakage than other temporary cements. 2. Using Polycarboxylate cement as permanent cement showed less marginal leakage than other permanent cements. 3. The marginal leakage in zinc phosphate cement was similar to Alumina reinforced EBA cement regardless of the types of the temporary cements.

  • PDF

A technique for fabricating abutment replica with hot melt adhesive material to minimize residual cement in implant restoration: a case report (임플란트 보철 합착 시 잔여 시멘트 최소화를 위해 열가소성 접착제를 이용한 복제 지대주 제작 방법: 증례보고)

  • Seo, Chi-Won;Han, A-Reum;Seo, Jae-Min;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.240-245
    • /
    • 2016
  • Removal of excess cement is important to prevent biological complication in cementation of implant restoration with subgingival margin. It can be difficult to completely remove excess cement. Several techniques have been introduced to minimize excess cement using abutment replica. In this case report, a simple method for making abutment replica with hot melt adhesive material in dental office was described. This technique is simple and effective because it can be used for pre-fabricated or custom abutment without additional laboratory procedure. In addition, it can minimize excess cement after cementation of implant restoration.

A Simulation Model for Vaccum-Driven Bonding of Glass Panels in the Cell Process for LCD Manufacturing (LCD 유리원판 진공식 합착공정 해석을 위한 수치모델)

  • Ji Chul-Wook;Kwak Ho Sang;Kim Kyoung Hoon
    • Journal of computational fluids engineering
    • /
    • v.8 no.2
    • /
    • pp.33-41
    • /
    • 2003
  • A simplified simulation model is designed to investigate the vacuum-driven bonding of glass panels in the cell process for LCD manufacturing. The bonding process is modelled by the transient flow of a weakly-compressible fluid in a very thin channel between two horizontal glass panels. An order of magnitude scaling analysis is conducted based on the characteristic feature of the channel of which height is much smaller than the horizontal length scales. It is revealed that the flow in the channel is represented by a Poiseuille flow of a compressible fluid. A finite volume model has been constructed to acquire the numerical solution to the derived simplified equations. For a simple test problem of pressure-driven microchannel flow, an assessment is made of the accuracy and validity of the proposed model. The basic aspects of vacuum-driven bonding are examined numerically, and the applicability of the present simulation model is illustrated.

Structure and Optical Characteristic Evaluation of Toner Particle Type Display (토너입자형 디스플레이의 구조 및 광특성 평가)

  • Kim, Cheol-Woo;Kim, Young-Cho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.30-31
    • /
    • 2009
  • 전하가 다른 두 종류의 토너입자를 ITO 기판에 격벽 높이의 차이를 두어 제작한 패널을 사용하였다. 토너입자를 충전할 때 동일한 격벽 높이의 패널을 사용하는 것과 서로 다른 패널을 사용하여 합착, 2가지 type을 제작하였다. 제작된 패널을 전압별로 구동하고 각 구동전압에서의 광특성을 측정하였다. 셀 내부에 충전되어 있는 입자보다 운동량이 적은, 즉 셀 내부에서도 격벽 표면에 흡착되어 있는 토너입자들이 구동과 광특성에 어떠한 영향을 미치는지 평가하였다.

  • PDF

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

AN EXPERIMENTAL STUDY OF THE EFFECT OF TEMPORARY CEMENTS ON THE BOND STRENGTH OF PERMANENT CEMENTS (치과용 임시합착 시멘트가 영구합착 시멘트의 결합력에 미치는 영향에 관한 실험적 연구)

  • Lee, Jin-Ho;Lee, Ho-Yong;Han, Dong-Hoo
    • The Journal of the Korean dental association
    • /
    • v.22 no.9 s.184
    • /
    • pp.803-811
    • /
    • 1984
  • The purpose of this study was to research how temporary cementation effected on the bond strength of permanent cementation. Zinc phosphate, polycarboxylate and EBA ZOE cements were used as permanent cements, and as temporary cements Nogenol, Tempak and Dycal were used. The ninety six (96) specimens were prepared to measure the bond strength of permanent cements after treated with temporary cements for one week. The tensile stregths were measured with an Instron Universal Test Machine. The results of this study were obtained as follows: 1. With zinc phosphate cement, there was a tendency that the bond strengths of the group of temporarily cemented with Nogenol were increased, meanwhile they were decreased a little in the groups of Dycal and Tempak than those of the control group. 2. With polycarboxylate cement, there was a tendency that the bond strengths of the Control group were higher than those of experimental groups and they were decreased in order of Tempak, Noginol, and Dycal. 3. With EBA ZOE cement, there was a tendency that the bond strengths of the group of temporarily cemented with Tempak were increased a little, meanwhile they were decreased a little in the groups of Nogenol and Dycal than those of the Control group. 4. Among the permanent cements, the bond strengths of polycarbosylate cement were the highest and were followed in order of zinc phosphate cement and EBA ZOE cement.

  • PDF