• Title/Summary/Keyword: 표준세척

Search Result 39, Processing Time 0.033 seconds

Antibacterial and Rinsing Activities Against Potentially Harmful Bacteria in Rice during Rice Flour Production (쌀가루 제분용 백미 내 잠재적 위해 세균에 대한 살균 및 세척 효과)

  • Han, Jae-Kwang;Cha, Min-Hee;Kim, Min-Ju;Kim, Keun-Sung
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.117-122
    • /
    • 2014
  • Rice can be the contaminating with soil-borne bacteria. Furthermore, the contaminated bacteria can be grown during immersion process for produce wet-milled rice flour. Therefore, disinfectants can be added during the immersion process. Antibacterial activities of the natural disinfectant, fermented rice spent water (FRSW), and the chemical disinfectants, chlorine dioxide (CD) and sodium benzoate (SB), were respectively determined when added in pure cultures of target bacteria such as Salmonella typhimurium, Escherichia coli, and Bacillus cereus or when added to immersion water in the immersion process. In addition, rinsing effects for removing bacteria were determined when rice was rinsed with water before and after the immersion process. Antibacterial activities were rapidly increased as increasing amounts of the disinfectants are added to the pure cultures of the target bacteria. Antibacterial activity of CD was the most effective among the three tested disinfectants when added to the pure cultures of the target bacteria, respectively. Those of the same disinfectants were increased when they were increasingly added to the immersion water. However those of the disinfectants were less effective when added to the immersion water. On the other hand, rinsing effects for removing bacteria were the most effective when rice was rinsed only with water without the immersion process. Collectively, rinsing rice with water only was more effective than using disinfectants in the immersion water during rice flour production.

Evaluation of Hygienic Status of University Foodservice Operation using ATP bioluminescence Assay (ATP bioluminescence Assay를 이용한 대학 급식시설의 위생상태 평가에 관한 연구)

  • 박영숙
    • Korean journal of food and cookery science
    • /
    • v.16 no.2
    • /
    • pp.195-201
    • /
    • 2000
  • An investigation was conducted to evaluate the hygienic status of university foodservice operation by using conventional swabbing technique plus standard plate count and ATP bioluminescence assay. The results of the study were as follows: 1) For all kitchen boards, knives, feeding trays, and dish towels tested, there was an overall agreement at 84.7% level between the results obtained using ATP bioluminescence and plate count when using a pass/fail cut-off of 3$\times$ control values for ATP assay and 40 CFU(colony forming unit)/㎠ for plate count. 2) The agrement rate between ATP assay and standard plate count was 87.5% for the samples before use, 29.2% for those during use, and 42.7% for those after cleaning and sanitizing. 3) The plate counts of three university foodservice operations for kitchen board, kitchen knife, feeding tray and dish towel were within the acceptable limits when tested before using. However, none of them were within the acceptable limits when tested during using and after cleaning and sanitizing. 4) Above results suggested that an immediate action needs to be taken to reduce the potential danger of cross-contamination and also effective sanitary control methods needs to be developed to improve the sanitary condition.

  • PDF

Management of Critical Control Points to Improve Microbiological Quality of Potentially Hazardous Foods Prepared by Restaurant Operations (외식업체에서 제공하는 잠재적 위험 식품의 미생물적 품질향상을 위한 중점관리점 관리방안)

  • Chun, Hae-Yeon;Choi, Jung-Hwa;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.30 no.6
    • /
    • pp.774-784
    • /
    • 2014
  • The purpose of this study was to present management guidelines for critical control points by analyzing microbiological hazardous elements through screening Potentially Hazardous Foods (PHF) menus in an effort improve the microbiological quality of foods prepared by restaurant operations. Steamed spinach with seasoning left at room temperature presents a range of risk temperatures which microorganisms could flourish, and it exceeded all microbiological safety limits in our study. On the other hand, steamed spinach with seasoning stored in a refrigerator had Aerobic Plate Counts of $2.86{\pm}0.5{\log}\;CFU/g$ and all other microbiological tests showed that their levels were below the limit. The standard plate counts of raw materials of lettuce and tomato were $4.66{\pm}0.4{\log}\;CFU/g$ and $3.08{\pm}0.4{\log}\;CFU/g$, respectively. Upon washing, the standard plate counts were $3.12{\pm}0.6{\log}\;CFU/g$ and $2.10{\pm}0.3{\log}\;CFU/g$, respectively, but upon washing after chlorination, those were $2.23{\pm}0.3{\log}\;CFU/g$ and $0.72{\pm}0.7{\log}\;CFU/g$, respectively. The standard plate counts of baby greens, radicchio and leek were $6.02{\pm}0.5{\log}\;CFU/g$, $5.76{\pm}0.1{\log}\;CFU/g$ and $6.83{\pm}0.5{\log}\;CFU/g$, respectively. After 5 minutes of chlorination, the standard plate counts were $4.10{\pm}0.6{\log}\;CFU/g$, $5.14{\pm}0.1{\log}\;CFU/g$ and $5.30{\pm}0.3{\log}\;CFU/g$, respectively. After 10 minutes of chlorination treatment, the standard plate counts were $2.58{\pm}0.3{\log}\;CFU/g$, $4.27{\pm}0.6{\log}\;CFU/g$, and $4.18{\pm}0.5{\log}\;CFU/g$, respectively. The microbial levels decreased as the time of chlorination increased. This study showed that the microbiological quality of foods was improved with the proper practices of time-temperature control, sanitization control, seasoning control, and personal and surface sanitization control. It also presents management guidelines for the control of potentially hazardous foods at the critical control points in the process of restaurant operations.

