• Title/Summary/Keyword: 피난특성

Search Result 220, Processing Time 0.034 seconds

The Rule-based Agent Modeling and Simulation considering the Evacuation Behavior Characteristics on the Passenger Ship Fire (여객선 화재시 피난행동특성을 고려한 규칙기반 에이전트 M&S)

  • Lee, Eun-Bok;Shin, Suk-Hoon;You, Yong-Jun;Chi, Sung-Do;Kim, Jae-Ick
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.3
    • /
    • pp.111-117
    • /
    • 2011
  • This paper suggests the passenger model considered evacuation behavioral characteristics on the passenger ship fire using a rules-based agent technique. The existing evacuation simulation system was modeled only passenger speed. The speed-based model considered passenger's physical characteristics, so it couldn't consider evacuation behavioral characteristics. For solving this problem, we modeled the passenger model using a rule-based agent applied evacuation behavioral characteristics. The rule-based agent consists of knowledge base and inference engine. In knowledge base, we represented evacuation behavioral characteristics, and chose the examples of the evacuation behavioral characteristics to show various patterns of behavior. And we simulated in the IMO MSC/Circ.1238 example 8 and we proved the simulation results could represent variety patterns of human behavior.

Numerical Simulations on Reduction of Toxic Gas Propagation at High-Rise Apartment Building Fires (계단형 공동주택 화재시 독성가스 전파 저감에 관한 수치해석적 연구)

  • Lee, Seong-Chul;Hong, Yi-Pyo;Park, Young-Rok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.255-258
    • /
    • 2008
  • 본 연구에서는 이전의 연구를 통해 계단형 공동주택 화재 시 재실자 피난특성 및 연기거동에 관한 연구를 실물실험을 통해 수행한 바 있으나 이때 야기된 문제점들을 적절한 방재설비를 도입함으로써 일부 해소하고자 하였다. 따라서 본 연구에서는 이전의 연구와 동일한 대상 건물과 조건에서 수치해석을 수행하며 특히 계단실에 방재설비(배연팬 등) 설치 유 무에 따른 독성가스의 전파 특성 및 최상층까지의 도달시간등을 비교 검토하였다. 계단형 공동주택에서 층간에 배연팬이 설치되어 작동되는 경우가 배연팬이 없는 경우보다 약 45%의 CO 방출량을 줄일 수 있을 것으로 판단되지만 1층 출입구를 통해 유입되는 공기량은 배연팬이 없는 경우가 배연팬이 설치되어 작동되는 경우보다 약 23% 크기 때문에 이로 인해 제연풍속의 증가를 가져올 수도 있을 것이다.

  • PDF

A Study on Actual Condition and Efficiency of Evacuation Facility in Multiplex Available Premises (다중이용업소의 피난설비 관련 실태조사 및 효율성에 관한 연구)

  • Park, Jae-Sung;Yoon, Myong-O;Park, Jong-Tae
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2008
  • As multiplex available premises become more complex and diversified due to increasing social and individual demands, the evacuation safety gradually deteriorates exhibiting functional difficulties even in ordinary fires. Considering the limitations of passive evacuation systems such as evacuation stairs and corridors, an evacuation facility must be designed, installed, and maintained the way that it remains fully functional and efficient when fire breaks out. This study tries to identify the issues of evacuation facilities and devise how to improve them by investigating the evacuation facility efficiencies of multiplex available premises and conducting a survey on fire safety attitude.

The Analysis of Evacuation Safety by Smoke Alarm in Housing Fire (주택형화재경보기 작동에 따른 피난안전해석)

  • Choi, Young-Sang;Jeon, Heung-Kyun;Bak, Yeul-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.73-82
    • /
    • 2011
  • This study was performed to analysis the influence of smoke alarm detector on evacuation safety in housing fire. The analysis was conducted by CFAST fire simulation program and building EXODUS evacuation program. The effects of the earlier response time on evacuation safety were investigated by using evacuation simulation program with several steps of different response time and smoke alarm activation time for 4 occupants. The smoke detecter was activated 37.1 second after fire. The first two mortuary were occurred for 170 seconds of response time at the end of living room near exit. But for the 37.1 seconds of response time 4 occupants evacuated safely. From this study, the fire alarm detector is more important for safety evacuation in housing fire.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade (지하상가 출입구 방풍문 설치에 따른 피난안전해석)

