• Title/Summary/Keyword: 피폭선량

Search Result 1,153, Processing Time 0.027 seconds

A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure (방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구)

  • Jeon, Mi-Eun;Lim, Cheong-Hwan;Jung, Hong-Ryang;You, In-Gyu;Hong, Dong-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.

Trends and Issues in Metabolism and Dosimetry for Tritium Intake (삼중수소 피폭방사선량 평가의 경향과 이슈에 대한 고찰)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.99-106
    • /
    • 2011
  • Tritium is the one of the most important radionuclide for workers in nuclear power plants (NPPs) and the public, from the dosimetric point of view. Humans are likely to have internal radiation exposure by tritium inhalation. Radiation exposure by tritium accounts for approximately 7% and 60~90% of the total radiation exposure of NPP workers and the public during normal operation, respectively. Thus, many researches have been conducted to estimate the internal dose by tritium precisely in the world. In terms of tritium dosimetry, this paper provides the current status of research for tritium metabolism and dosimetry.

Analysis of Radiation Dose for Lens, Thyroid Gland, Breast, and Gonad on Upper Gastrointestinal Series (위장조영검사에서 수정체, 갑상선, 유방, 생식선에 대한 피폭선량 분석)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.889-894
    • /
    • 2019
  • Upper gastrointestinal series is an examination that uses X-rays. It is important to defend against exposure to radiation during upper gastrointestinal examination because the organs, such as thyroid gland, lens, breasts, and gonads, with relatively high biological sensitivity to radiation are distributed on the examination area. We have made a whole body phantom that can change the depth of organs. radiation dose of eye, thyroid gland, breast and gonads were measured by the same procedure as the actual upper gastrointestinal examination. When performed only fluoroscopy the mean dose reduction of lens, thyroid gland, breast and gonads was 62.2%. The mean dose reduction of lens, thyroid gland, breast and gonads was 59.0% when both fluoroscopy and spot shoot were performed. Therefore, when performed upper gastrointestinal examination it was confirmed that shielding of the lens, thyroid gland, breast and gonads was effective in decreasing the exposure dose. The manufactured human phantom can be used in measuring radiation dose for deep organ because it can adjust the height corresponding to the organs located in the human body.

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

Exposure Dose of DIPS in Proton Therapy for Pediatric Cancer Patients (소아암 환자의 양성자치료 시 DIPS 촬영에 따른 피폭선량)

  • Kim, Jeong-Soo;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.59-64
    • /
    • 2011
  • We investigated the radiation exposure caused by DIPS, which is used to identify accurate repositioning and tumor location in pediatric cancer patients proton therapy. To compare and analyze DIPS condition, 50 pediatric cancer patients who underwent proton therapy were selected in Ilsan K cancer-specialized hospital from March 2007 to October 2009. For DIP exposure, 0.09~1.57 mGy is measured in AP and lateral directions and 23.55 mGy is measured in CSI patients. In whole brain patient, the amount of a day DIP exposure dose was 1.13 mGy. During treatment period, who exposed the biggest DIP dose are whole brain patients, 632.71 mGy is exposed. It is 1.13% of prescribed dose, represented dose is adequate because it is not exceeded 2% of recommended dose. Even though the exposed dose is not exceeded more than 2% of prescribed in DIP exposure, we should recognize the radiation damage and genetic influences to pediatric cancer patients, who is much sensitive to radiation and has longer mean residual life time. Therefore, DIPS guideline for pediatric cancer patients should be indicated to minimize the radiation exposure.

Determination of Dose Correction Factor for Energy and Directional Dependence of the MOSFET Dosimeter in an Anthropomorphic Phantom (인형 모의피폭체내 MOSFET 선량계의 에너지 및 방향 의존도를 고려하기 위한 선량보정인자 결정)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Na, Seong-Ho;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.2
    • /
    • pp.97-104
    • /
    • 2006
  • In recent years, the MOSFET dosimeter has been widely used in various medical applications such as dose verification in radiation therapeutic and diagnostic applications. The MOSFET dosimeter is, however, mainly made of silicon and shows some energy dependence for low energy Photons. Therefore, the MOSFET dosimeter tends to overestimate the dose for low energy scattered photons in a phantom. This study determines the correction factors to compensate these dependences of the MOSFET dosimeter in ATOM phantom. For this, we first constructed a computational model of the ATOM phantom based on the 3D CT image data of the phantom. The voxel phantom was then implemented in a Monte Carlo simulation code and used to calculate the energy spectrum of the photon field at each of the MOSFET dosimeter locations in the phantom. Finally, the correction factors were calculated based on the energy spectrum of the photon field at the dosimeter locations and the pre-determined energy and directional dependence of the MOSFET dosimeter. Our result for $^{60}Co$ and $^{137}Cs$ photon fields shows that the correction factors are distributed within the range of 0.89 and 0.97 considering all the MOSFET dosimeter locations in the phantom.