The Comparison of Methods Processing Cells Recovered by Bronchoalveloar Lavage (기관지폐포세척액에서 세포수 측정을 위한 처리방법의 비교)

  • Park, Jae-Seuk;Kim, Jae-Yeal;Lee, Gwi-Lae;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Kim, Young-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.176-183
    • /
    • 1998
  • Background: The total and differential cell count of bronchoalveolar lavage(BAL) fluid are useful assessing activity, prognosis and response to therapy in diffuse interstitial lung disease. But controversy exist as to the appropriate method in processing BAL fluid. Therefore we investigated the effect of gauze filtration, centrifugation and different storage time of BAL fluid on the total and differential cell count. Methods: We obtained BAL fluid from 6 persons with no active lung lesion and divided pooled BAL fluid into several siliconized glass tubes and filtered through 0, 1, 2, 4 folds of cotton guaze(pore size: 1mm), and compared total cell count using hemocytometer after trypan blue staining and differential cell count after Wright-Giemsa staining of cytocentrifuged preparations. And we also counted total and differential cell count after centrifugation(400g for 30 min) and various storage time(2hr, 24hr, and 48hr). Results: There was no difference in total and differential cell count according to folds of gauze filtraion. But without gauze filtration, mucus threads that hampered total and differential cell count were found in 2 cases (33%). Centrifugation resulted in loss of total cell count($24{\pm}18%$) without change in differential cell count. There was no change in total cell count after 2hr storage but significant cell loss was found after 24hr storage time(24hr : $28{\pm}21%$, 48hr : $41{\pm}24%$). However there was no change in differential cell count with 48hr storage time. Conclusion: Total and differential cell count of BAL fluid may be best performed after cotton gauze filtration without centrifugation and within 2 hours.

  • PDF

Evaluation of a Diffusive Sampler for the Measurement of Formaldehyde using Colorimetric Method (흡광광도법을 이용한 포름알데히드 확산측정기의 평가)

  • Yim, Bong-Been;Kim, Sun-Kyu;Jung, Eui-Suk;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.606-613
    • /
    • 2005
  • The badge-type diffusive sampler for the measurement of formaldehyde in indoor air using three types of colorimetric methods such as chromotrophic acid(CTA), 3-methyl-2-benzothiazolinone hydrazone(MBTH), and 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole(AHMT) method. The washing of the collection filter with several cleaning solution was effected with satisfactory results, regardless of the types of cleaning solutions. The concentrations of absorbance solution in each colorimetric method were experimentally determined by considering the sampling rates. The variation blank values in each colorimetric method was below 15%. As compared with CTA and AHMT methods, the reproducibility of MBTH method was excellent and was below 10% relative standard deviation. The collected formaldehyde mass and time-weighted concentration had a good correlation (correlation coefficient > 0.93). The limit of detection and limit of quantitation, and minimum sampling time were closely correlated to the sampling rates for the measurement of formaldehyde in each method.

Phenanthrene Uptake by Surfactant Sorbed on Activated Carbon (활성탄에 흡착된 계면활성제에 의한 Phenanthrene 흡착)

  • Ahn, Chi-Kyu;Woo, Seung-Han;Park, Jong-Moon
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.2
    • /
    • pp.1-11
    • /
    • 2008
  • Phenanthrene uptake by surfactant sorbed on activated carbon was investigated to recycle of surfactant in washed solution for contaminated soil. The partitioning of phenanthrene to the activated carbon coating with Triton X-100 as a surfactant was also evaluated by a mathematical model. Phenanthrene-contaminated soil (200 mg/kg) was washed in 10 g/L of surfactant solution. Washed phenanthrene in solution was separated by various particle loadings of granular activated carbon through a mode of selective adsorption. Removal of phenanthrene was 99.3%, and surfactant recovery was 88.9% by 2.5 g/L of granular activated carbon, respectively. Phenanthrene uptake by activated carbon was greater than that of phenanthrene calculated by a standard model for a system with one partitioning component. This is accounted for enhanced surface solubilization by hemi-micelles adsorbed onto granular activated carbon. The effectiveness factor is greater than 1 and molar ratio of solubilization to sorbed surfactant is higher than that of liquid surfactant. Results suggest that separation of contaminants and surfactants by activated carbon through washing process in soil is much effective than that of calculated in a theoretical model.