  • Choi, Young-Sang;Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • This paper presents a study on the evacuation analysis in underground arcade. In this study, the effect of the exit with a windbreak door has been investigated by using evacuation simulation program (building EXODUS). Also, the simulation has included the impact of smoke, heat and toxic gases by fire simulation program (CFAST). The results were obtained for the conditions of without and with door of the two exit with 1,088 evacuation population. As a results, for non-fire evacuation, there was only a little difference of evacuation time for both conditions. However, for fire emergency evacuation, the evacuation time for the condition with door increased more 110 seconds than for the condition without door. When the auto door not opened, the evacuation time was increased more 670 seconds than for the condition without door. Consequently, in case of fire, the automatic door should be operating by the signal of fire detector and keep open when the fire accidents. To lead the evacuees well to the escape route the luminaries for an emergency exit sign have to be reinforced to the wall and floor around the exit.

A Study on the Walking Speed of Crowd for Safety Evacuation Design of the Elderly (고령자의 피난안전설계를 위한 군집보행속도에 관한 연구)

  • Hong, Hae-Ri;Seo, Dong-Goo;Hasemi, Yuji;Kown, Young-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.19-26
    • /
    • 2011
  • Korea is rapidly becoming an aging society. As a basic research on increasing evacuation safety design at silver facilities, the study was conducted in consideration of different foot's pace according to the number of seniors and their locations in a crowding of ordinary people and seniors all together. When the seniors were located at the front, the pace reduced to 0.81m/s on average. With 10 seniors which covered 50% of the crowd, the pace decreased to 0.85m/s. It is true that Korea has no existing researches on evacuation behaviour, and functions mentioned in its evacuation safety design is lack of practicality. Therefore, it is certainly necessary to secure any data of the evacuation behavior through various studies on seniors' evacuation behaviors.

대규모 복합건축물의 한국형 피난시뮬레이션 개발을 위한 연구

  • Kim, Jae-Hong;Yun, Seong-Min;Jeong, Gi-Taek;Choe, Jin-Won;Lee, Su-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.62-63
    • /
    • 2013
  • 최근 전 세계적으로 여러 가지 목적으로 초고층 및 대형건축물이 급속도로 건설되고 있다. 건축물이 대형화, 고층화 될수록 피난 동선 및 피난 소요시간은 길어지게 된다. 이에 많은 국내 외 연구에서 대규모 건축물에서의 피난안전성평가를 진행하고 있다. 일반적으로 건축물에서의 피난안정성을 평가하기 위해서는 실제 실험의 어려움 등으로 인해 외산 시뮬레이션을 사용한다. 이러한 외산 프로그램들은 국내의 법규 및 특성을 반영하지 못하는 한계가 있다. 따라서 본 연구에서는 대규모 복합건축물의 한국형 피난시뮬레이션 개발을 위한 연구 및 방향을 제시하고자 한다.

  • PDF

A Study on the Comparative Analysis and Utilization of Evacuation Time according to Variation of Modelling of Behavior Modes: Focusing on the Case of Underground Parking Lot (행동모드 변화 모델링에 따른 피난시간 비교분석과 활용방안 연구: 지하 주차장 사례를 중심으로)

  • Gi-gyeong Koo
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.284-292
    • /
    • 2024
  • Purpose: Compared to general fires of the same size, underground parking lot fires are more likely to cause human and property damage and are not easy for firefighters to extinguish fire and save lives. This study attempted to find out how to secure the evacuation safety of parking lot users based on changes in the evacuation simulation behavior mode applied to evaluate the evacuation safety of the object. Method: Simulation for each CASE was performed using the Pathfinder program. Result: it was found that the higher the reference value, the higher the evacuation time, and Behavior showed an increase in time in SFPE mode rather than Steering mode. Priority was able to confirm an increase in time in priority designation rather than non-priority designation. Conclusion: The Required Safe Egress Time (RSET) for evaluating the evacuation safety of underground parking lots and the building evacuation design to ensure evacuation safety should be evaluated and reflected separately from Simulation's Behaviour Mode and Priority.