A Study on the Reduction of Absorbed Dose through the Insertion of a Shielding Material in the Intraoralsensor of Dental Radiography (치과 방사선촬영 시 구내 센서 내 차폐체 삽입을 통한 피폭선량 감소 연구)

  • Kim, A Yeon;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.273-279
    • /
    • 2022
  • In order to reduce the absorbed dose given to the patient during dental radiography, a sensor that inserts a shield into the intraoralsensor was designed. Using the designed sensor, the change in absorbed dose depending on whether or not a shield was used was evaluated. The system used to evaluate the absorbed dose is VEX-S300C from Vatech, and the energy spectrum of X-rays was obtained through SPEKTR simulation based on the irradiation conditions of 65 kV, 3 mA, and 0.15 sec, and the number of photons for each energy was derived. After designing the system through Genat4 Application for Tomographic Emission(GATE) simulation, the energy spectrum obtained was used as a radiation source to calculate the absorbed dose. Lead was used for the shield, and simulations were performed at 0.1 mm thickness intervals from 0.1 mm to 0.5 mm was evaluated. In the case of using an X-ray field with a diameter of 60 mm, the decrease in absorbed dose according to the presence or absence of a shield decreased exponentially as the thickness of the shield increased. In addition, when a 20 mm × 30 mm field was used, the absorbed dose was significantly reduced even when no shield was used, and it was confirmed that the absorbed dose was further reduced when a shield was used.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

A Study on the Radiation Exposure Dose of Clinical Trainees in the Department of Radiology: A Case Study at C University Hospital (방사선(학)과 임상실습생의 수시출입자 피폭선량에 대한 고찰: C 대학병원 사례 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.249-255
    • /
    • 2023
  • In this study, radiation exposure doses were measured in the course of clinical practice of radiation workers, radiological technologists in the radiation-related worker group, and preliminary-radiological technologists who were classified as frequent visitors. Radiological technologists who worked in the radiation area of C University Hospital in Incheon for a year from January 2021 and 121 students who completed clinical practice at the same medical institution from July 1 to August 31 were the subjects of the study. The nominal risk factor based on ICRP 103 was used to evaluate the probability of side effects due to the exposure dose to the lungs, which are organs at risk of damage due to radiation exposure dose. During the clinical practice period, radiology students, who were classified as frequent visitors, had a surface dose of 0.98 ± 0.14 mSv and a deep dose of 0.93 ± 0.14 mSv. In other words, 6.7 per 1,000,000 for shallow dose and 6.4 per 1,000,000 for deep dose were found to have side effects due to exposure to the lungs. This is a value in terms of exposure dose in one year. Considering that the radiation (science) education course is 3 or 4 years, systematic management and attention to prospective radiation workers who are going to clinical practice are required, and the stochastic effect of radiation In relation to this, it is considered that it will be used as basic data for radiation safety management.

Study on Radiation Dose in the Medical Image Data Display Method - Focused on the DICOM Standard (의료영상 데이터에서의 피폭선량 표시 방법에 관한 고찰: DICOM 표준을 중심으로)

  • Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.483-489
    • /
    • 2015
  • DICOM (Digital Imaging and Communications in Medicine) standards are generally introduced as de facto and de jure standards in modern medical imaging devices to store and to transmit medical image information. DICOM Dose Structured Report (DICOM dose SR) is implemented to report radiation exposure information in image acquiring process. and DIOCM Modality Performed Procedure Step (DICOM MPPS) is also partly used to report this exposure with the information in its DICOM tag. This article is focused on three type of radiation exposure information of DICOM standards, 1) DICOM dose SR, 2) DICOM MPPS and 3) Radiation Exposure Monitoring(REM) profile by Integrating the Healthcare Enterprise(IHE), to study on radiation exposure reporting. Healthcare facility and its staff of medical imaging related to radiation exposure should have a deep understanding of radiation exposure, and it required a standards to enhance the quality control of medical imaging and the safety of patients and staffs. Staff member have to pay attention on radiation exposures and controling processes from the purchasing stage of X-ray devices.