Enhancement of Data Retention Time in DRAM through Optimization of Sidewall Oxidation Precleaning (측면산화 프리크리닝의 최소화를 통한 DRAM의 데이터 유지시간 개선)

  • Chai, Yong-Yoong;Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.833-837
    • /
    • 2012
  • This paper proposes a DRAM data retention time enhancement method that minimizes silicon loss and undercut at STI sidewall by reducing the SC1 (Standard Cleaning) time. SC1 time optimization debilitates the parasitic electric field in STI's top corner, which reduces an inverse narrow width effect to result in reduction of channel doping density without increasing the subthreshold leakage of cell Tr. Moreover, it minimizes the electric field in depletion area from cell junction to P-well, increasing yield or data retention time.

A Comparison of Conventional Cytology and ThinPrep Cytology of Bronchial Washing Fluid in the Diagnosis of Lung Cancer (폐암의 진단 검사 중 기관지 세척액에서 ThinPrep검사법과 기존의 세포검사법의 유용성에 대한 비교)

  • Kim, Sang-Hoon;Kim, Eun Kyung;Shi, Kyeh-Dong;Kim, Jung-Hyun;Kim, Kyung Soo;Yoo, Jeong-Hwan;Kim, Joo-Young;Kim, Gwang-Il;Ahn, Hee-Jung;Lee, Ji-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.523-530
    • /
    • 2007
  • Background: A ThinPrep$^{(R)}$ Processor was developed to overcome the limitations of conventional cytology and is widely used to diagnose various cancers. This study compared the diagnostic efficacy of conventional cytology for lung cancer with that of the ThinPrep$^{(R)}$ cytology using the bronchial washing fluid. Methods: The bronchial washing fluid of 790 patients from Jan. 2002 to Dec. 2006, who were suspected of gaving a lung malignancy, was evaluated. Both ThinPrep$^{(R)}$ and conventional cytology were performed for all specimens. Result: Four hundred forty-six men and 344 women were enrolled in this study, and 197 of them were diagnosed with cancer from either a bronchoscopic biopsy or a percutaneous needle aspiration biopsy. ThinPrep$^{(R)}$ cytology showed a sensitivity, specificity, positive predictive value, negative predictive value and false negative error rate of 71.1%, 98.0%, 92.1%, 91.1%, 8.9%, respectively. The conventional cytology showed sensitivity, specificity, positive predictive value, nagative predictive value and false negative error rate of 57.9%, 98.0%, 90.5%, 87.5%, 12.5%, respectively. For central lesions, the sensitivity of conventional cytology and ThinPrep$^{(R)}$ were 70.1% and 82.8%, respectively. Conclusion: ThinPrep$^{(R)}$ cytology showed a higher sensitivity and lower false negative error rate than conventional cytology. This result was unaffected by the histological classification of lung cancer. Therefore, ThinPrep$^{(R)}$ cytology appears to be a useful method for increasing the detection rate of lung cancer in bronchial washing cytology test.

COMPARISON OF ANTIBACTERIAL EFFECT OF Listerine(R) WITH VARIOUS ROOT CANAL IRRIGANTS (수종의 근관세척액과 Listerine(R)의 항균성 비교 연구)

  • Kim, Young-Hun;Kang, Min-Kyung;Choi, Eun-Kyoung;Yang, So-Young;Yang, In-Seok;Kang, In-Chol;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.500-507
    • /
    • 2009
  • The purpose of this study is to compare the antibacterial effect of $Listerine^{(R)}$ on two microorganisms (P. gingivalis and E. faecalis) with various root canal irrigants (NaOCl, CHX, EDTA) and to identify possibility of using $Listerine^{(R)}$ as a root canal irrigant. Porphyromonas gingivalis ATCC 3327 and Enterococcus faecalis ATCC 29212 were used in this experiment. For the test irrigants, 0.5%, 1%, 2.5%, 5.25% NaOCl, 0.1%, 0.2%, 1%, 2% CHX, 0.5M EDTA (18.6% EDTA) and $Listerine^{(R)}$ were prepared. Distiled water was used as control. Two methods-1) Comparison of turbidity in broth and 2) Agar diffusion test-were used to determine the extent of antibacterial effect of $Listerine^{(R)}$ and to compare it with that of NaOCl, CHX, and EDTA. All solutions tested were effective against two bacterial strains compared with control (p < 0.001). Any concentration of NaOCl, CHX, and EDTA showed similarly high effectiveness against all bacterial strains. In all experiment, $Listerine^{(R)}$ showed significantly low antibacterial effect compared with the other root canal irrigants (p < 0.05). In conclusion, the results reflect remarkably low antibacterial effect of $Listerine^{(R)}$ as compared with root canal irrigants in general so it is not suitable for the root canal irrigant.