• Title/Summary/Keyword: 표준불확도

Search Result 183, Processing Time 0.032 seconds

Development of Uncertainty Evaluation Model for Vacuum Measurement Standards (진공측정표준의 불확도 평가모델 개발)

  • Hong, S.S.;Lim, J.Y.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.313-321
    • /
    • 2011
  • The Korea Research Institute of Standards and Science (KRISS) has three major vacuum systems: an ultrasonic interferometer manometer (UIM), a static volume expansion system (SVES), and an orifice-type dynamic expansion system (ODES). For each system explict measurement model equations with multiple variables are respectively given. According to ISO standards, all these system variables errors were used to calculate the expanded uncertainty (U).

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

The Concept of Measurement Uncertainty and the GUM (측정불확도의 개념과 GUM)

  • Jong Wha Lee
    • Journal of the Korean Chemical Society
    • /
    • v.67 no.5
    • /
    • pp.319-332
    • /
    • 2023
  • Ever since the development of the Guide to the Expression of Uncertainty in Measurement (GUM) in 1993, the concept of measurement uncertainty has been considered a core concept in metrology and the importance of proper uncertainty evaluation has continuously been increasing. Unfortunately, few papers in Korean are available that introduce the concept of measurement uncertainty and the GUM correctly and in sufficient detail. This review describes in detail the mathematical, historical, and philosophical background behind the concept of measurement uncertainty and the GUM, and also discusses some special aspects of uncertainty evaluation in chemical analysis.

The Best Measurement Capability for the Standard Test Facility of Water-Level Gauges (수위계 표준시험장치의 최고측정능력 산출)

  • Shin, Gang-Wook;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1708-1710
    • /
    • 2007
  • 댐 및 저수지 운영에 필수 요소인 수위 데이터의 신뢰성을 높일 수 있도록 수위측정에 가장 많이 사용되고 있는 부자식, 초음파식, 레이다식 수위계의 특성시험이 가능한 표준시험장치와 표준시험장치에 대한 운영의 일관성을 확보하기 위한 표준시험절차를 개발하였다. 또한, 표준시험장치의 최고측정능력을 산출하여 수위계 시험에 따른 불확도를 산출할 수 있도록 수위 측정 모델식을 제시하여 합성불확도1.408 mm와 확장불확도 3 mm를 각각 얻었다. 본 연구에서 제시된 최고측정능력은 수위데이터의 신뢰성 있는 자료 확보와 일관성 있는 자료관리가 가능하도록 품질관리 기반을 구축하였다.

  • PDF

A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC (HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정)

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.152-159
    • /
    • 2008
  • The purpose of this study was to determine the accurate quantification of vitamin A in infant formula by comparing two different standard stock solutions as well as various sample weights using high performance liquid chromatography. The sources of uncertainty in measurement, such as sample weight, final smaple vloume, and the instrumental results, were identified and used as parameters to determine the combined standard uncertainty based on GUM(guide to the expression of uncertainty in measurement) and the Draft EURACHEM/CITAC Guide. The uncertainty components in measuring were identified as standard weight, purity, molecular weight, dilution of the standard solution, calibration curve, recovery, reproducibility, sample weight, and final sample volume. Each uncertainty component was evaluated for type A and type B and included to calculate the combined uncertainty. The analytical results and combined standard uncertainties of vitamin A according to the two different methods of stock solution preparation were 627 ${\pm}$ 33 ${\mu}$g R.E./100 g for 1,000 mg/L of stock solution, and 627 ${\pm}$ 49 ${\mu}$g R.E./100 g for 100 mg/L of stock solution. The analytical results and combined standard uncertainties of vitamin A according to the various sample weighs were 622 ${\pm}$ 48 ${\mu}$g R.E./100 g, 627 ${\pm}$ 33 ${\mu}$g R.E./100 g, and 491 ${\pm}$ 23 ${\mu}$g R.E./100 g for 1 g, 2 g, and 5 g of sampling, respectively. These data indicate that the preparation method of standard stock solution and the smaple amount were main sources of uncertainty in the analysis results for vitamin A. Preparing 1,000 mg/L of stock solution for standard material sampling rather than 100 mg, and sampling not more than 2 g of infant formula, would be effective for reducing differences in the results as well as uncertainty.

Uncertainty Analysis of Spinning Rotor Gauge Calibrated by High Vacuum Standard of Static Expansion Method (정적법 고진공표준기에 의해 교정한 스피닝 로터 게이지 불확도 평가)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.186-194
    • /
    • 2005
  • A Spinning Rotor Gauge was calibrated between $4.04\times10^{-3}$ Pa and $1.11\times10^{-2}$ Pa at the high vacuum standard by static expansion method. The results were analysed according to the document of 'Guide to the Expression of Uncertainty in Measurement' of ISO. The expanded uncertainty was $3.0035\times10^{-3}$ Pa at $7.5448\times10^{-3}$ Pa. $95\%$ confidence level, and coverage factor of k = 1.

Estimation of Measurement Uncertainty for the HPLC Analysis of Deoxynivalenol in Wheat (밀에서 HPLC에 의한 데옥시니발레놀 분석의 측정불확도 산정)

  • Ok, Hyun-Ee;Chang, Hyun-Joo;Ahn, Jang-Hyuk;Cho, Jae-Young;Chun, Hyang-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.258-264
    • /
    • 2009
  • The principal objective of this study was to estimate the measurement uncertainty associated with determination of deoxynivalenol (DON), a mycotoxin generated by Fusarium strain, in food. In service of this goal, wheat as a food matrix was analyzed via high performance liquid chromatography-ultraviolet (HPLC-UV) detection using an immunoaffinity column for clean-up. The uncertainty sources in the measurement process were identified by sample weight, final volume, and sample concentration in extraction volume with components including standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. The expanded uncertainty for DON at a concentration of 300 ${\mu}g/kg$ was estimated as 71.62 ${\mu}g/kg$ using a coverage factor of two, which provides a confidence level of approximately 95%. The most influential component in the uncertainty sources was the recovery of the wheat matrix, followed by the calibration curve. These results indicate that all efforts may be directed toward reducing the uncertainties of the recovery of the wheat matrix and the calibration curve to obtain a reliable HPLC-UV method for DON analysis in wheat.

Uncertainties in Pressure Calibration of Laboratory Standard Microphones by Reciprocity Technique (가역방법에 의한 표준 마이크로폰 음압교정의 불확도)

  • 서상준;권휴상;이용봉;서재갑
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.90-102
    • /
    • 2004
  • According to the Mutual Recognition Arrangement (MRA), the calibration and/or test laboratories should satisfy the management and technical requirements ISO 17025 or equivalent. Chapter 5, Section 5.10.4 of the technical requirement of ISO 17025 suggests the required informations for calibration certificates, one of them is to state the uncertainty of measurement. The uncertainties of measurement in reciprocity calibration of standard laboratory microphone were calculated. The expanded uncertainties for 1 and 1/2 inch microphones were 0.03 dB in the middle frequency range and they increased up to 0.10 dB and 0.11 dB at 20 Hz, 0.07 dB and 0.08 dB at high frequency, respectively.